| Parameter Sistem | Kelas Arus Nominal In(A) | 63, 125, 160(W25), 250, 400, 630, 800(W630), 1000(W800), 1250, 1500 |
| Arus Nominal (An), 40℃ | 10,16,20,25,32,40,50,63; 10,16,20,25,32,40,50,63,125; 160,25,32,40,50,63,80,100,160; W125,25,32,40,50,63,80,100,125; 125,140,160,180,200,225,250; 250,280,315,320,350,400; 400,500,630; 800,630,700,800,W630,630; 1000,600,900,1000,1000,800,900,800; 1000,1250; 1000,1250,1600 |
| Tegangan Isolasi Nominal UI(V) | 800, 800, 800, 800, 1000, 1000, 1000, 1000, 1000, 1000 |
| Tegangan Tahan Impuls Nominal Uimp(kV) | 8, 8, 8, 8, 12, 12, 12, 12, 12, 12 |
| Tegangan Kerja Nominal Ue(V), AC 50/60Hz | 230/240,400/415,500; 230/240,400/415,500,690; 230/240,400/415,500,690; 230/240,400/415,500,690; 230/240,400/415,500,690; 230/240,400/415,500,690; 230/240,400/415,500,690; 230/240,400/415,500,690; 230/240,400/415,500,690; 230/240,400/415,500,690 |
| Kode Kemampuan Pemutusan | S, H, H, H, S, H, S, H, S, H |
| Jumlah Pole | 2P, 3P, 4P |
| Kemampuan Pemutusan Kondisi Maksimum Icu(kA) | AC230/240V: 36, 75, 36, 75, 50, 75; AC400/415V: 25, 50, 25, 50, 36, 36; AC500V: 25, -, 25, -, 30, 30; AC690V: 8, 10, 8, 10, 10, 10 |
| Kemampuan Pemutusan Operasional Ics(kA) | AC230/240V: 18, 50, 18, 50, 30, 50; AC400/415V: 15, 36, 15, 36, 36, 36; AC500V: 15, 36, 15, 36, 36, 36; AC690V: 7.5, 10, 7.5, 10, 13, 15, 12.5, 20, 20 |
| Standar yang Dituju | IEC/EN 60947-2, GB/T 14048.2; IEC/EN 60947-2, GB/T 14048.2 |
| Kategori Penggunaan | A, A, A, A, A, A, A, A, A, A |
| Fungsi Isolasi (Berlaku untuk produk B, C) | ■, ■, ■, ■, ■, ■, ■, ■, ■, ■ |
| Cara Koneksi | masuk atas keluar bawah, masuk atas keluar bawah |
| Suhu Kerja yang Disarankan | -35℃~70℃, -35℃~70℃ |
| Jarak Terbang (mm) | ≤50, ≤50, ≤50, ≤50, ≤100, ≤100, ≤100, ≤100, ≤100, ≤100 |
| Kapasitas Mekanis (kali) | tanpa perawatan dengan perawatan: 20000, 20000, 20000, 20000, 10000, 8000, 5000, 5000, 5000, 5000; 40000, 40000, 40000, 40000, 10000, 10000, 10000, 10000, 10000, 10000; 10000, 10000, 10000, 10000, 8000, 5000, 2500, 2500, 2500, 2500 |
| Umur Listrik (kali) | AC415V, In: 10000, 10000, 10000, 10000, 8000, 5000, 2500, 2500, 2500, 2500 |
| Karakteristik Kinerja | Cara Koneksi dan Jenis Perlindungan | Pemutusan listrik: perlindungan distribusi, perlindungan motor, perlindungan generator; Pemutusan anti-koneksi: perlindungan distribusi, perlindungan motor, perlindungan generator |
| Aksesori | kontak bantuan, kontak peringatan, pemutus terpisah, pemutus tegangan rendah, mekanisme operasi manual, mekanisme operasi listrik, koneksi papan belakang, plug-in, kunci, papan penghalang fase, khusus meter prabayar, alarm kelebihan beban tanpa pemutusan |