NW5 Series Modular Power Quality Power Units

Product category:
active filter
Product code:
P-227
Model:
NW5

Function & Use (Application Scenarios)

Distribution appliances and power quality products are mainly suitable for power systems with NW5 series power quality power units suitable for AC 50/60Hz and rated voltage AC690V or below. The product integrates multiple core functions of harmonic control, reactive power compensation, and three-phase unbalance control.

Surprise on inquiry

Product highlights

  • Harmonic control capabilities
  • Reactive power compensation support
  • Three-phase unbalance control
  • Intelligent communication support
  • Modular design

Model

NW5

Main Product Parameters

ClassificationPower quality monitoring and management deviceSecondary classificationactive filter
parametersRated voltage: 220V/400V/480V/690V; Noise index: ≤65dB; Full response time: ≤10ms; Communication interface: RS485Advantages/core features01 Flexible adjustment; both SVG and APF have reactive power compensation, harmonic control, and three-phase unbalance control capabilities. The priority can be set independently, and the governance function is more powerful. The compensation function can be flexibly adjusted according to the site conditions; 02 The product performance is better; the overall machine efficiency is up to 97.5%, the product performance is better, and the use is more energy-saving. Under full power operation, the annual power loss of a single module can be reduced by up to 4000+kwh; 03 Multi-scenario adaptation; multiple voltage specifications (220~690V) optional; two frequency (50/60Hz) adaptation, more optional specifications, suitable for more application scenarios

Product details

Function and use

NW5 series power quality power units are suitable for power systems with AC 50/60Hz and rated voltage AC690V or less. The product integrates multiple core functions of harmonic control, reactive power compensation, and three-phase unbalance control. It can accurately detect and filter out grid harmonics from 2 to 50 times, with a harmonic compensation rate of more than 95%. It can quickly track changes in load reactive power, increase the power factor to more than 0.99, and effectively balance three-phase currents, completely solving the problem of power pollution caused by nonlinear loads.

Detailed description

Parameters:
Rated voltage: 220V/400V/480V/690V
Noise index: ≤65dB
Full response time: ≤10ms
Communication interface: RS485

Advantages/core functions:
01 Flexible adjustment
SVG, APF Both have reactive power compensation, harmonic control, and three-phase unbalance control capabilities. The priority can be set independently, and the management function is more powerful. The compensation function can be flexibly adjusted according to the site conditions
02 The product performance is better
The overall machine efficiency is up to 97.5%, the product performance is better, and the use is more energy-saving. Under full power operation, the annual power loss of a single module can be reduced by up to 4000+kwh
03 Multi-scenario adaptation
A variety of voltage specifications (220~690V) optional; two frequencies (50/60Hz) adaptation, more optional specifications, adaptable to more application scenarios

Detailed parameters

Parameter table 1

< tr>< /tr>
Parameter classificationParameter itemParameter value
System ParametersProduct modelNW5APF
Rated input line voltage220V (-20%~+20%), 400 V(-40%~+20%), 480V(-20%~+15%), 690V(-30%~+15%)
Power grid frequency50Hz (±5% )
Overall efficiency≥97%
Current transformerSecondary rated current 5A
CT Wiring methodLoad side, source side
Circuit topologyThree-level
Performance indicatorsPhase rated compensation capacity220V/400V: 50/75/100/150A 480V/690V: 50/100A
Reactive power compensationSupport
Harmonic elimination Support
Three-phase unbalanced managementSupport
Filter range2~50 Times
Filtering times selection2~50 Times
Filter compensation rate≥95%
Full response time10ms
Control algorithmIntelligent FFT, instantaneous reactive power
Cooling methodIntelligent air cooling (automatic fan speed adjustment)
Noise index≈65dB (environmental noise 40dB, 1m away from the product) , single product noise)
CommunicationCommunication interfaceRS485
Communication protocolModbus
Protection function System voltage overvoltage and undervoltage protectionSupported
Compensated output overcurrent protectionSupported
Compensated output overcurrent protectionSupported
Over-temperature protectionSupported
DC bus overvoltage and undervoltage protectionSupported
Control system failureSupported
Main circuit device damage protectionSupported
Automatic detection of voltage and current phase sequenceSupported
Fault recordSupported 500 Strip
InstallationInstallation methodRack-mounted/wall-mounted
Ventilation volume of a single product220V/400V/480V: 1 50A:8.80m³/min; 100A/75A:9.54m³/min; 50A:10.2m³/min
690V: 50A/100A: 19.2m³/min

Parameter table 2

Parameter classificationParameter itemParameter value
System parameter Product modelNW5SVG
Rated input line voltage220V(-20%~+20%), 400V(-4 0%~+20%), 480V(-20%~+15%), 690V(-30%~+15%)
Grid frequency50Hz/60Hz (±2% )
Overall efficiency≥97.5%
Current transformerSecondary rated current 5A
CT Wiring methodLoad side, power side
Circuit topologyThree-level
Performance indexPhase line rated compensation capacity< /td>220V/400V: 50kvar, 100kvar
480V/690V: 80kvar, 120kvar
Number of filters2~13 Times
Three-phase unbalance managementSupport
Full response time5ms
Target power factor-1~+1 Adjustable
Control algorithmIntelligent FFT, instantaneous reactive power algorithm
Cooling methodIntelligent air cooling (automatic fan speed adjustment)
Noise index≈65dB (environmental noise ≤40dB, 1m away from the product) , single product noise)
CommunicationCommunication interfaceRS485
Communication protocolModbus
Protection functionSystem voltage overvoltage and undervoltage protectionSupport
Compensation output automatic current limitSupport
Compensation output over-current protectionSupported
Over-temperature protectionSupported
DC side overvoltage and undervoltage protectionSupport
Control system failure Support
Main circuit device damage protectionSupport
Automatic detection of voltage and current phase sequenceSupported
Fault recordSupported
InstallationInstallation methodRack-mounted/wall-mounted

Requirement confirmation

Application, rating, quantity and drawings are checked first.

Factory matching

Supplier capacity, certificates and production slot are reviewed.

Order transaction

Confirm commercial terms, sign the commercial contract, and confirm the related document checklist.

Shipment control

Packing photos, inspection records and delivery status are tracked.