NXMNLE series transparent shell residual current action circuit breaker

Product category:
Molded case circuit breaker
Product code:
P-264
Model:
NXMNLE

Function & Use (Application Scenarios)

Distribution appliances and plastic case circuit breaker products are mainly suitable for NXMNLE series residual current action circuit breakers. Their main functions are to provide indirect contact protection against fatal personal electric shocks and to provide protection against electrical fires caused by ground fault current, such as insulation damage.

Surprise on inquiry

Product highlights

  • Reliable overload protection
  • Short circuit protection capability
  • Leakage protection support
  • Engineering application adaptation
  • Stable and reliable operation

Model

NXMNLE

Main Product Parameters

ClassificationswitchgearSecondary classificationMolded case circuit breaker

Product details

Function and use

NXMNLE series residual current operated circuit breaker series, its main function is to provide indirect contact protection against fatal personal electric shock, and to provide protection against electrical fires caused by ground fault current, such as insulation damage, etc. It also provides protection against overload, short circuit and under-voltage of the line, and can also be used for infrequent switching of the line.

Detailed parameters

< tbody>3P
Parameter classificationParameter itemParameter value
Product modelNXMNLLE-12510-16-32-40-50-63-80-100-125
NXMNLLE-W12516-32-40-50-63-80-100-125
NXMNLLE-16020-32-40-50-63-80-100-125-160
Electrical performanceRated insulation voltage Ui (V)800
Rated impulse withstand voltage Uimp (kV)8
Rated operating voltage Ue(V),AC 50/60Hz220/230/240V (2P applicable), 380/400/415
Number of poles2P
4P
Breaking capacityS
Rated limit short circuit breaking capacity Icu(kA)AC220/230/240V: 36, AC380/400/415V: 25
AC220/230/240V: 50, AC380/400/415V: 36
AC220/230/240V: 50, AC380/400/415V: 36
Rated operating short-circuit breaking capacity Ics(kA)AC220/230/240V: 18, AC380/400/415V: 15
AC220/230/240V: 30, AC380/400/415V: 18
AC220/230/240V: 30, AC380/400/415V: 18
Power-on indication
Leakage alarm does not trip
Comply with standardsIEC/EN 60947-2, GB/T 14048.2
Use categoryA
Working environment temperature (℃)-25~+70
Isolation function ①
Wiring methodUpstream cable entry
Flashover distance (mm)≤ 50
Mechanical life (times)Maintenance-free: 40000, with maintenance: 20000
Maintenance-free: 40000, with maintenance: 20000 20000
Maintenance-free: 40000, with maintenance: 20000
Electrical life (times)AC45V, In: 10000
AC45V,In: 10000
AC45V,In: 10000
Installation methodFront of the board: ■, Auxiliary: ■, Alarm: ■, Auxiliary alarm: ■, Undervoltage: ■, Leakage alarm trip/no trip: ■
Internal accessories
External accessoriesArc isolation plate
Terminal cover
Connection plate
Manual operation
Handle lock
Outline dimensions (mm) Height (H) × Width (W) × Depth (D) 2P: 155*52*62, 3P: 155*75*62, 4P: 155*100*62 160*92*72, 4P: 160*122*72
2P: 160*62*72, 3P: 160*92*72, 4P: 160*122*72
Phase distance (mm)25
30
30
Note: 1. The isolation function is not applicable to new circuit breakers with 4A/4D poles.

Requirement confirmation

Application, rating, quantity and drawings are checked first.

Factory matching

Supplier capacity, certificates and production slot are reviewed.

Order transaction

Confirm commercial terms, sign the commercial contract, and confirm the related document checklist.

Shipment control

Packing photos, inspection records and delivery status are tracked.