| System parameters | Rated voltage level In(A) | 63, 125, 160, 250, 400, 630, 800, 1000, 1250, 1600 |
| Rated current (A), 40℃ | 10,16,20,25,32,40,50,63; 10,16,20,25,32,40,50,63; 63,80,100,125; 63,80,100,125; 125,140,160,180; 125,140,160,180; 250,280,315,320,350,400; 400,500,630; 630,700,800; 800,900,1000; 1000,1250,1600 |
| Rated insulation voltage Ui (V) | 800, 800, 800, 800, 1000, 1000, 1000, 1000, 1000, 1000 |
| Rated impulse withstand voltage Uimp(kV) | 8, 8, 8, 8, 12, 12, 12, 12, 12, 12 |
| Rated operating voltage Ue(V), AC 50/60Hz | 230/240,400/415,500; 230/240,400/415,500; 230/240,400/415,500,690; 230/240,400/415,500,690; 230/240,400/415,500,690; 230/240,400/415,500,690; 230/240,400/415,500,690; 230/240,400/415,500,690; 230/240,400/415,690 |
| Resolution code | S, H, S, H, S, H, S, H, S, H |
| Number of poles | 2P, 3P, 4P |
| AP | - - - - - - - - - - |
| Rated short-circuit breaking capacity Icu (kA) | AC230/240V: 36, 75, 75, 75, 75; AC400/415V: 25, 50, 50, 50, 50; AC500V: - - 25, - -; AC690V: - - - 8, 10 |
| Rated operating short-circuit breaking capacity Ics (kA) | AC230/240V: 18, 50, 50, 50, 50; AC400/415V: 15, 36, 36, 36, 36; AC500V: - - 15, - -; AC690V: - - 4, 5, 5 |
| Comply with standards | IEC/EN 60947-2-, GB/T 14048.2 |
| Use category | A, A, A, A, A, A, A, A, A, A |
| Isolating switch (applicable to B/C type products) | ■ ■ ■ ■ ■ ■ ■ ■ ■ |
| Operation method | Up in and out, top in and out, top in and out, top in and out, top in and bottom out, top in and bottom out, top in and bottom out, top in and bottom out, top in and bottom out, Top in and bottom out |
| Applicable ambient temperature | -35℃~+70℃, -35℃~+70℃, -35℃~+70℃, -35℃~+70℃, -35℃~+70℃, -35℃~+70℃, -35℃~+70℃, -35℃~+70℃, -35℃~+70℃, -35℃~+70℃ |
| Arc distance (mm) | ≤550, ≤150, ≤50, ≤50, ≤100, ≤100, ≤100, ≤100, ≤100, ≤100 |
| Mechanical life (times) | Without maintenance: 20000, 20000, 20000, 20000, 10000, 10000, 8000, 5000, 5000, 5000; With maintenance: 40000, 40000, 40000, 40000, 20000, 20000, 20000, 20000, 20000, 20000 |
| Electrical life (times) | AC415V, In: 10000, 10000, 10000, 10000, 8000, 8000, 5000, 2500, 2500, 2500 |
| Performance indicators | Tripping method and protection type | Electromagnetic tripping: distribution protection, motor protection, Generator protection, generator protection; thermal magnetic tripping: distribution protection, motor protection, generator protection, generator protection |
| Accessories | Auxiliary contacts, alarm contacts, shunt releases, undervoltage releases, manual operating mechanisms, terminal blocks, plug-in type, coupling plate, adjacent panel, dedicated for preset zero meters, Overload relay without tripping |
| Outline dimensions (mm) | Width (2P/3P/4P): 56/78/103, 56/78/103, 63/90/129, 78/105/140, /-140/185, /-182/240, /-210/280, /-210/280, /-210/280 |
| High | 135, 135, 155, 165, 257, 257, 270, 280, 370, 370 |
| Deep (S/H type) | 71/81, 71/81, 75.5/91, 77/102, 108.5/108.5, 108.5/108.5, 114/114, 118/118, 153/153, 1600A:158/156; <1600A:133/153 |