| System parameters | Rated grade rated current Iin(A) | 63, 125, 160(W25), 250, 400, 630, 800(W630), 1000(W800), 1250, 1500 |
| Rated current (An), 40℃ | 10,16,20,25,32,40,50,63; 10,16,20,25,32,40,50,63,125; 160,25,32,40,50,63,80,100,160; W125,25,32,40,50,63,80,100,125; 125,140,160,180,200,225,250; 250,280,315,320,350,400; 400,500,630; 800,630,700,800,W630,630; 1000,600,900,1000,1000,800,900,800; 1000,1250; 1000,1250,1600 |
| Rated ultimate voltage UI(V) | 800, 800, 800, 800, 1000, 1000, 1000, 1000, 1000, 1000 |
| Rated impulse withstand voltage Uimp (kV) | 8, 8, 8, 8, 12, 12, 12, 12, 12, 12 |
| Rated operating voltage Uimp (V), AC 50/60Hz | 230/240,400/415,500; 230/240,400/415,500,690; 230/240,400/415,500,690; 230/240,400/415,500,690; 230/240,400/415,500,690; 230/240,400/415,500,690; 230/240,400/415,500,690; 230/240,400/415,500,690; 230/240,400/415,500,690 |
| Breaking capacity code | S, H, H, H, S, H, S, H, S, H |
| Number of poles | 2P, 3P, 4P |
| Rated ultimate short-circuit breaking capacity Icu(kA) | AC230/240V: 36, 75, 36, 75, 50, 75; AC400/415V: 25, 50, 25, 50, 36, 36; AC500V: 25, -, 25, -, 30, 30; AC690V: 8, 10, 8, 10, 10, 10 |
| Rated operating short-circuit breaking capacity Ics (kA) | AC230/240V: 18, 50, 18, 50, 30, 50; AC400/415V: 15, 36, 15, 36, 36, 36; AC500V: 15, 36, 15, 36, 36, 36; AC690V: 7.5, 10, 7.5, 10, 13, 15, 12.5, 20, 20 |
| Compliant with standards | IEC/EN 60947-2, GB/T 14048.2; IEC/EN 60947-2, GB/T 14048.2 |
| Usage Category | A, A, A, A, A, A, A, A, A, A |
| Isolation function (applicable to B, C type products) | ■, ■, ■, ■, ■, ■, ■, ■, ■, ■ |
| Wiring method | Top in and bottom out, Top in and bottom out |
| Applicable working temperature | -35℃~70℃, -35℃~70℃ |
| Arc distance (mm) | ≤50, ≤50, ≤50, ≤50, ≤100, ≤100, ≤100, ≤100, ≤100, ≤100 |
| Machine capacity (times) | Maintenance-free and maintenance-free: 20000, 20000, 20000, 20000, 10000, 8000, 5000, 5000, 5000, 5000; 40000, 40000, 40000, 40000, 10000, 10000, 10000, 10000, 10000, 10000; 10000, 10000, 10000, 10000, 8000, 5000, 2500, 2500, 2500, 2500 |
| Electrical life (times) | AC415V, In: 10000, 10000, 10000, 10000, 8000, 5000, 2500, 2500, 2500, 2500 |
| Performance indicators | Connector mode and protection type | Electric connection tripping: distribution protection, motor protection, generator protection; anti-connection tripping: distribution protection, motor protection, Generator protection |
| Accessories | Auxiliary contacts, alarm contacts, separation releases, undervoltage releases, manual operating mechanisms, electric operating mechanisms, behind-the-board wiring, plug-in, interlocking, phase partitions, dedicated for prepayment meters, overload alarm does not trip |