NM1 series plastic case circuit breaker

Product category:
Molded case circuit breaker
Product code:
P-272
Model:
NM1

Function & Use (Application Scenarios)

Distribution appliances and plastic case circuit breaker products are mainly suitable for rated insulation voltage of the circuit breaker to 800V (NM1-63 type is 500V), suitable for AC 50Hz, rated working voltage to 690V (NM1-63 type is 400V), rated working current

Surprise on inquiry

Product highlights

  • Reliable overload protection
  • Short circuit protection capability
  • Engineering application adaptation
  • Stable and reliable operation
  • Easy system integration

Model

NM1

Main Product Parameters

ClassificationswitchgearSecondary classificationMolded case circuit breaker

Product details

Function and purpose

This circuit breaker has a rated insulation voltage of 800V (NM1-63 type is 500V), is suitable for AC 50Hz, a rated operating voltage of 690V (NM1-63 type is 400V), and a rated operating current of 10A to 1250A in distribution network circuits. It is used to distribute electric energy and protect lines and power equipment from overload, short circuit, undervoltage and other faults.

Detailed parameters

Parameter table 1

240V/415V/690V
Parameter classificationParameter itemParameter value
4.1 Rating of circuit breaker (see table 2)ModelNM1-63S
Frame rating rated current (A)63
Rated operating voltage Ue(V)240/415
Rated insulation voltage Ui(V)800
Rated impulse withstand voltage Uimp (kV) 818/13/-
Maintainable mechanical life (times)20000
Electrical life AC400V (times)3000
Number of poles3, 4
Arc distance (mm)≤50
ModelNM1-63H
Frame grade rated current (A)63
Rated operating voltage Ue(V)400
Rated insulation voltage Ui(V)500
Rated impulse withstand voltage Uimp (kV)8
Rated ultimate short-circuit breaking capacity (kA) 240V/415V/690V-/50+/-
Rated operating short-circuit breaking capacity (kA) 240V/415V/690V-/25+/-
Maintainable mechanical life (times)20000
Electrical life AC400V (times)3000
Number of poles2, 3, 4
Arc distance (mm)≤50
ModelNM1-125S
Frame rating rated current (A)125
Rated operating voltage Ue(V)240/415/690
Rated insulation voltage Ui(V)800
Rated impulse withstand voltage Uimp (kV)8
Rated ultimate short-circuit breaking capacity (kA) 240V/415V/690V50/35/8
Rated operating short-circuit breaking capacity (kA) 240V/415V/690V30/18/4
Maintainable mechanical life (times)20000
Electrical life AC400V (times)3000
Number of poles2, 3, 4
Arc distance (mm)≤50
ModelNM1-125H
Frame rating rated current (A)125
Rated operating voltage Ue(V)400/690
Rated insulation voltage Ui(V)800
Rated impulse withstand voltage Uimp (kV)8
Rated ultimate short-circuit breaking capacity (kA) 240V/415V/690V-/50/10
Rated operating short-circuit breaking capacity (kA) 240V/415V/690V-/25/5
Maintainable mechanical life (times)20000
Electrical life AC400V (times)3000
Number of poles2, 3, 4
Arc distance (mm)≤50
ModelNM1-125R
Frame rating rated current (A)125
Rated operating voltage Ue(V)400/690
Rated insulation voltage Ui(V)800
Rated impulse withstand voltage Uimp (kV)8
Rated ultimate short-circuit breaking capacity (kA) 240V/415V/690V-/85/20
Rated operating short-circuit breaking capacity (kA) 240V/415V/690V-/42.5/10
Maintainable mechanical life (times)20000
Electrical life AC400V (times)3000
Number of poles3
Arc distance (mm)≤50
ModelNM1-250S
Frame rating rated current (A)250
Rated operating voltage Ue(V)240/415/690
Rated insulation voltage Ui(V)800
Rated impulse withstand voltage Uimp (kV)8
Rated ultimate short-circuit breaking capacity (kA) 240V/415V/690V50/35/8
Rated operating short-circuit breaking capacity (kA) 240V/415V/690V30/18/4
Maintainable mechanical life (times)20000
Electrical life AC400V (times)3000
Number of poles2, 3, 4
Arc distance (mm)≤50
ModelNM1-250H
Frame rating rated current (A)250
Rated operating voltage Ue(V)125, 160, 200, 225, 250
Rated insulation voltage Ui(V)400/690
Rated impulse withstand voltage Uimp (kV)8
Rated ultimate short-circuit breaking capacity (kA) 240V/415V/690V-/50/10
Rated operating short-circuit breaking capacity (kA) 240V/415V/690V-/25/5
Maintainable mechanical life (times)20000
Electrical life AC400V (times)3000
Number of poles2, 3, 4
Arc distance (mm)≤50
ModelNM1-250R
Frame rating rated current (A)250
Rated operating voltage Ue(V)125, 160, 200, 225, 250
Rated insulation voltage Ui(V)400/690
Rated impulse withstand voltage Uimp (kV)8
Rated ultimate short-circuit breaking capacity (kA) 240V/415V/690V-/85/20
Rated operating short-circuit breaking capacity (kA) 240V/415V/690V-/42.5/10
Maintainable mechanical life (times)20000
Electrical life AC400V (times)3000
Number of poles3

Parameter table 2

Parameter classificationParameter itemParameter value
4.4 Instantaneous operating characteristics of distribution circuit breaker (see Table 5)Frame rating rated current Inm(A)63
Rated current In(A)10~63
Short-circuit protection current setting methodFixed
Short-circuit protection current setting value li(A) And tolerance10In, ±20%
Unipolar short-circuit protection current action setting value li(A)12In
Tripping time (s)<0.2
Frame rating rated current Inm(A)125
Rated current In(A)16~125
Short-circuit protection current setting methodFixed
Short-circuit protection current setting value li(A) And tolerance10In, ±20%
Single-pole short-circuit protection current action setting value li(A)12In
Frame grade rated current Inm(A)250
Rated current In(A)100~250
Short-circuit protection current setting methodFixed
Short-circuit protection current setting value li(A) And tolerance10In, ±20%
Single-pole short-circuit protection current action setting value li(A)12In
Frame grade rated current Inm(A)400
Rated current In(A)225~400
Short-circuit protection current setting methodFixed
Short-circuit protection current setting value li(A) And tolerance10In, ±20%
Single-pole short-circuit protection current action setting value li(A)12In
Frame grade rated current Inm(A)630
Rated current In(A)400~630
Short-circuit protection current setting methodFixed
Short-circuit protection current setting value li(A) And tolerance10In, ±20%
Single-pole short-circuit protection current action setting value li(A)12In
Frame grade rated current Inm(A)800
Rated current In(A)630~800
Short-circuit protection current setting methodFixed
Short-circuit protection current setting value li(A) And tolerance10In, ±20%
Single-pole short-circuit protection current action setting value li(A)12In
Frame grade rated current Inm(A)1250
Rated current In(A)800~1250
Short-circuit protection current setting methodFixed
Short-circuit protection current setting value li(A) And tolerance7In, ±20%
Single-pole short-circuit protection current action setting value li(A)10In
4.5 Instantaneous operating characteristics of circuit breaker for motor protection (see Table 6)Frame rating rated current Inm(A)63
Rated current In(A)10~63
Short-circuit protection current setting methodFixed
Short-circuit protection current setting value li(A) And tolerance12In, ±20%
Unipolar short-circuit protection current action setting value li(A)14In
Tripping time (s)<0.2
Frame rating rated current Inm(A)125
Rated current In(A)16~125
Short-circuit protection current setting methodFixed
Short-circuit protection current setting value li(A) And tolerance12In,±20%
Single-pole short-circuit protection current action setting value li(A)14In
Frame grade rated current Inm(A)250
Rated current In(A)100~250
Short-circuit protection current setting methodFixed
Short-circuit protection current setting value li(A) And tolerance12In,±20%
Single-pole short-circuit protection current action setting value li(A)14In
Frame grade rated current Inm(A)400
Rated current In(A)225~400
Short-circuit protection current setting methodFixed
Short-circuit protection current setting value li(A) And tolerance12In,±20%
Single-pole short-circuit protection current action setting value li(A)14In
Frame grade rated current Inm(A)630
Rated current In(A)400~630
Short-circuit protection current setting methodFixed
Short-circuit protection current setting value li(A) And tolerance12In,±20%
Single-pole short-circuit protection current action setting value li(A)14In
Frame grade rated current Inm(A)800
Rated current In(A)630~800
Short-circuit protection current setting methodFixed
Short-circuit protection current setting value li(A) And tolerance12In,±20%
Unipolar short-circuit protection current action setting value li(A)14In

Requirement confirmation

Application, rating, quantity and drawings are checked first.

Factory matching

Supplier capacity, certificates and production slot are reviewed.

Order transaction

Confirm commercial terms, sign the commercial contract, and confirm the related document checklist.

Shipment control

Packing photos, inspection records and delivery status are tracked.