NM10 series plastic case circuit breaker

Product category:
Molded case circuit breaker
Product code:
P-273
Model:
NM10

Function & Use (Application Scenarios)

Distribution appliances and plastic case circuit breaker products are mainly suitable for distribution network circuits with AC 50Hz, rated operating voltage to 380V, and rated current to 600A that operate infrequently (hereinafter referred to as circuit breakers). They are used to distribute electric energy and protect lines and power supplies.

Surprise on inquiry

Product highlights

  • Reliable overload protection
  • Short circuit protection capability
  • Engineering application adaptation
  • Stable and reliable operation
  • Easy system integration

Model

NM10

Main Product Parameters

ClassificationswitchgearSecondary classificationMolded case circuit breaker

Product details

Function and use

NM10 series plastic case circuit breakers (hereinafter referred to as circuit breakers) are mainly suitable for distribution network circuits with AC 50Hz, rated operating voltage to 380V, and rated current to 600A with infrequent operation. They are used to distribute electric energy and protect lines and power equipment from damage by overload, short circuit, undervoltage and other faults. Circuit breakers of 250A and below can also be used as infrequent starting and overload, short circuit and under-voltage protection of motors.

Detailed parameters

< td>
Parameter classificationParameter itemParameter value
Test current nameInitial stateCold state
< /td>Hot
I/In1.05
1.30
Appointed timeInm=100 (A)
In ≤ 63
63
250
< /td>600
1h
2h
2h
2h
Serial numberTest current nameSetting current (I/In)
1Agreed non-tripping current1.0
2Agreed tripping current1.2
3Returnable Current7.2
Appointed time2h
2h
≤ 10S
Initial stateCold state
Follow sequence 1 Start after test
——
Model numberInstantaneous operating current setting value I(A) and tolerance of distribution circuit breaker Motor protection circuit breaker instantaneous operating current setting value I(A) And tolerance
NM10-100, NM10-100H10In,±20%12In,±20%
NM10-25010In, ±20%12In,±20%
NM10-60010In,±20%-
Single-pole short-circuit protection current action setting value I(A)14In (for power distribution) 17In (for motor protection)
Tripping time (s)<0.2
ModelFrame grade rated current (Inm A)Rated operating voltage (Ue V) Rated insulation voltage (Ui V) Rated frequency (Hz) Rated ultimate short-circuit breaking capacity Icu kA 380V Rated operating short-circuit breaking capacity Ics kA 380V Arcing distance mm Rated current (In A)
NM10-100100380 380 50 15 7.5 150 20, 30, 40, 50, 60, 80, 100
NM10-100H100380 380 50 15 10 150 20, 30, 40, 50, 60, 80, 100
NM10-250250380 380 50 20 12.5 200 120, 150, 170, 200, 250
NM10-600600380 380 50 30 15 200 300, 400, 500, 600

Requirement confirmation

Application, rating, quantity and drawings are checked first.

Factory matching

Supplier capacity, certificates and production slot are reviewed.

Order transaction

Confirm commercial terms, sign the commercial contract, and confirm the related document checklist.

Shipment control

Packing photos, inspection records and delivery status are tracked.