DZ15 series plastic shell circuit breaker

Product category:
Molded case circuit breaker
Product code:
P-275
Model:
DZ15

Function & Use (Application Scenarios)

Distribution appliances and plastic case circuit breaker products are mainly suitable for (hereinafter referred to as circuit breakers), suitable for circuits with AC 50Hz, rated voltage 380V, and rated current up to 100A. They are used for overload and short-circuit protection of power distribution and motors, and also for infrequent line switching.

Surprise on inquiry

Product highlights

  • Reliable overload protection
  • Short circuit protection capability
  • Engineering application adaptation
  • Stable and reliable operation
  • Easy system integration

Model

DZ15

Main Product Parameters

ClassificationswitchgearSecondary classificationMolded case circuit breaker

Product details

Function and use

DZ15 series plastic case circuit breaker (hereinafter referred to as circuit breaker) is suitable for circuits with AC 50Hz, rated voltage 380V, and rated current up to 100A. It is used for power distribution and motor overload and short-circuit protection. It is also used for infrequent line switching and infrequent starting of the motor.

Detailed parameters

Parameter table 1

Parameter classificationParameter itemParameter value
4.1 The technical parameters of the circuit breaker are shown in Table 1ModelDZ15-40, DZ15-100
Rated voltage Ue(V)380
Rated insulation voltage Ui(V)690
Frame grade rated current (A)40, 100
Number of poles2, 3
Rated current (A)32,40, 63,80, 100
Rated ultimate short-circuit breaking capacity (Icu kA)3, 5
Rated operating short-circuit breaking capacity (Ics kA)3, 2.5
Arc distance (mm)≤ 50, ≤ 70

Parameter table 2

< /tr>
Parameter classificationParameter itemParameter value
Protection typeOn-load operating conditionConnection
Ue 6in
0.17Ue 6in
0.35
Number of operating cyclesLoaded
1500
No load
8500
Total
1 0000
Number of operating cycles120/h
For distribution linesUe In
Ue In
0.8
1500
8500
10000
120/h
4.3 Protection characteristics of overcurrent release4.3.1 Protection characteristics of overcurrent release of circuit breaker for distribution protection (see Table 3)
Ambient air temperature+30±2℃
Test current / Rated current1.05
1.30
Test current / Rated currentIn>63A
In ≤ 63A
Initial stateCold start
Hot start
2h Internal tripping
1h Internal tripping
2h Internal tripping
1h Internal tripping
4.3.2 Protection performance of circuit breaker overcurrent release for motor protection (see table 4)
Ambient air temperature+20±2℃
Test current / Rated current1.0
1.2
Test time2h No tripping
2h Internal tripping
Initial stateCold state starting
Hot state starting
4.3.3 Instantaneous overcurrent release current setting value (see table 5)
Model numberDZ15-40
DZ15-100
Instantaneous operating current setting value of distribution circuit breaker Ii(A) and tolerance10In,±20%
Motor protection circuit breaker instantaneous operating current setting value Ii(A) and tolerance12In, ±20%
Single-pole short-circuit protection current operating setting value Ii(A)For power distribution: 12In
For motor protection: 14In (s)
<0.2
4.3.4 Protection characteristic curve of circuit breaker overcurrent releaseCharacteristic curve for distribution protection

Parameter table 3

Parameter classificationParameter itemParameter value
Protection functionAction timeFunctional relationship of rated current multiples (see graph)
InstallationRated current multiple range1 To 100 I/I_n
Performance indicatorsAction time range0.005 seconds to 10000 seconds

Requirement confirmation

Application, rating, quantity and drawings are checked first.

Factory matching

Supplier capacity, certificates and production slot are reviewed.

Order transaction