NM1B series plastic case circuit breaker

Product category:
Molded case circuit breaker
Product code:
P-276
Model:
NM1B

Function & Use (Application Scenarios)

Distribution appliances and plastic case circuit breaker products are mainly suitable for power distribution networks with rated insulation voltage of the circuit breaker up to 800V (400A frame to 1000V), AC 50Hz, rated working voltage up to 690V, and rated working current from 10A to 400A.

Surprise on inquiry

Product highlights

  • Reliable overload protection
  • Short circuit protection capability
  • Engineering application adaptation
  • Stable and reliable operation
  • Easy system integration

Model

NM1B

Main Product Parameters

ClassificationswitchgearSecondary classificationMolded case circuit breaker

Product details

Function and use

This circuit breaker has a rated insulation voltage of 800V (400A frame to 1000V). It is suitable for distribution network circuits with AC 50Hz, rated operating voltage to 690V, and rated operating current from 10A to 400A. It is used to distribute power and protect lines and power equipment from damage by overload, short circuit, undervoltage and other faults.

Detailed parameters

25< tr>< /tr>Frame grade rated current (A)< td>Frame rating rated current (A) td>4.3 Inverse time limit breaking action characteristics of the overcurrent release of the circuit breaker for motor protection when all poles are energized at the same time (see Table 4)< td>Cold state td>
Parameter classificationParameter itemParameter value
4.1 Rating of circuit breaker (see Table 2)ModelNM1B-125S
Frame rating rated current (A)125
Rated current (A)10, 16, 20, 25, 32 , 40, 50, 63, 80, 100, 125
Rated operating voltage Ue(V)400
Rated insulation voltage Ui (V)800
Rated ultimate short-circuit breaking capacity (kA)
Rated operating short-circuit breaking capacity (kA)15
Machine Mechanical life (times)20000
Electrical life AC400V (times)3000
Number of poles3, 4
Arc distance (mm)≤50
Model numberNM1B-W125S
Frame rating rated current (A) 125
Rated current (A)63, 70, 75, 80, 90, 100, 110, 120, 125
Rated operating voltage Ue(V)400
Rated insulation voltage Ui(V) 800
Rated ultimate short-circuit breaking capacity (kA)35
Rated operating short-circuit breaking capacity (kA)17.5
Mechanical life (times)20000
Electrical life AC400V (times)3000
Number of poles3, 4
Arc distance (mm)≤50
Rated Working voltage Ue(V)690
Rated insulation voltage Ui(V)800
Rated ultimate short-circuit breaking capacity (kA)3
Rated operating short-circuit breaking capacity (kA)3
Model numberNM1B-160S
Frame grade Rated current (A)160
Rated current (A)63, 80, 100, 125, 140, 150, 160
Rated operating voltage Ue(V)400
Rated insulation Voltage Ui (V)800
Rated ultimate short-circuit breaking capacity (kA)35
Rated operating short-circuit breaking capacity (kA)17.5
Mechanical life (times) 20000
Electrical life AC400V (times)3000
Number of poles3, 4
Arc distance (mm)≤50
Rated operating voltage Ue(V)690
Rated insulation voltage Ui(V)800
Rated ultimate short-circuit breaking capacity (kA)3
Rated operating short-circuit breaking capacity (k A)3
Model numberNM1B-250S
250
Rated current (A)160, 180, 200, 225, 250
Rated operating voltage Ue(V)400
Rated insulation Voltage Ui (V)800
Rated limit short-circuit breaking capacity (kA)35
Rated operating short-circuit breaking capacity (kA)17.5
Mechanical life (times) 20000
Electrical life AC400V (times)3000
Number of poles3, 4
Arc distance (mm)≤50
Rated operating voltage Ue(V)690
Rated insulation voltage Ui(V)800
Rated ultimate short-circuit breaking capacity (kA)4
Rated operating short-circuit breaking capacity ( kA)4
Model numberNM1B-400S
400
Rated current (A)250, 315, 400
Rated operating voltage Ue(V)400
Rated insulation voltage Ui(V) 1000
Rated ultimate short-circuit breaking capacity (kA)35
< /td>Rated operating short-circuit breaking capacity (kA)17.5
Mechanical life (times)5000
Electrical life AC400V (times)1000
Number of poles3, 4
Arc distance (mm)≤100
4.2 Distribution circuit breaker Inverse time limit breaking action characteristics when all poles of the current release are energized at the same time (see Table 3)Serial number1
Test current nameAgreed no tripping current
I/In1.05
Appointed time2h (In>63A), 1h (In≤63A)
Initial stateCold state
Serial number2
Test current nameConventional tripping current
I/In1.30
Appointed time2h(I n>63A), 1h (In≤63A)
Initial stateStart immediately after test number 1
Serial number1
< /td>I/In1.0
Appointed time>2h
Initial stateCold state
Remarks
Serial number2
I/In1.2
Appointed time≤2h
Initial stateStart immediately after test number 1
Remarks10≤In≤25
Serial number3
I/In1.5
Appointed time≤2min
Initial stateHot state
Remarks30
Appointed time≤8min
Initial stateHot state
Serial number4
I/In7.2
Appointed time0.5s≤T≤5s
Initial status
Remarks10≤In≤25
Appointed time6s≤T≤20s
Initial stateCold state
Remarks30≤In≤400
4.4 Circuit breaker short-circuit protection current setting value (see Table 5)ModelNM1B-1 25S
Instantaneous operating current setting value II (A) and tolerance of distribution circuit breaker10In,±20%
The instantaneous operating current setting value II (A) and tolerance of the circuit breaker for motor protection12In, ±20%

Requirement confirmation

Application, rating, quantity and drawings are checked first.

Factory matching

Supplier capacity, certificates and production slot are reviewed.

Order transaction

Confirm commercial terms, sign the commercial contract, and confirm the related document checklist.

Shipment control

Packing photos, inspection records and delivery status are tracked.