Function & Use (Application Scenarios)

Power distribution appliances and residual current action circuit breakers are mainly suitable for CHINT circuits with AC 50/60Hz, rated voltage AC415V and below, and rated current 10A to 800A. Its main function is to provide indirect contact protection against fatal electric shock.

Surprise on inquiry

Product highlights

  • Reliable overload protection
  • Short circuit protection capability
  • Leakage protection support
  • Easy to install and maintain
  • Modular design

Model

NM5NELE

Main Product Parameters

ClassificationswitchgearSecondary classificationResidual current operated circuit breaker
Advantages/core features01 Excellent performance; it has AC type/A type leakage action protection characteristics; it can additionally protect situations containing DC pulsation leakage, such as charging piles, medical equipment, precision electronic equipment, etc.; the leakage current/delay time is adjustable in four levels, providing customers with a wider adjustment range and reducing replacement costs caused by capacity expansion; 02 Flexible and easy to use; the entire series of products can achieve free top/bottom cable entry; the industry-leading miniaturized design of accessories can install 4 types of accessories at the same time to meet a variety of extended functional requirements; 03 is easy to use; the accessories realize box-type modular installation, and the accessory shell is streamlined, easy to maintain and replace, and reduces the inventory of spare parts/spare parts

Product details

Function and use

Chint NM5NELE series residual current action circuit breakers are suitable for AC 50/60Hz, rated voltage AC415V and below, and rated current 10A to 800A circuits. Its main function is to provide indirect contact protection against fatal personal electric shock, to provide protection against electrical fires caused by ground fault current, such as insulation damage, and to provide protection against overload, short circuit and under-voltage of the line, and can also be used for infrequent switching of lines.

Detailed description

Advantages/core functions:
01 Excellent performance
With AC type/A type leakage action protection characteristics

Can provide additional protection for DC pulsating leakage situations, such as charging piles, medical equipment, precision electronic equipment, etc.

Leakage current/delay time is adjustable in four levels, providing customers with a wider adjustment range and reducing replacement costs caused by capacity expansion
02 Flexible and easy to use
The entire series of products can achieve free top/bottom cable entry

Industry-leading miniaturized design of accessories, 4 types of accessories can be installed at the same time, meeting a variety of extended functional requirements
03 Easy to use
The accessories realize box-type modular installation, the accessory frame is streamlined, easy to maintain and replace, and reduces the inventory of spare parts/spare parts

Detailed parameters

Parameter table 1

< td>Q< /tr>
Parameter classificationParameter itemParameter value
Product modelNM5NELE-125
System parameterRated operating current In(A),40℃25-32-40-50-63-80-100-125
Electrical performanceRated insulation resistance Ui(V)1000
Rated impulse withstand voltage Uimp(kV)8
Rated operating voltage Ue(V),AC50/60Hz380/400/415
Number of poles3P
4P(3P+N, 4P)
Breaking abilityF
R
Rated limit short circuit breaking capacity Icu(kA)AC380/400/415V 36
50
70
Rated operating short-circuit breaking capacity Ics(kA)AC380/400/415V 36
50
50
Communication indicationPower on indication
Leakage Alarm does not trip
Conforms to standardsIEC/EN60947-2GB/T14048 .2
Usage categoryA
Working environment temperature (℃)~-25~+70
Isolation function
Installation and connectionWiring methodUp/down free entry and exit lines
Flashover distance≤ 50/Zero flashover (need to install short sub-hood TCY)
Mechanical life (times)Maintenance-free 20000
With maintenance 40000
Electrical life (times)AC40/415V 10000
Protection typeDistribution protection
Motor protection
FixedPlate front connection
Back panel connection
Plug-in type Front connection
Rear connection
Outline dimensions (mm)Width (W)×Height (H)×Depth (D)3P 92×160×75.5
92×160×91
4P 122×160×75.5
122×160×91
Note1. The isolation function is not suitable for 4A/4D poles. type circuit breaker;
2. When wiring down the incoming line, the breaking capacity needs to be derated by 75%;
3. The applicable rated voltage range of the advanced controller is: 100VAC~415VAC;
4. The breaking capacity of the advanced controller is only Q type.

Parameter table 2

< td>
Parameter classificationParameter itemParameter value
System parameterCurrent range125-160- 180-200-225-250
250-315-350-400
Rated voltage1000
1000
Rated frequency8
12
Rated insulation voltage380/400/415
380/400/415
Wiring methodF Q R
F Q R
Rated short-time withstand current36 50 70
36 50 70 100
Rated peak withstand current36 50 50
50 70 70
StandardIEC/EN60947-2, GB/T14048.2
ModelA
Temperature range-25~+70
Inlet methodUp / Lower free entry
Zero flashover≤50/zero flashover (need to install short-circuit sub-cover TCV)
Performance indexRated limit short-circuit breaking capacity 20000
10000
Rated operating short-circuit breaking capacity4000 0
20000
Rated connection capacity10000
8000
Communication
Protection function
InstallationDimensions107×175×76.5
107×175×101.5
140×267×111
140×267×111
142×175×76.5
142×175×101.5
184×267×111
184×267×111

Parameter table 3

< td>
Parameter classificationParameter itemParameter value
Product modelNMSNELE-630
Rated operating current In,40°C400-500-630
Electrical performanceRated insulation voltage Ui(V)1000
Rated impulse withstand voltage Uimp(kV)12
Rated operating voltage Ue(V),AC50/60Hz380/400/415
Number of poles3P
4P (3P+N, 4P)
Breaking capacityF
Q
R
Rated limit short circuit breaking capacity Icu(kA)AC380/400/415V 50
70
100
Rated operating short-circuit breaking capacity Ics(kA)AC380/400/415V 50
70
70
Power-on indication
Leakage alarm does not work Trip
Comply with standardsIEC/EN60947-2.Z/GB/T14048 .2
Usage categoryA
Working environment temperature (°C)-25~+70
Isolation function
Wiring methodFree entry and exit of upper/lower wires
Arc distance≤50/zero arcing (need to install short terminals CV)
Mechanical life (times)Maintenance-free 10000
With maintenance 20000
Electrical life (times)AC400/415V 8000
Protection typeDistribution protection
Motor protection
Installation and connectionFixedFront plate connection ■
Back-board connection ■
Plug-in typeFront-board connection ■
Back-board connection ■
DimensionsWidth (W) × Height (H) × Depth (D) 3P 140×267×111 140×267×111
4P 184×267×111 184×267×111
Note1. The isolation function is not applicable to circuit breakers with 4A/4D poles; Use;
3. The applicable rated voltage range of the advanced controller is 100VAC-415VAC;
4. The breaking capacity of the advanced controller is only Q type.

Parameter table 4

Parameter classificationParameter itemParameter value
NMSNELE-800System parameters800:400-500-630-700-800
1000
12
380/400/415
F50
Q70
R100
50
70
70
10000
20 000
800:5000

Requirement confirmation

Application, rating, quantity and drawings are checked first.

Factory matching

Supplier capacity, certificates and production slot are reviewed.

Order transaction

Confirm commercial terms, sign the commercial contract, and confirm the related document checklist.

Shipment control

Packing photos, inspection records and delivery status are tracked.