| System Parameters | Rated insulation voltage Ue (V) | 800 |
| Rated impulse withstand voltage Uimp (kV) | 8 |
| Operating frequency (Hz) | AC 50/60Hz |
| Rated current In(A) | 125, 160, 250, 400, 630 |
| Rated short-time withstand current Icw (4s), 40℃ | 10.16, 20.25, 32.50, 40.50, 61.100, 100.125, 125.160, 180.200, 225.250, 250.280, 315.320, 350.350, 380.400, 400.400, 600.600 |
| Rated peak withstand current Ipk (kA) | 25, 32, 40, 50, 61, 100, 125, 160, 180, 200, 225, 250, 280, 315, 320, 350, 350, 380, 400, 400, 600, 600 |
| Rated short-circuit breaking current Icu (kA) | 40k/415, 40k/415, 40k/415, 40k/415, 40k/415 |
| Rated short-circuit making current Icm (kA) | 40k/415, 40k/415, 40k/415, 40k/415, 40k/415 |
| Rated operating sequence | A: 30.50.100.200, B: 90.100.200.300, C: 100.200.300.500, D: 100.200.300.500, E: 90.100.200.300 |
| Rated operating current Ie(A) | Adjustable, instantaneous type |
| Rated thermal stable current Ith (4s) | AC type, A Type: 30.50.100.200, B: 90.100.200.300, C: 100.200.300.500, D: 100.200.300.500, E: 90.100.200.300 |
| Rated dynamic stable current Idyn (kA) | Adjustable, time-delay type |
| Rated short-time withstand current Icw (2s) | ≤0.04, ≤0.04, ≤0.04, ≤0.04, ≤0.04 |
| Rated short-time withstand current Icw (2s) Maximum inactive time (T) | 0.1, 0.1/0.3, optional, 0.1/0.3, optional, 0.3/0.5, optional, 0.3/0.5, Optional, 0.3/0.5, optional |
| Rated 20mΩ maximum breaking time (t) | 0.3, 0.3, 0.3, 0.3, 0.3 |
| Performance index | Breaking capacity code | S, H, H, H, H |
| Number of poles | SP, SP+N, SP+P, SP+P, SP+P |
| Rated control and auxiliary circuit current Icc(A) | 25, 36, 35, 50, 35, 50, 70, 50, 70 |
| Rated control and auxiliary circuit connection capacity Icc(A) | 13, 18, 18, 25, 18, 25, 25, 36, 36 |
| Rated control and auxiliary circuit breaking capacity Icc(A) | 13, 18, 18, 25, 18, 25, 25, 36, 36 |
| Rated control and auxiliary circuit connection capacity Icc(A) | IEC/EN 60947-4-2, GB/T 14048.2, IEC/EN 60947-4-2, GB/T 14048.2 |
| Usage category | * , * , * , * , A |
| Rated functional current (applicable to type C products) | * , * , * , * , A |
| Applicable working environment temperature | -25℃~+70℃, -25℃~+70℃, -25℃~+70℃, -25℃~+70℃, -25℃~+70℃ |
| Arc distance | ≤50, ≤50, ≤50, ≤50, ≤100 |
| Mechanical life (times) | No maintenance: 20000, with maintenance: 40000, without maintenance: 10000, with maintenance: 20000, without maintenance: 20000, with maintenance: 40000, without maintenance: 10000, with maintenance: 20000, without maintenance: 8000, with maintenance: 16000 |
| Electrical life (times) | AC415V, % 10000, 10000, 10000, 10000, 10000 |
| Accessories | Auxiliary contacts (1 normally open, 1 normally closed) * , * , * , * , * |
| | Auxiliary contacts (P open 2 P closed 2) - , - , - , - , - |
| | Auxiliary contact (P open 2 P closed 2) - , - , - , - , - |
| | Auxiliary contact (P open 2 P closed 2) - , - , - , - , - |
| | Auxiliary contact (P open 2 P closed 2) - , - , - , - , - |
| | Auxiliary contact (P open 2 P closed 2) - , - , - , - , - |
| | Auxiliary contact (P open 2 P closed 2) - , - , - , - , - |
| | Auxiliary contact (P open 2 P closed 2) - , - , - , - , - |
| | Auxiliary contact (P open 2 P closed 2) - , - , - , - , - |
| | Auxiliary contact (P open 2 P closed 2) - , - , - , - , - |
| | Auxiliary contact (P open 2 P closed 2) - , - , - , - , - |
| | Auxiliary contact (P open 2 P closed 2) - , - , - , - , - |
| | Auxiliary contact (P open 2 P closed 2) - , - , - , - , - |
| | Auxiliary contact (P open 2 P closed 2) - , - , - , - , - |