NXMLE series residual current operated circuit breaker

Product category:
Residual Current Circuit Breaker (RCCB)
Product code:
P-287
Model:
NXMLE

Function & Use (Application Scenarios)

Distribution appliances and residual current action circuit breaker products are mainly suitable for the series of residual current action circuit breakers. Their main functions are to provide indirect contact protection against fatal personal electric shock and to provide protection against electrical fires caused by ground fault current, such as insulation damage, etc. And to the line

Surprise on inquiry

Product highlights

  • Reliable overload protection
  • Short circuit protection capability
  • Leakage protection support
  • Strong breaking ability
  • Easy to install and maintain

Model

NXMLE

Main Product Parameters

ClassificationswitchgearSecondary classificationResidual current operated circuit breaker
parametersOperating breaking capacity: Ics=25/36/50; ultimate breaking capacity: Icu=36/50/70Advantages/core features01 Comprehensive functions; can carry out leakage protection, overload long delay, short circuit short delay, short circuit instantaneous and other protection to meet various protection needs of customers; 02 Safe and reliable; double protection design of upper cover and middle cover allows customers to use it in various complex environments; 03 Compact and convenient; the product is smaller than competing products, easy to layout and saves installation space

Product details

Function and use

The main function of the residual current operated circuit breaker series is to provide indirect contact protection against fatal personal electric shock, and to provide protection against electrical fires caused by ground fault current, such as insulation damage, etc. It also provides protection against overload, short circuit and under-voltage of the line, and can also be used for infrequent switching of the line.

Detailed description

Parameters:
Operating breaking capacity: Ics=25/36/50
Ultimate breaking capacity: Icu=36/50/70

Advantages/core functions:
01 Comprehensive functions
Can carry out leakage protection, overload long delay, short circuit short delay, short circuit instantaneous and other protection to meet customers' various protection needs
02 Safe and reliable
Double protection design of upper cover and middle cover, customers can use it in various complex environments
03 Compact and convenient
The product is smaller than competing products, easy to layout, saving installation space

Detailed parameters

< td>40000 td>
Parameter classificationParameter itemsParameter value
Load level rated current Inm(A)12510,16,20,25,32,40,50,63,80,100,125
160(W125)160:25,32,40,50,63,80, 100,125,160
W125:25,32,40,50,63,80,100,125
< /td>250125,160,180,200,225,250
Rated current In(A), 40℃
Rated insulation voltage Ui(V)800
Rated impulse withstand voltage Uimp(kV)8
Rated operating voltage Ue(V), AC 50/60Hz230/240 (2P applicable), 400/415
Residual current typeAC Type, A type
Adjustable, non-delay type(2P, 3P+N, 4P) Single gear not adjustable, non-delay type
30/50/100/200/300/500
(2P, 3P+N, 4P) Single gear is not adjustable, delay type
50/100/200/300/500
Adjustable, delay typeA: 30.50.100.200
C: 100.200.300.500
B: 50.100.200.300
C: 100.200.300.500
Rated residual current value IΔn (mA)
Rated residual non-operating current IΔno(mA)0.5IΔn
Non-delay type 5IΔn Maximum breaking time (s)≤ 0.04
Delay type 21IΔn Limit non-driving time (s) is not adjustable0.1/0.2/0.3, optional
Delay type 21IΔn Maximum breaking time (s)0.3/0.4/0.5, Optional
Breaking capacity code1P+NS
2P-
3P
3P+N
4P
Rated limit short-circuit breaking capacity Icu(kA), (AC230V/240V)(1P+N, 2P)/(AC400V//415V)(3P,3P+N,4P)36/25
-/36
50/35
/-50
50/35
/-50
Rated operating short-circuit breaking capacity Ics(kA), (AC230V/240V)(1P+N, 2P)/(AC400V//415V)(3P,3P+N,4P)18/13
-/18
30/18
/-25
30/18
/-25
Comply with standardsIEC/EN 60947-2, GB/T 14048.2
Use categoryA
Isolation function (B, C Applicable to type products)
Applicable working environment temperature
Flashover distance (mm)≤ 50
Mechanical life (times)Maintenance-free20000
Maintenance required
Electrical life (times)10000
AccessoriesAuxiliary contacts (1 open 1 closed)
Auxiliary contacts (2 open 2 Closed)-
Alarm contact
Auxiliary contact Alarm contact
Shunt release
Undervoltage release
Residual current alarm non-tripping module-
Manual operating mechanism
Electric operating mechanism
Rear panel wiring
Plug-in type
Extended terminal connection row
Phase barrier
Outline dimensions (mm) Width (W) × Height (H) × Depth (D)Narrow (1P+N/2P/3P/3P+N/4P)/-/78/103/103
63/63/90/120/120
78/78/105/140/140
High156
Deep (S Type/H type)71/81
75.5/91
77/80

Requirement confirmation

Application, rating, quantity and drawings are checked first.

Factory matching

Supplier capacity, certificates and production slot are reviewed.

Order transaction

Confirm commercial terms, sign the commercial contract, and confirm the related document checklist.

Shipment control

Packing photos, inspection records and delivery status are tracked.