NM2LC residual current protection circuit breaker

Product category:
Residual Current Circuit Breaker (RCCB)
Product code:
P-289
Model:
NM2LC

Function & Use (Application Scenarios)

Distribution appliances and residual current action circuit breaker products are mainly suitable for NM2LC series residual current protection circuit breakers. They are suitable for three-phase four-wire neutral point directly grounded (TT) distribution grids with AC 50Hz, rated voltage 400V, and rated current up to 800A, and are used to protect people from electric shock.

Surprise on inquiry

Product highlights

  • Short circuit protection capability
  • Leakage protection support
  • Engineering application adaptation
  • Stable and reliable operation
  • Easy system integration

Model

NM2LC

Main Product Parameters

ClassificationswitchgearSecondary classificationResidual current operated circuit breaker

Product details

Function and purpose

NM2LC series residual current protection circuit breaker is suitable for AC 50Hz, rated voltage 400V, rated current up to 800A three-phase four-wire neutral point directly grounded (TT) distribution network. It is used to provide indirect contact protection against personal electric shock hazards, and can also protect lines or electrical equipment from overcurrent, short circuit, undervoltage, overvoltage, phase loss and power supply side zero interruption.

Detailed parameters

Parameter table 1

< td>0.5IΔn
Parameter classificationParameter itemParameter value
Product seriesSpecification modelNM2LC-125, NM2LC-250, NM2LC-400, NM2LC-630, NM2LC-W630, NM2LC-800
Frame current Inm(A)125, 250, 400, 630, 630, 800
Number of poles3P+N (N line is on the right side of the product)
Rated current In(A)50-63-80-100-125, adjustable; 100-125-140-160-180-200-225-250, adjustable; 200-225-250-315-350-400, adjustable; 315-350-400-500-630, adjustable; 250-315-350-400-450-500-560-630, adjustable; 315-350-400-450-500-560-630--700-800, adjustable
Rated insulation voltage Ui (V)1000
Rated impulse withstand voltage Uimp(kV)8
Rated operating voltage Ue(V)AC400, 50Hz
Release typeElectronic (three-stage protection, electronically adjustable)
Use categoryA, A, B, B, B, B
Breaking capacity codeH, M, H, M, H, M, M
Rated ultimate short-circuit breaking capacity Icu (kA)70, 50, 70, 50, 85, 65, 65, 65, 35
Rated operating short-circuit breaking capacity Ics (kA)50, 35, 50, 35, 65, 42, 65, 42, 50, 35
Rated short-time withstand current Icw, 1s (kA)1.5, 3, 5, 8, 8, 10
Residual current operating characteristicsAC
Rated residual operating current IΔn (mA)Conventional products: 30/50/100/200/300/400/500/600/800/1000, adjustable, 30mA is non-delay, without reclosing function; new protocol products: 30/50/100/200/300/400/500/600/800/1000, adjustable, 30mA is non-delay, without reclosing function
Rated residual current non-action value IΔno (mA)
Residual current action time typeDelay type/non-delay type
Breaking time (s)Delay type: ≤0.5(IΔn); ≤0.2(2IΔn); ≤0.15(5IΔn, 10IΔn); Non-delay type: ≤0.3(IΔn); ≤0.15(2IΔn); ≤0.04(5IΔn, 10IΔn)
Delay type limit non-driving time (s)2IΔn: 0.06/2IΔn: 0.06, 0.1, 0.2 (new protocol product)
Automatic reclosing time (s)20-60
Overvoltage protection value (V)Setting value (240~300)±5% (conventional products)/(245~300)±2% ( New protocol products)
Undervoltage protection value (V)Setting value (145~200)±5% (conventional products )/(140~200)±2% (new protocol product)
Operating performance (times)Power on1500, 1000, 1000, 1000, 1000, 500
Not powered8500, 7000, 4000, 4000, 4000, 2500
Total times10000, 8000, 5000, 5000, 5000, 3000
Outline and installation dimensionsWidth (W)122, 142, 198, 198, 240, 280
High (H)150, 165, 257, 336, 350, 370
Deep (D)124, 136, 180, 180, 183.5, 186

Parameter table 2

< /tr>< tr>B< tr> td>< /tr>< /tr>4000
Parameter classificationParameter itemParameter value
Product seriesSpecification model NM2LC-125Z
NM2LC-250Z
NM2LC -400Z
NM2LC-630Z
Frame current Inm(A)125
250
400
630
Number of poles3P+N (N line is on the left side of the product)
Rated current In(A)50-63 -80-100-125, adjustable
100-125-140-160-180-200-225-250, adjustable
200-225-250-315-350-400, adjustable
315-350-400-500-630, adjustable
Rated insulation voltage Uli(V)1000
Rated impulse withstand voltage Uimp(kV)8
Rated operating voltage Ue (V)AC400, 50Hz
Tripping device typeElectronic (three-stage protection, electronically adjustable)
Use categoriesA
A
B
Rated ultimate short-circuit breaking capacity Icu(kA)18
18
25
35
Rated operating short-circuit breaking capacity Ics (kA)18
18
25
35
Rated short-time withstand current Icw, 1s (kA)1.5
3
5
8
Residual current operating characteristicsAC
Rated residual operating current IΔn (mA) Conventional products: 30/50/100/200/300/400/500/600/800/1000, adjustable
30mA is non-delay, without reclosing function
New protocol products:
Rated residual current inaction value IΔno (mA)0.5IΔn
Residual current action time typeDelay type/non-delay type
Breaking time (s)Delay type: ≤0.5 (IΔn); ≤0.2 (2IΔn); ≤0.15 (5IΔn, 10IΔn)
Non-delay type: ≤0.3(IΔn); ≤0.15(2IΔn); ≤0.04(5IΔn, 10IΔn)
Delay type limit is not driven Automatic reclosing time (s)2IΔn:0.06/2IΔn:0.06, 0.1, 0.2 (new protocol product)
Automatic reclosing time (s)20-60
Overvoltage protection value (V)Set value (240~300)±5% (conventional products)/(245~300)±2% (new protocol products)
Ow Voltage protection value (V)Set value (145~200)±5% (conventional products)/(140~200)±2% (new protocol products)
Operation performance (times)Power on: 150 0
No power: 8500
Total times: 10000
Width (W): 122
Height (H): 220
Depth (D):120
1000
7000
8000
142
240
138
1000
5000
198
336
180
1000
4000
5000
198
336
180

Requirement confirmation

Application, rating, quantity and drawings are checked first.

Factory matching

Supplier capacity, certificates and production slot are reviewed.

Order transaction

Confirm commercial terms, sign the commercial contract, and confirm the related document checklist.

Shipment control

Packing photos, inspection records and delivery status are tracked.