Terminal electrical appliances and small circuit breaker products are mainly suitable for lines with AC 50Hz rated voltage 230/400V and rated current up to 63A. They serve as overload and short-circuit protection. They can be used for infrequent switching of lines under normal circumstances, and can also be used for disconnection.

Surprise on inquiry

Product highlights

  • Reliable overload protection
  • Short circuit protection capability
  • Reliable isolation and protection
  • Engineering application adaptation
  • Stable and reliable operation

Model

NB1-63

Main Product Parameters

ClassificationswitchgearSecondary classificationminiature circuit breaker

Product details

Function and use

NB1-63 □ small circuit breaker is suitable for lines with AC 50Hz rated voltage 230/400V and rated current up to 63A. It serves as overload and short-circuit protection. It can be used for infrequent switching of lines under normal circumstances, and can also be used as an isolating switch for disconnecting lines for line and equipment maintenance. Circuit breakers are suitable for various places such as industrial, commercial, high-rise and residential buildings. Comply with standards: GB/T 10963.1, IEC 60898-1, and obtain CCC, CE, SEMKO and other certifications.

Detailed parameters

IP20
Parameter classificationParameter itemsParameter value
Technical parametersRated voltage (Ue)AC 230V/400V(IP), AC 400V(2P, 3P, 4P)
Rated current (In)1A, 2A, 3A, 4A, 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A
Rated insulation voltage (Ui)500V
Rated impulse withstand voltage (Uimp)4kV
Number of poles1P, 2P, 3P, 4P
New tripping typesType B, Type C, Type D
Room buckle characteristicsSee Figure 4, Figure 2, Figure 3
Temperature compensation coefficientSee Table 7
Different Positive coefficient of ambient temperatureSee Table 8
Mechanical and electrical lifespanSee Table 3
Rated short-circuit breaking capacity (icn)See Table 2
Rated limit short-circuit current ( Icu)3
Connecting wiresSee Table 5
Operating torque2.0N·m
Outline and installation dimensionsSee Figure 4
Pollution levelLevel 2
Protection level
Installation CategoryII, III Category
Main Technical Parameters NumberRated short circuit breaking capacity (icn)
Model numberNB1-63, NB1-63H
Rated current (A)1-63, 1-63
Number of poles1, 1
Rated voltage (V)230/400, 230/400
Rated short-circuit current (A)6000, 10000
Operating short-circuit current (A)6000, 7500
Mechanical and electrical lifeCategory
Number of times (times)10000, 200000
Operating frequency (times/hour)240, 240
Rated current (A)1-32, 1-63
Expected resultsNo tripping, Trip
RemarksThe current rises steadily to the specified value within 5s
Overcurrent protection characteristics (reference temperature 30℃)Serial numbera, b, c, d
ModelB, C, D, B, C, D
Rated current of tripper (A)1-63, 1-63, 1-63, 1-63
Initial stateCold state, cold state, cold state, cold state
Test current1.13In, 1.45In, 2.55In, 3In, 5In, 10In, 14In
Specified timet≤1h, t≤1h, 1s<60s, 1s<120s, t≤0.1s, t≤0.1s, t≤0.1s
Expected resultsNo tripping, tripping, tripping, tripping, no tripping, no tripping, no tripping
Tripping characteristic curveFigure 1 Type B
Figure 2 Type C
Figure 3 Type D

Requirement confirmation

Application, rating, quantity and drawings are checked first.

Factory matching

Supplier capacity, certificates and production slot are reviewed.

Order transaction

Confirm commercial terms, sign the commercial contract, and confirm the related document checklist.

Shipment control

Packing photos, inspection records and delivery status are tracked.