DZ47-60 Miniature Circuit Breaker

Product category:
Miniature circuit breaker (air switch)
Product code:
P-300
Model:
DZ47-60

Function & Use (Application Scenarios)

Final electrical appliances, miniature circuit breakers are mainly used in AC 50Hz, rated voltage up to 400V, rated current up to 63A circuits to provide overload and short-circuit protection, and can also be used to switch on and off electrical devices and lighting circuits under normal conditions without frequent operations.

Surprise on inquiry

Product highlights

  • Overload protection is reliable
  • Short-circuit protection capability
  • Engineering Application Compatibility
  • Stable and reliable operation
  • Easy system integration

Model

DZ47-60

Main Product Parameters

CategorySwitchgearSecondary CategoryMiniature Circuit Breaker

Product details

Function and Usage

The DZ47-60 miniature circuit breaker is mainly used in AC 50Hz circuits with a rated voltage up to 400V and a rated current up to 63A for overload and short-circuit protection. It can also be used to frequently switch electrical devices and lighting circuits under normal conditions, but it is not suitable for motor protection. It complies with the standards GB/T 10963.1 and IEC 60898-1, and has obtained the CCC certification.

Detailed Parameters

Parameter CategoryParameter ItemParameter Value
System ParametersRated Voltage (AC)AC230V/400V(P), AC400V(2P, 3P, 4P)
Rated Current1A, 2A, 3A, 4A, 5A, 6A, 10A, 15A, 20A, 25A, 32A, 40A, 50A, 63A
Rated Insulation Voltage (Ui)500V
Rated Impulse Withstand Voltage (Uimp)4kV
Poles1P, 2P, 3P, 4P
Tripping Curve TypeC Type, D Type
Delay CharacteristicsSee Table 3
Performance IndicatorsCorrection Factor at Different Ambient TemperaturesSee Table 4
Isolation ClearanceSee Table 5
Minimum Creepage DistanceSee Table 5
Vibration Torque2.0N·m
Dimensions and Installation DimensionsSee Figure 3, Figure 4
Pollution LevelLevel 2
Installation CategoryI Class
Overload CapabilityIP20
Protection LevelIP20
CommunicationNo
Protection FunctionNo
InstallationNo
OtherOperating Environmental Temperature-5℃~+40℃, average operating temperature within 24h does not exceed +35℃
Wiring MethodUse wires with cross-sectional area of *16mm² or less (see Table 7). The wiring method uses screw pressure connection with a torque of 2.0N·m
Conductor Cross-sectional Area (mm²)1, 1.5, 2.5, 4, 6, 10, 16, 25, 35, 50, 70, 95, 120, 150, 185, 240, 300, 400

Requirement confirmation

Application, rating, quantity and drawings are checked first.

Factory matching

Supplier capacity, certificates and production slot are reviewed.

Order transaction

Confirm commercial terms, sign the commercial contract, and confirm the related document checklist.

Shipment control

Packing photos, inspection records and delivery status are tracked.