NB8-63H Miniature Circuit Breaker

Product category:
Miniature circuit breaker (air switch)
Product code:
P-315
Model:
NB8-63H

Function & Use (Application Scenarios)

Terminal electrical appliances, miniature circuit breakers are mainly suitable for AC 50Hz, rated voltage up to 63A commercial office buildings, residential buildings, and general industrial applications of the terminal distribution lines, providing overload and short-circuit protection for the lines, and can also be used to switch the lines under normal conditions.

Surprise on inquiry

Product highlights

  • Overload protection is reliable
  • Short-circuit protection capability
  • Engineering Application Compatibility
  • Stable and reliable operation
  • Easy system integration

Model

NB8-63H

Main Product Parameters

CategorySwitchgearSecondary CategoryMiniature Circuit Breaker

Product details

Function and Use

The NB8-63H Miniature Circuit Breaker is mainly applicable to the terminal distribution lines of commercial office buildings, residential buildings, and general industrial applications with AC 50Hz, rated voltage up to 63A, providing overload and short circuit protection for the lines, and can also perform non-frequent switching operations under normal conditions.

Detailed Parameters

Parameter CategoryParameter ItemParameter Value
Product ModelNB8-63H
Rated Current (A)1、2、3、4、6、10、16、20、25、32、40、50、63
Rated Voltage (V)230/400
Rated Frequency (Hz)50
Poles1P、1P+N、2P、3P、3P+N、4P
Mechanical Life (times)20000
Electrical Life (times)10000
Rated Short-Circuit Breaking Capacity (A)10000
Operational Short-Circuit Breaking Capacity (A)7500
Rated Insulation Voltage (V)500
Rated Impulse Withstand Voltage (1.2/50) (kV)6
Dielectric Test Voltage (V)(50Hz, 1 minute) 2000
Resistance to Humidity and Heat (GB/T2423.4: 55℃/90~96%, 25℃/95~100%)28 Cycles
Resistance to Vibration (IEC/EN60068-2-6)Places without significant vibration and impact
Wiring TerminalTerminal FormPost-Type Terminal
Minimum Wire Cross Section Area (mm²)1
Maximum Wire Cross Section Area (mm²)25
Standard Connection Torque (N·m)2
Maximum Allowable Torque (N·m)2.5
Wire Insertion Depth (mm)13
Reference Temperature (℃)30
Operating Environmental Temperature (℃)-35~+70
Storage Environmental Temperature (℃)-35~+85
Applicable Altitude (m)2000
Tripping TypeThermal-Magnetic Tripping
Electromagnetic Tripping TypeB Type (3In~5In)
C Type (5In~10In)
D Type (10In~16In)
Enclosure Flame Retardant RatingV0
Input MethodTop and Bottom Both Possible
Installation MethodTH35-7.5 Standard Rail
Pollution Level3
Protection LevelDirect InstallationIP20B
Installed in Distribution BoxIP40B
Removable AccessoriesS9、V9、XF9、XF9J、OVT-1、OUVT-1

Requirement confirmation

Application, rating, quantity and drawings are checked first.

Factory matching

Supplier capacity, certificates and production slot are reviewed.

Order transaction

Confirm commercial terms, sign the commercial contract, and confirm the related document checklist.

Shipment control

Packing photos, inspection records and delivery status are tracked.