NB8-40J Miniature Circuit Breaker

Product category:
Miniature circuit breaker (air switch)
Product code:
P-320
Model:
NB8-40J

Function & Use (Application Scenarios)

Terminal electrical appliances, small circuit breakers are mainly suitable for terminal distribution lines in commercial office buildings, residential buildings, and general industrial applications with AC 40A, providing overload and short-circuit protection for the lines, and can also perform infrequent switching operations under normal conditions

Surprise on inquiry

Product highlights

  • Reliable overload protection
  • Short-circuit protection capability
  • Engineering Application Compatibility
  • Stable and reliable operation
  • Easy system integration

Model

NB8-40J

Main Product Parameters

CategorySwitchgearSecondary CategoryMiniature Circuit Breaker

Product details

Function and Usage

The NB8-40J miniature circuit breaker is mainly applicable to the terminal power distribution lines of commercial office buildings, residential buildings, and general industrial applications with AC 40A, providing overload and short-circuit protection for the lines, and can also perform non-frequent switching operations under normal conditions.

Detailed Parameters

Parameter CategoryParameter ItemParameter Value
Product ModelNB8-40J
Rated Current (A)1, 2, 3, 4, 6, 10, 16, 20, 25, 32, 40
Rated Voltage (V)230/400
Rated Frequency (Hz)50
Pole Number1P, 2P, 3P, 4P
Mechanical Life (Times)15000
Electrical Life (Times)10000
Rated Short-Circuit Breaking Capacity (A)4500 (D), 6000 (B, C)
Operational Short-Circuit Breaking Capacity (A)4500 (D), 6000 (B, C)
Rated Insulation Voltage (V)500
Rated Impulse Withstand Voltage (1.2/50) (kV)4
Dielectric Test Voltage (V)(50Hz, 1 minute) 2000
Humidity and Heat Resistance (GB/T2423.4: 55℃/90~96%, 25℃/95~100%)28 Cycles
Vibration Resistance (IEC/EN60068-2-6)Places without obvious vibration and impact
TerminalsTerminal TypePost-Type Terminals
Minimum Wire Cross-sectional Area (mm²)1
Maximum Wire Cross-sectional Area (mm²)16
Standard Connection Torque (N·m)2
Maximum Allowable Torque (N·m)2.5
Wire Insertion Depth (mm)10
Reference Temperature (℃)30
Operating Ambient Temperature (℃)-35~+70
Storage Ambient Temperature (℃)-35~+85
Applicable Altitude (m)2000
Tripping MechanismThermal-Magnetic Tripping
Electromagnetic Tripping TypeB Type (3In~5In)
C Type (5In~10In)
D Type (10In~16In)
Enclosure Flammability RatingV0
Wiring MethodTop or Bottom
Installation MethodTH35-7.5 Standard Rail
Pollution Level2
Protection LevelDirect InstallationIP20B
Installed in Distribution BoxIP40B
Removable AccessoriesS9, V9, XF9, XF9J, OVT-1, OUVT-1

Requirement confirmation

Application, rating, quantity and drawings are checked first.

Factory matching

Supplier capacity, certificates and production slot are reviewed.

Order transaction

Confirm commercial terms, sign the commercial contract, and confirm the related document checklist.

Shipment control

Packing photos, inspection records and delivery status are tracked.