NB8-63 Mini Circuit Breaker

Product category:
Miniature circuit breaker (air switch)
Product code:
P-321
Model:
NB8-63

Function & Use (Application Scenarios)

Final electrical devices, small circuit breakers are mainly suitable for the terminal distribution lines of commercial office buildings, residential buildings, and general industrial applications with AC 63A, providing overload and short-circuit protection for the lines, and can also perform infrequent switching operations under normal conditions

Surprise on inquiry

Product highlights

  • Overload protection reliable
  • Short-circuit protection capability
  • Engineering Application Compatibility
  • Stable and reliable operation
  • Easy system integration

Model

NB8-63

Main Product Parameters

CategorySwitchgearSecondary CategoryMiniature Circuit Breaker

Product details

Function and Usage

The NB8-63 miniature circuit breaker is mainly applicable to the terminal power distribution lines of commercial office buildings, residential buildings, and general industrial applications with AC 63A, providing overload and short-circuit protection for the lines, and can also perform non-frequent switching operations under normal conditions.

Detailed Parameters

Parameter CategoryParameter ItemParameter Value
Product ModelNB8-63
Rated Current (A)1, 2, 3, 4, 6, 10, 16, 20, 25, 32, 40, 50, 63
Rated Voltage (V)230/400
Rated Frequency (Hz)50
Poles1P, 1P+N, 2P, 3P, 3P+N, 4P
Mechanical Life (Times)20000
Electrical Life (Times)10000
Rated Short-Circuit Breaking Capacity (A)6000
Running Short-Circuit Breaking Capacity (A)6000
Rated Insulation Voltage (V)500
Rated Impulse Withstand Voltage (1.2/50) kV6
Dielectric Test Voltage (V)(50Hz, 1 minute) 2000
Resistance to Humidity and Heat (GB/T2423.4: 55℃/90~96%, 25℃/95~100%)28 Cycles Cycle
Vibration Resistance (IEC/EN60068-2-6)Places without obvious vibration and impact
Wiring TerminalTerminal TypeColumn Wiring Terminal
Minimum Wire Cross-sectional Area (mm²)1
Maximum Wire Cross-sectional Area (mm²)25
Standard Connection Torque (N·m)2
Maximum Allowable Torque (N·m)2.5
Wire Insertion Depth (mm)13
Reference Temperature (℃)30
Operating Environmental Temperature (℃)-35~+70
Storage Environmental Temperature (℃)-35~+85
Applicable Altitude (m)2000
Tripping TypeThermal-magnetic Tripping
Electromagnetic Tripping TypeB Type (3In~5In)
C Type (5In~10In)
D Type (10In~16In)
Enclosure Flammability RatingV0
Wiring MethodTop and Bottom Both Possible
Installation MethodTH35-7.5 Standard Rail
Pollution Level3
Protection LevelDirect Installation IP20B
Installation Inside Distribution Box IP40B
Modular AccessoriesS9, V9, XF9, XF9J, OVT-1, OUVT-1

Requirement confirmation

Application, rating, quantity and drawings are checked first.

Factory matching

Supplier capacity, certificates and production slot are reviewed.

Order transaction

Confirm commercial terms, sign the commercial contract, and confirm the related document checklist.

Shipment control

Packing photos, inspection records and delivery status are tracked.