NXBL□-63□YH□ Residual Current Operated Circuit Breaker

Product category:
Residual Current Circuit Breaker (RCCB)
Product code:
P-328
Model:

Function & Use (Application Scenarios)

End devices, residual current operated circuit breakers are mainly applicable to NXBLE-63YH, NXBLG-63YH residual current operated circuit breakers complying with GB/T16917.1 standard. Applicable for AC 50Hz, rated voltage 230V or 400V, rated

Surprise on inquiry

Product highlights

  • Reliable overload protection
  • Short-circuit protection capability
  • Leakage protection support
  • Engineering Application Compatibility
  • Stable and reliable operation

Model

Main Product Parameters

CategorySwitchgearSecondary CategoryResidual current operated circuit breaker

Product details

Function and Use

NXBLE-63YH and NXBLG-63YH residual current circuit breakers comply with GB/T16917.1 standard. They are suitable for AC 50Hz, rated voltage 230V or 400V, and rated current up to 63A circuits, providing overload, short-circuit, and residual current protection. They can also be used as infrequent switching in normal conditions. NXBLE-63GYH residual current circuit breakers comply with GB/T14048.2 standard. They are suitable for AC 50/60Hz, rated voltage 230V or 400V, and rated current up to 63A circuits, providing overload, short-circuit, and residual current protection. They can also be used as infrequent switching in normal conditions.

Detail Parameters

Parameter Table 1

Parameter CategoryParameter ItemParameter Value
Product ModelNXBL □-63YH □
Rated Current (A)6, 10, 16, 20, 25, 32, 40, 50, 63
Rated Residual Operating Current (mA)AC Type:10(1P+N, 2P): 30, 50, 75, 100, 300
A Type:30, 100, 300
Overvoltage Setting Value(280±14)V (NXBLG-63YH 1P+N, 2P)
Leakage Protection TypeA Type (NXBLE-63YH), AC Type
Rated Voltage (V)1P+N, 2P: AC230V
3P, 3P+N, 4P: AC400V
Rated Frequency (Hz)50
Pole Number1P+N (with one protective pole, N pole cannot be opened and closed), 2P (with one protective pole, N pole can be opened and closed), 3P, 3P+N, 4P
Mechanical Life (times)20000
Electrical Life (times)10000
Rated Short Circuit Breaking Capacity (A)6000
Operating Short Circuit Breaking Capacity (A)6000
Rated Insulation Voltage (V)500
Rated Impulse Withstand Voltage (1.2/50) (kV)4
Dielectric Test Voltage (V)(50Hz, 1 minute) 2000
Humidity and Heat Resistance (GB/T2434.4-55℃/90~96%, 25℃/95~100%)28 Cycles of Circulation
Vibration Resistance (IEC/EN60068-2-6)Places without significant vibration and impact
Wiring TerminalWiring Terminal TypeThreaded type for external copper conductors
Minimum Conductor Cross-sectional Area (mm²)1
Maximum Conductor Cross-sectional Area (mm²)25
Standard Connection Torque (N.m)2
Maximum Allowable Torque (N.m)2.5
Conductor Insertion Depth (mm)10
Reference Temperature (°C)30
Operating Ambient Temperature (°C)-35~+70
Storage Ambient Temperature (°C)-35~+85
Applicable Altitude (m)2000
Tripping FormThermal Magnetic Tripping
Electromagnetic Tripping TypeC Type (5In~10In)
D Type (10In~16In)
Derating Factor for Multiple Products Installed Side by Side (Recommended Value)¹⁾≤3 Units(0.9~0.95)In
4~6 Units(0.8~0.86)In
7~9 Units(0.76~0.78)In
>9 Units0.76In
≤2000mIn
Rated Current Correction Factor for High Altitude Use (Recommended Value)¹⁾3000m0.96In
4000m0.94In
5000m0.92In
Input MethodTop Input Bottom Output (NXBL □-63YH), Bottom Input Top Output (NXBL □-63YHF, only 1P+N and 2P)
Installation MethodTH35-7.5 Standard Rail
Pollution Level2
Protection LevelIP20
Modular AccessoriesAX-X1, AL-X1, SHT-X1, UVT-X1, OVT-X1 (excluding NXBLG-63YH), OUVT-X1 (excluding NXBLG-63YH)

Parameter Table 2

Parameter CategoryParameter ItemParameter Value
Product ModelNXBLE-63GYH
Rated Current (A)6, 10, 16, 20, 25, 32, 40, 50, 63
Rated Residual Operating Current (mA)AC Type:10, 30, 50, 100, 300
A Type:30, 50, 100, 300
Leakage Protection TypeA Type, AC Type
Rated Voltage (V)2P:AC230V
3P, 4P:AC400V
Rated Frequency (Hz)50/60
Pole Number2P (with one protective pole, N pole can be opened and closed), 3P, 4P
Mechanical Life (times)20000
Electrical Life (times)10000
Rated Short Circuit Breaking Capacity (A)6000
Operating Short Circuit Breaking Capacity (A)6000
Rated Insulation Voltage (V)500
Rated Impulse Withstand Voltage (1.2/50) (kV)4
Dielectric test voltage (V)(50Hz, 1 minute)2000
Resistance to humidity and heat (GB/T2434.4: 55℃/90~96%, 25℃/95~100%)28 cycles of circulation
Shock resistance (IEC/EN60068-2-6)Place without obvious vibration and impact
TerminalsTerminal typeThreaded type for external copper wire
Minimum wire cross-sectional area (mm²)1
Maximum wire cross-sectional area (mm²)25
Standard connection torque (N.m)2
Maximum allowable torque (N.m)2.5
Wire insertion depth (mm)10
Reference temperature (℃)30
Operating ambient temperature (℃)-35--+70
Storage ambient temperature (℃)-35--+85
Applicable altitude (m)2000
Tripping typeThermal-magnetic tripping
Electromagnetic tripping typeC type (6.4ln~9.6ln)
D type (9.6ln~14.4ln)
Derating factor for multiple products installed side by side (recommended value)¹≤3 units(0.9~0.95)ln
4~6 units(0.8~0.86)ln
7~9 units(0.76~0.78)ln
>9 units0.76ln
Rated current correction factor for high altitude usage (recommended value)¹≤2000mIn
3000m0.96ln
4000m0.94ln
5000m0.92ln
Wiring methodTop in bottom out
Installation methodTH35-7.5 standard rail
Pollution degree3
Protection classIP20
Compatible accessoriesAX-X1, AL-X1, SHT-X1, UVT-X1, OVT-X1, OUVT-X1
Note 1:Recommended values under the product's application scenarios, for reference only. The specific correction values should be comprehensively evaluated according to the user's actual working conditions.

Requirement confirmation

Application, rating, quantity and drawings are checked first.

Factory matching

Supplier capacity, certificates and production slot are reviewed.

Order transaction

Confirm commercial terms, sign the commercial contract, and confirm the related document checklist.

Shipment control

Packing photos, inspection records and delivery status are tracked.