NB3LE-63M Residual Current Operated Circuit Breaker

Product category:
Residual Current Circuit Breaker (RCCB)
Product code:
P-335
Model:
NB3LE-63M

Function & Use (Application Scenarios)

Final electrical devices, residual current operated circuit breakers are mainly applicable to this product which is suitable for AC 50Hz, rated voltage 230V, rated current up to 63A circuits, to provide overload, short circuit and leakage protection, and can also be used as infrequent switching in normal conditions. Conforms to

Surprise on inquiry

Product highlights

  • Overload protection is reliable
  • Short-circuit protection capability
  • Leakage protection support
  • Engineering Application Compatibility
  • Stable and reliable operation

Model

NB3LE-63M

Main Product Parameters

CategorySwitchgearSecondary CategoryResidual Current Operated Circuit Breaker

Product details

Function and Application

This product is suitable for AC circuits with a frequency of 50Hz, rated voltage of 230V, and rated current up to 63A, providing overload, short circuit, and leakage protection. It can also be used for infrequent on-off operations in normal conditions. Complies with standards: GB/T 16917.1, IEC 61009-1, and has obtained CCC certification.

Detailed Parameters

Parameter CategoryParameter ItemParameter Value
System ParametersRated Voltage (AC)AC 220V
Rated Frequency50Hz
Rated Current (A)Single-pole: 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A
Double-pole: 25A, 32A, 40A, 50A, 63A
Rated Insulation Voltage (Ue)690V
Rated Impulse Withstand Voltage (Uimp)4kV
Rated Residual Operating Current (IΔn)General Type: 0.01A, 0.03A, 0.05A, 0.075A, 0.1A, 0.3A
Selective Type: 0.05A, 0.075A, 0.1A, 0.3A
Rated Residual Non-operating Current (IΔno)0.5IΔn
Residual Current Operation TypeAC Type
Terminal Type for Wiring2P
Rated Short Circuit Breaking Capacity (Icn)100kA
Rated Ultimate Short Circuit Breaking Capacity (Icu)65kA
Rated Service Short Circuit Breaking Capacity (Ics)Not less than 60% of the rated ultimate short circuit breaking capacity
Rated Limiting Short Circuit Current (Icm)Not less than 80% of the rated ultimate short circuit breaking capacity
Overcurrent Protection CharacteristicsCret 4
Wiring MethodCross 5
Shunt Trip and Alarm Contact SizeSee Figure 2, Figure 3
Undervoltage Trip2-pole
Circuit Breaker ClassIP20
Installation CategoryClass II
Performance Index
Communication
Protection Function
Installation

Requirement confirmation

Application, rating, quantity and drawings are checked first.

Factory matching

Supplier capacity, certificates and production slot are reviewed.

Order transaction

Confirm commercial terms, sign the commercial contract, and confirm the related document checklist.

Shipment control

Packing photos, inspection records and delivery status are tracked.