NXBLE-32 Residual Current Operated Circuit Breaker

Product category:
Residual Current Circuit Breaker (RCCB)
Product code:
P-346
Model:

Function & Use (Application Scenarios)

End devices, residual current operated circuit breakers are mainly applicable to 1 conforming to the standards GB/T16917.1, IEC61009-1, suitable for engineering matching, installation and maintenance, and long-term stable operation, meeting the requirements of on-site electrical system applications.

Surprise on inquiry

Product highlights

  • Leakage current protection support
  • Engineering Application Compatibility
  • Stable and reliable operation
  • Easy system integration

Model

Main Product Parameters

CategorySwitchgearSecondary categoryResidual Current Operated Circuit Breaker

Product details

Function and Usage

1. Complies with standard GB/T 16917.1, IEC 61009-1

Detailed Parameters

Parameter CategoryParameter ItemParameter Value
System ParametersRated Current (In)6A, 10A, 16A, 20A, 25A, 32A.
Rated Residual Operating Current (IΔn)0.01A (1P+N, 2P), 0.03A, 0.05A, 0.075A, 0.1A, 0.3A.
Rated Operating Voltage (Ue)230V~ (1P+N, 2P), 400V~ (3P, 3P+N, 4P).
Rated Insulation Voltage (Ui)500V.
Frequency50Hz.
Instantaneous Trip CharacteristicsB, C, D.
Overvoltage Protection Range ValueSee Table 1.
Number of Poles1.
Mechanical Life20000 times.
Electrical Life10000 times.
Breaking CapacitySee Table 1.
Rated Impulse Withstand Voltage (Uimp)4kV.
Rated Residual Connection and Disconnection Capacity (IΔm)630A.
Performance IndicatorsProduct ModelNXBLE-32
Number of Poles1P+N, 2P, 3P, 3P+N, 4P
Breaking Capacity (A)Icn: 6000, Ics: 6000
Overvoltage Action Range-
Product ModelNXBLG-32
Number of Poles1P+N, 2P
Breaking Capacity (A)Icn: 6000, Ics: 6000
Overvoltage Action Range(280±14)V
Product ModelNXBLE-32H
Number of Poles2P
Breaking Capacity (A)Icn: 10000, Ics: 7500
Overvoltage Action Range-
CommunicationProduct ModelNXBLE-32
Derating Factor for Parallel Installation of Multiple Units (Recommended Value)≤3 units: (0.9-0.95)In, 4-6 units: (0.80-0.86)In, 7-9 units: (0.76-0.78)In, >9 units: 0.76In
Altitude Correction Factor for Rated Current (Recommended Value)≤2000m: In, 3000m: 0.96In, 4000m: 0.94In, 5000m: 0.92In

Requirement confirmation

Application, rating, quantity and drawings are checked first.

Factory matching

Supplier capacity, certificates and production slot are reviewed.

Order transaction

Confirm commercial terms, sign the commercial contract, and confirm the related document checklist.

Shipment control

Packing photos, inspection records and delivery status are tracked.