NB1L-63 Residual Current Operated Circuit Breaker

Product category:
Residual Current Circuit Breaker (RCCB)
Product code:
P-354
Model:
NB1L-63

Function & Use (Application Scenarios)

Final electrical appliances, residual current operated circuit breakers are mainly applicable to AC 50Hz, rated voltage single-pole two-wire, two-pole 230V, three-pole, three-pole four-wire, four-pole 400V, rated current up to 63A circuits, when a person is electrocuted or the leakage current of the power grid exceeds the specified value

Surprise on inquiry

Product highlights

  • Overload protection is reliable
  • Leakage current protection support
  • Engineering Application Compatibility
  • Stable and reliable operation
  • Easy system integration

Model

NB1L-63

Main Product Parameters

CategorySwitchgearSecondary categoryResidual Current Operated Circuit Breaker

Product details

Function and Usage

The NB1L-63 residual current circuit breaker is suitable for AC 50Hz, rated voltage single-pole two-wire, two-pole 230V, three-pole, three-pole four-wire, four-pole 400V, and the line with rated current up to 63A. When a person gets electrocuted or the grid leakage current exceeds the specified value, the residual current circuit breaker can quickly cut off the faulty power supply in an extremely short time, protecting personal safety and electrical equipment, and also providing overload and short-circuit protection for the line. It can also be used for infrequent switching of the line. This product is applicable to various places such as industry, commerce, high-rise buildings, and residential buildings. It complies with the standards GB/T 16917.1 and IEC 61009-1, and has obtained CCC, CE, and SEMKO certifications.

Detailed Parameters

Parameter CategoryParameter ItemParameter Value
System ParametersRated Voltage (Ue)AC 230V (IP+N, 2P), AC 400V (3P, 3P+N, 4P)
Rated Current (In)50A, 63A
Rated Insulation Voltage (Ui)500V
Rated Impulse Withstand Voltage (Uimp)4kV
Rated Residual Operating Current0.03A, 0.1A, 0.3A
Rated Non-operating Residual Current0.15A
Residual Current Trip TypeAC Type
Number of Poles1P+N, 2P, 3P, 3P+N, 4P
Residual Current Tripping FormC Type
Residual Current Breaking Capacity (IΔn)6000A
Residual Current Protection and Breaking Capacity (IΔm)500A (A≤50A); 630A (A>63A)
Total Switching Time for Residual CurrentSee Table 2
Performance IndicatorsOvercurrent Protection CharacteristicsSee Table 3, Figure 1
Mechanical and Electrical LifeSee Table 4
Insulated WiresSee Table 5
Dimensions and Installation DimensionsSee Figure 2, Figure 3
Pollution LevelLevel 2
Protection LevelIP20
Installation CategoryCategory II
Communication
Protection Functions
Installation

Requirement confirmation

Application, rating, quantity and drawings are checked first.

Factory matching

Supplier capacity, certificates and production slot are reviewed.

Order transaction

Confirm commercial terms, sign the commercial contract, and confirm the related document checklist.

Shipment control

Packing photos, inspection records and delivery status are tracked.