NB1LE-40 Residual Current Operated Circuit Breaker

Product category:
Residual Current Circuit Breaker (RCCB)
Product code:
P-355
Model:
NB1LE-40

Function & Use (Application Scenarios)

Terminal electrical appliances, residual current operated circuit breakers are mainly suitable for AC 50Hz, rated voltage single-pole two-wire, two-pole 230V, three-pole, three-pole four-wire, four-pole 400V circuits, when a person is electrocuted or the leakage current of the power grid exceeds the specified value

Surprise on inquiry

Product highlights

  • Overload protection is reliable
  • Short-circuit protection capability
  • Leakage protection support
  • Engineering Application Compatibility
  • Stable and reliable operation

Model

NB1LE-40

Main Product Parameters

CategorySwitchgearSecondary CategoryResidual Current Operated Circuit Breaker

Product details

Function and Application

The NB1LE-40 residual current circuit breaker is suitable for AC 50Hz, rated voltage single-pole two-wire, two-pole 230V, three-pole, three-pole four-wire, four-pole 400V circuits, and can cut off the faulty power supply in a very short time when a person gets electrocuted or the leakage current of the power grid exceeds the specified value, thus protecting personal safety and electrical equipment. It also provides overload and short-circuit protection for the circuit, and can be used for infrequent switching of the circuit. The product is applicable to various places such as industry, commerce, high-rise buildings, and residential buildings. It complies with the standards GB/T 16917.1 and IEC 61009-1, and has obtained CCC certification.

Details Parameters

Parameter CategoryParameter ItemParameter Value
System ParametersRated Voltage (Up)AC 230V (1P+N, 2P), AC 400V (3P, 3P+N, 4P)
Rated Current (In)6A, 10A, 16A, 20A, 25A, 32A, 40A
Rated Insulation Voltage (Ui)500V
Rated Impulse Withstand Voltage (Uimp)4kV
Rated Residual Operating Current (Imr)0.03A, 0.1A, 0.3A
Rated Non-operating Residual Current (Imnr)0.5IΔn
Residual Current Protection TypeAC Type
Poles1P+N, 2P, 3P, 3P+N, 4P
Copper Terminal TypeC Type
Rated Short Circuit Breaking Capacity (kA)6000A (NB/LE-60), 10000A (NB/LE-40H)
Residual Current Operation Characteristic CurveSee Table 2
Overcurrent Protection Characteristic CurveSee Table 1
Mechanical and Electrical LifeSee Table 4
Connecting WiresSee Table 5
Torsional Torque2.0N·m
Outline Dimensions and Installation DimensionsFigure 2, Figure 3
Pollution LevelLevel 2
Protection LevelIP20
Installation CategoryCategory III
Performance IndicatorsResidual Current Operation Disconnection Time
In(A)IΔn(A)
0.03, 0.1, 0.3 IΔn 2IΔn 5IΔn 5A-200A*
6-400.1 0.05 0.04 0.04
Note: For testing above the residual current test, the leakage current is not tested according to the specification.
Overcurrent Protection Characteristics (Reference Temperature 30°C)
Serial NumberRated Current A Initial State Test Current Specified Time Expected Result Notes
a6-40 Cold State 1.13In t≤1h No Tripping
b6-40 Immediately after the previous test 1.45In ≤1h Trip This value increases steadily within 5s and remains stable
cIn≤32 Cold State 2.55In 1s±1s Trip
dIn≤32 Cold State 2.55In 1s±120s Trip
e6-40 Cold State 5In t≤0.1s No Tripping
f6-40 Cold State 10In t≤0.1s Trip
Residual Current Characteristic Curve
Figure 1 C Type

Requirement confirmation

Application, rating, quantity and drawings are checked first.

Factory matching

Supplier capacity, certificates and production slot are reviewed.

Order transaction

Confirm commercial terms, sign the commercial contract, and confirm the related document checklist.

Shipment control

Packing photos, inspection records and delivery status are tracked.