NL1E-63 Residual Current Operated Circuit Breaker

Product category:
Residual Current Circuit Breaker (RCCB)
Product code:
P-358
Model:
NL1E-63

Function & Use (Application Scenarios)

Final electrical appliances, residual current operated circuit breakers are mainly applicable to (without overcurrent protection) AC 50/60Hz, rated voltage two-pole 230V, four-pole 400V, rated current up to 63A circuits, when a person is electrocuted or the grid leakage current exceeds the specified value, residual

Surprise on inquiry

Product highlights

  • Leakage current protection support
  • Engineering Application Compatibility
  • Stable and reliable operation
  • Easy system integration

Model

NL1E-63

Main Product Parameters

CategorySwitchgearSecondary categoryResidual Current Operated Circuit Breaker

Product details

Function and Usage

The NL1E-63 residual current circuit breaker (without overcurrent protection) is suitable for AC 50/60Hz, rated voltage of 230V for two-pole and 400V for four-pole, with a rated current up to 63A. When a person gets electrocuted or the leakage current of the power grid exceeds the specified value, the residual current circuit breaker can quickly cut off the faulty power supply in an extremely short time, protecting personal safety and electrical equipment. It can also be used for infrequent switching of circuits. The product is suitable for various places such as industry, commerce, high-rise buildings, and residential areas. It complies with the standards GB/T 16916.1 and IEC 61008-1, and has obtained CCC certification.

Detailed Parameters

Parameter CategoryParameter ItemParameter Value
System ParametersRated Voltage (Ue)AC 230V (2P), AC 400V (4P)
Rated Current (In)25A, 40A, 63A
Rated Insulation Voltage (Ui)500V
Rated Impulse Withstand Voltage (Uimp)4kV
Rated Residual Operating Current (IΔn)0.03A
Poles2P, 4P
Rated Limiting Short-Circuit Current (Inc)6000A
Rated Limiting Residual Short-Circuit Current (IΔc)6000A
Rated Making and Breaking Capacity (Im)500A (In=25, 40A): 630A (In=63A)
Rated Making and Breaking Capacity (IΔm)500A (In=25, 40A); 630A (In=63A)
Rated Non-operating Residual Current0.5IΔn
Residual Current Operation Disconnection TimeSee Table 2
Mechanical and Electrical LifeSee Table 3
Tightening Torque2.5N·m
Outline Dimensions and Installation DimensionsSee Figure 1, Figure 2
Pollution DegreeLevel 2
Protection LevelIP20
Installation CategoryCategory II
Performance IndexesDisconnection Time of Residual Current Operation
InA IΔn(A) Disconnection Time s When Residual Current (IΔ) Equals the Following Values Maximum Disconnection Time
25, 40, 63 0.03 IΔn 2IΔn 5IΔn 5A-200A 500A
0.1 0.08 0.04 0.04 0.04
Mechanical and Electrical Life
In(A) Number of Operation Cycles Load Operation Times (times) No-load Operation Times (times) Operation Frequency (times/hour)
25 2000 2000 240
40, 63 2000 1000 120
Protection FunctionsApplicable for (4~16)mm² Copper Conductor ConnectionThe wiring method uses screw tightening, with a torque of 2.5N·m.
Rated Current In(A)Copper Conductor Nominal Cross-sectional Area (mm²)
254
4010
6316

Requirement confirmation

Application, rating, quantity and drawings are checked first.

Factory matching

Supplier capacity, certificates and production slot are reviewed.

Order transaction

Confirm commercial terms, sign the commercial contract, and confirm the related document checklist.

Shipment control

Packing photos, inspection records and delivery status are tracked.