NXSCB Series Surge Protective Device Dedicated Protection Device

Product category:
Surge Protective Device (SPD)
Product code:
P-381
Model:
NXSCB

Function & Use (Application Scenarios)

Terminal electrical appliances, surge protectors are mainly applicable for the protection of low-voltage surge protectors, solving the safety hazards existing when traditional miniature circuit breakers or fuses are used as backup protection for surge protectors. This series can cut off 3A or more low short circuits in an extremely short time.

Surprise on inquiry

Product highlights

  • Short-circuit protection capability
  • Engineering Application Compatibility
  • Stable and reliable operation
  • Easy system integration

Model

NXSCB

Main Product Parameters

CategorySwitchgearSecondary CategorySurge protector

Product details

Function and Application

Specifically used for the protection of low-voltage surge protective devices, solving the safety hazards that exist when traditional miniature circuit breakers or fuses are used as backup protection for surge protective devices. This series can cut off low short-circuit currents of more than 3A in an extremely short time, and can also cut off high short-circuit currents with amplitudes up to 100kA, greatly reducing the risk of fire of the surge protective device and improving the safety of use.

Detailed Parameters

Parameter CategoryParameter ItemParameter Value
Product ModelNXSCB-I+IITest Category I and II for the matched SPD
Rated Operating Voltage (V) AC230/400
Poles 1P, 2P, 3P, 4P
Impulse Discharge Current Iimp(kA) 12.5
Rated Discharge Current In(kA) 40
Maximum Discharge Current Imax(kA) 80
Rated Short-Circuit Breaking Capacity Icn(kA) 100
Minimum Instantaneous Operation Current (I(A) 3
Voltage Protection Level Up(kV) 1.5
Protection Level IP20
Operating Environmental Temperature (℃) -40~+70
NXSCB-IITest Category II for the matched SPD
Rated Operating Voltage (V) AC230/400
Poles 1P, 2P, 3P, 4P
Impulse Discharge Current Iimp(kA) -
Rated Discharge Current In(kA) 10
Maximum Discharge Current Imax(kA) 65
Rated Short-Circuit Breaking Capacity Icn(kA) 65, 100
Minimum Instantaneous Operation Current (I(A) 3
Voltage Protection Level Up(kV) 1.5
Protection Level IP20
Operating Environmental Temperature (℃) -40~+70
Specialized Protection Device and SPD Selection TableProduct ModelRated Short-Circuit Breaking Capacity (Icn) Compatible SPD Series
NXSCB-I+II 12.5H100kA NXU-I+II 12.5kA
NXSCB-I+II 15H100kA NXU-I+II 12.5kA
NXSCB-I+II 25H100kA Other limp 25kA and below surge protective devices
NXSCB-II 2065kA NXU-II 20kA, NXU-II G 20kA
NXSCB-II 20H100kA NXU-II 20kA, NXU-II G 20kA
NXSCB-II 4065kA NXU-II 40kA, NXU-II G 40kA
NXSCB-II 40H100kA NXU-II 40kA, NXU-II G 40kA
NXSCB-II 6565kA NXU-II G 65kA
NXSCB-II 65H100kA NXU-II G 65kA
NXSCB-II 8065kA Other Imax 80kA and below Type II Surge Protective Devices
NXSCB-II 80H100kA Other Imax 80kA and below Type II Surge Protective Devices
NXSCB-II 10065kA NXU-II G 100kA
NXSCB-II 100H100kA NXU-II G 100kA
NXSCB-II 12065kA NXU-II G 120kA
NXSCB-II 120H100kA NXU-II G 120kA

Requirement confirmation

Application, rating, quantity and drawings are checked first.

Factory matching

Supplier capacity, certificates and production slot are reviewed.

Order transaction

Confirm commercial terms, sign the commercial contract, and confirm the related document checklist.

Shipment control

Packing photos, inspection records and delivery status are tracked.