NXU- II Series Surge Protector

Product category:
Surge Protective Device (SPD)
Product code:
P-388
Model:

Function & Use (Application Scenarios)

End devices, surge protectors are mainly applicable to 1 conforming to standard GB/T18802.11, suitable for engineering matching, installation and maintenance, and long-term stable operation, meeting the on-site application requirements of electrical systems.

Surprise on inquiry

Product highlights

  • Engineering Application Compatibility
  • Stable and reliable operation
  • Easy system integration

Model

Main Product Parameters

CategorySwitchgearSecondary CategorySurge protector

Product details

Function and Usage

1 Complies with standard GB/T 18802.11

Detailed Parameters

Parameter CategoryParameter ItemParameter Value
Technical Parameter ItemsTest CategoryClass II
Maximum Discharge Current Imax (kA)20, 40
Maximum Continuous Operating Voltage Uc (V~)255, 275, 320, 385, 440
Nominal Discharge Current In (kA)10, 20
Voltage Protection Level Up (kV)1.2, 1.5, 1.6, 1.8, 2.0
Pole Number1P, 2P, 3P, 4P, 1P+N, 3P+N
Connection Wire (mm²)≤ 16 (M4), ≤ 25 (M5)
Tightening Torque (N·m)1.5 (M4), 2.0 (M5)
Protection LevelIP20
DimensionsSee Figure 2 ~ Figure 3
Back-up FuseSee Table 3
Short Circuit Current Withstand Capability (kA)5
Transient Overvoltage (TOV) CharacteristicsUc: 275V, 320V, Low Voltage TOV, Withstand Mode (U1=336V, t1=5s), Fault Mode (U1=442V, t1=120min)
Uc: 385V, 440V, Low Voltage TOV, Not Applicable (U1=336V, t1=5s), Fault Mode (U1=442V, t1=120min)
Pole Number: 1P, 2P, 3P, 4P, High Voltage TOV Not Applicable
Pole Number: 1P+N, 3P+N, High Voltage TOV Fault Mode
Communication and IndicationCommunication function can be selected as needed, indication function see product indicator window
Working Status/Fault IndicationGreen (remote signal terminal 11 → 14 normally open, 11 → 12 normally closed) / Red (remote signal terminal 11 → 14 normally closed, 11 → 12 normally open)
Communication Terminal Wiring CapacityMaximum 1.5mm²
Communication Contact Switching Capacity250V/0.5A; 250V/0.1A; 75V/0.5A
Earthing SystemTTTN-C TN-S IT Note
Maximum Operation Voltage of the Grid Us.max345V253V 253V 400V Refer to IEC 60364-5-534
NXU-ⅡL-PE/N-PE Protection Mode*
Uc=275V, 320V
- 1P, 3P 2P, 4P - Not Suitable for Inductive Load
L-PE/N-PE Protection Mode
Uc=385V, 440V
2P, 4P 1P, 3P 2P, 4P 3P (440V)
L-N/N-PE Protection Mode b
Uc=255V, 275V, 320V, 385V, 440V
1P+N
3P+N - 1P+N
3P+N - It is recommended to choose 440V for inductive load
Selection of Back-up Fuse
Surge Protector ModelMaximum Discharge Current (kA)Back-up Fuse Breaking Range
Rated Current (A)
NXU-Ⅱ2063 gL/gG
40125 gL/gG

Requirement confirmation

Application, rating, quantity and drawings are checked first.

Factory matching

Supplier capacity, certificates and production slot are reviewed.

Order transaction

Confirm commercial terms, sign the commercial contract, and confirm the related document checklist.

Shipment control

Packing photos, inspection records and delivery status are tracked.