NXC-XM Series AC Contactors

Product category:
AC Contactor
Product code:
P-393
Model:
XM

Function & Use (Application Scenarios)

Motor control and protection electrical appliances, AC contactor products are mainly suitable for new, stylish appearance, compact structure. They are mainly used to frequently start and control AC motors, and to remotely connect and disconnect circuits, and can be combined with appropriate thermal overload relays to form an electromagnetic starter

Surprise on inquiry

Product highlights

  • Overload protection reliable
  • Strong breaking capacity
  • Control response is stable
  • Engineering Application Compatibility
  • Stable and reliable operation

Model

XM

Main Product Parameters

CategorySwitchgearSecondary CategoryAC contactor
ParametersRated working current Ie: 6A~100A; Rated working voltage Ue: 220V~690V; Rated insulation voltage: 690V; Pole number: 3P; Coil control method: AC

Product details

Function and Application

The new NXC-XM series AC contactor has a novel appearance and compact structure. It is mainly used for frequently starting and controlling AC motors, and for remotely connecting and disconnecting circuits. It can be combined with appropriate thermal overload relays to form an electromagnetic starter.

Detailed Description

Parameters:
Rated operating current Ie: 6A~100A
Rated operating voltage Ue: 220V~690V
Rated insulation voltage: 690V
Number of poles: 3P
Coil control method: AC

Detail Parameters

Parameter CategoryParameter ItemParameter Value
Contactor ModelNXC-06XM
NXC-09XM
NXC-12XM
NXC-16XM
NXC-18XM
NXC-22XM
Category Level06-16
Rated Free Air Release Current (HA)2020 25 25 32 32
Rated Insulation Voltage (Ue)800V800V 800V 800V 800V 800V
Rated Impulse Withstand Voltage (Uimp)8kV8kV 8kV 8kV 8kV 8kV
Rated Switching CapacitySwitching and Breaking Current (B-le) (AC-3)8kA 8kA 8kA 8kA 8kA 8kA
Starting Operating Current (A)AC-1: 220V/230V20 20 25 25 32 32
AC-3: 380V/400V6 9 12 15 18 22
AC-3: 660V/690V3.8 6.6 8.9 8.9 12 14
Rated Control Power (AC-3 kW)AC-3: 220V/230V1.5 2.2 3 4 5.5 7.5
AC-3: 380V/400V2.2 4 5.5 7.5 7.5 11
AC-3: 660V/690V3 5.5 7.5 7.5 11 11
Electrical Life (times in 10,000)AC-3120 120 120 120 120 120
Mechanical Life (times in 10,000)1200 1200 1200 1200 1200 1200
Main Contact Structure Type3 Normally Open 3 Normally Open 3 Normally Open 3 Normally Open 3 Normally Open 3 Normally Open
SCPD Compatible Auxiliary ContactgG20gG20 gG25 gG25 gG32 gG32
Number of Built-in Auxiliary Contacts3P4P - - - -
Control CircuitContactor ModelNXC-06XM NXC-09XM NXC-12XM NXC-16XM NXC-18XM NXC-22XM
Electrical Connection (mm²)Prepared Soft Wire: 1 piece Preparing Soft Wire: 1+2.5 pieces Preparing Soft Wire: 2 pieces Preparing Soft Wire: 1+1.5 pieces Preparing Soft Wire: 1.5-4 pieces Preparing Soft Wire: 1.5-6 pieces
Hard Wire: 1 piece Hard Wire: 1 piece Hard Wire: 2 pieces Hard Wire: 1 piece Hard Wire: 1.5-6 pieces Hard Wire: M3.5
Tightening Screw SizeM5.5 M5.5 M5.5 M5.5 M3.5 M1.2
Tightening Torque (N·m)
Control Circuit TerminalElectrical Connection (mm²)Prepared Soft Wire: 1 piece Prepared Soft Wire: 1+1.5 pieces Prepared Soft Wire: 2 pieces Prepared Soft Wire: 1+1.5 pieces Prepared Soft Wire: 1.5-6 pieces Prepared Soft Wire: 1.5-6 pieces
Hard Wire: 1 piece Hard Wire: 1 piece Hard Wire: 2 pieces Hard Wire: 1 piece Hard Wire: 1.5-6 pieces Hard Wire: M3.5
Tightening Screw SizeM5.5 M5.5 M5.5 M5.5 M3.5 M1.2
Tightening Torque (N·m)
Controller ModelNXC-06XMNXC-09XM NXC-12XM NXC-16XM NXC-18XM NXC-22XM
Operating RangeEngage: (70%-200%)Us1.5-6 1.5-6 1.5-6 1.5-6 1.5-6 1.5-6
Disengage: (20%-65%)Us
Average Coil Power Consumption (VA)Start: 50-70
Hold: ≤9.0
Precision (%)AC-DC: 1-3
DC-DC: -
Main Contact Operation Time (ms)Engage: 12-40
Disengage: 25-45
Contactor ModelNXC-25XMNXC-32XM NXC-38XM NXC-40XM NXC-50XM NXC-65XM NXC-75XM NXC-85XM NXC-100XM
Category Level25-3840 50 60 80 80 90 100 125
Rated Free Air Release Current (HA)4050 50 60 60 80 80 90 100
Rated Insulation Voltage (Ue)800V800V 800V 800V 800V 800V 800V 800V 800V
Rated Impulse Withstand Voltage (Uimp)10kV10kV 10kV 10kV 10kV 10kV 10kV 10kV 10kV
Rated Control Power (AC-3 kW)AC-1: 220V/230V40 50 50 60 80 80 90 100 125
AC-3: 380V/400V25 32 38 40 50 50 65 75 85 100
AC-3: 660V/690V18 22 22 34 39 42 42

Requirement confirmation

Application, rating, quantity and drawings are checked first.

Factory matching

Supplier capacity, certificates and production slot are reviewed.

Order transaction

Confirm commercial terms, sign the commercial contract, and confirm the related document checklist.

Shipment control

Packing photos, inspection records and delivery status are tracked.