NXCQ AC Contactor (Mechanical Emergency Start Device)

Product category:
AC Contactor
Product code:
P-397
Model:

Function & Use (Application Scenarios)

Motor control and protection devices, AC contactor products are mainly applicable to fire water supply systems designed specifically, with the function of manual mechanical emergency start of fire pumps, in compliance with GB/T50974-2014 Technical Code for Fire Water Supply and Hydrant Systems

Surprise on inquiry

Product highlights

  • Reliable protection level
  • Engineering Application Compatibility
  • Stable and reliable operation
  • Easy system integration

Model

Main Product Parameters

CategorySwitchgearSecondary CategoryAC contactor

Product details

Function and Usage

The NXCQ AC contactor (mechanical emergency start device) is a product specifically developed for fire water supply systems, with the function of manually starting the fire pump mechanically, and it complies with the requirements for manual mechanical emergency start functions in GB/T 50974-2014 "Technical Code for Fire Water Supply and Fire Hydrant Systems".

Detailed Parameters

Parameter CategoryParameter ItemParameter Value
Product ModelNXCQ38, 65, 100, 225, 400
Rated Operating Current (A)25, 32, 38, 40, 50, 65, 75, 85, 100, 120, 160, 185, 225, 265, 330, 400
Agreed Free Air Heating Current Ith(A)40, 50, 50, 60, 80, 80, 90, 100, 110, 200, 200, 275, 275, 315, 380, 450
Rated Insulation Voltage Ui (V)690
Rated Impulse Withstand Voltage Uimp (kV)6
Rated Make CapacityMake Current: 10×le (AC-3) or 12×(AC-4)
Rated Break CapacityBreak Current: 8×le (AC-3) or 10×(AC-4)
Rated Operating Current le(A)AC-3 380V/400V25, 32, 38, 40, 50, 65, 75, 85, 100, 120, 160, 185, 225, 265, 330, 400
AC-4 380V/400V25, 32, 32, 40, 50, 65, 75, 85, 100, 120, 160, 160, 185, 265, 330, 330
Rated Control PowerAC-3 Electrical Life (times 10,000)120, 100, 80, 120, 80
AC-3 Electrical Life (times 10,000)11, 15, 18.5, 18.5, 22, 30, 37, 37, 45, 55, 75, 90, 110, 132, 160, 200
Contactor Mechanical Life (times 10,000)1000, 900, 650, 600, 600
Mechanical Life of Manual Operation Mechanism (times)>3000
Main Contact Structure Form3 Normally Open
Number of Built-in Auxiliary Contacts1 Normally Open 1 Normally Closed2 Normally Open 2 Normally Closed
Main Circuit WiringSoft Wire1 Wire 1.5~10, 6~25, 10~35, 10~150, 50~240
2 Wires 1.5~6, 4~10, 6~16, 1~75, /
Hard Wire1 Wire 1.5~10, 6~25, 10~35, 10~150, 50~240
2 Wires 1.5~6, 4~10, 6~16, 10~75, 50~240
Size of Tightening ScrewsM4, M8, M8, M6, M8, M10, M10
Tightening Torque (N·m)1.2, 6, 6, 10, 14, 14
Control Circuit WiringSoft Wire1 Wire 1~4, 2 Wires 1~4
2 Wires 1~4, 2 Wires 1~4
Hard Wire1 Wire 1~4, 2 Wires 1~4
Size of Tightening ScrewsM3.5
Tightening Torque (N·m)0.8
Coil Control Power SupplyAC 50Hz220 (other voltages require customization)
Action RangeEngagement(70%~ 120%) Us, (75%~ 120%) Us
Release(20%~65%) Us, (20%~70%) Us
Average Power Consumption of Coil (VA)Start50~70, 160~210, 190~250, 500, 600
Hold11.4, 17~25, 17~30, 50, 11
Thermal Loss (W)AC1~3, 4~8, 6~10, 30~50, 3~6

Requirement confirmation

Application, rating, quantity and drawings are checked first.

Factory matching

Supplier capacity, certificates and production slot are reviewed.

Order transaction

Confirm commercial terms, sign the commercial contract, and confirm the related document checklist.

Shipment control

Packing photos, inspection records and delivery status are tracked.