Function & Use (Application Scenarios)

Motor control and protection electrical appliances, AC contactor products are mainly suitable for AC 50Hz, rated insulation voltage of 690V, when the rated working voltage is 380V under AC-3 usage category, the rated working current up to 95A in power systems, as for long-distance connection and disconnection

Surprise on inquiry

Product highlights

  • Strong breaking capacity
  • Control response is stable
  • Reliable protection level
  • Engineering Application Compatibility
  • Stable and reliable operation

Model

NCX1

Main Product Parameters

CategorySwitchgearSecondary CategoryAC contactor
ParametersRated operating current Ie: 9A~95A; Pole number: 3P; Operating ambient temperature: -35℃~+70℃

Product details

Function and Purpose

The NCX1 series dust-proof AC contactors are mainly used in power systems with an AC frequency of 50Hz, a rated insulation voltage of 690V, and a rated working voltage of 380V under the AC-3 usage category, with a rated working current up to 95A. They are used for remotely connecting and disconnecting circuits, and are suitable for controlling the start, stop, and reversal of AC motors. They can also be combined with appropriate thermal relays to form electromagnetic starters for protecting circuits that may experience overload.

Detail Description

Parameters:
Rated Working Current Ie: 9A~95A
Number of Poles: 3P
Working Ambient Temperature: -35℃~+70℃

Detail Parameters

Parameter CategoryParameter ItemParameter Value
Contactor ModelNCX1-9, 9/22, 9/22N
NCX1-12, 12/22, 12/22N
NCX1-18, 18/22, 18/22N
NCX1-22, 22/22, 22/22N
NCX1-25, 25/22, 25/22N
NCX1-32, 32/22, 32/22N
NCX1-38, 38/22, 38/22N
NCX1-40
NCX1-50
NCX1-65
NCX1-80
NCX1-95
Legend
Frame Rating9-18
22-38
40-65
80-95
Rated Free Air Heating Current Ith(A)25
50
70
80
125
Rated Insulation Voltage Uie(V)690
Rated Impulse Withstand Voltage Uimp(kV)8
Rated Limiting Short Circuit Current (kA)10
50
50
50
50
Impedance Z(Ω)≤ 5.0×10⁻⁴
Rated Making CapacityMaking Current: 10×le(AC-3) or 12×le(AC-4)
Rated Breaking CapacityRated Working Current le(A)
AC-3, 380V9
AC-4, Interlock, 380V9
AC-3, 660V6.6
AC-4, Interlock, 660V6.6
AC-3, 220V2.2
AC-3, 380V4
AC-3, 660V5.5
AC-4, 380V3
AC-4, 660V7.5
AC-4, Interlock, 220V4
AC-4, Interlock, 380V12
AC-4, Interlock, 660V12
AC-4, Interlock, 220V14
AC-4, Interlock, 380V18
AC-4, Interlock, 660V14
AC-4, Interlock, 220V22
AC-4, Interlock, 380V22
AC-4, Interlock, 660V22
AC-4, Interlock, 220V32
AC-4, Interlock, 380V38
AC-4, Interlock, 660V38
AC-4, Interlock, 220V40
AC-4, Interlock, 380V50
AC-4, Interlock, 660V50
AC-4, Interlock, 220V65
AC-4, Interlock, 380V65
AC-4, Interlock, 660V65
AC-4, Interlock, 220V80
AC-4, Interlock, 380V80
AC-4, Interlock, 660V80
AC-4, Interlock, 220V95
AC-4, Interlock, 380V95
AC-4, Interlock, 660V95
Rated Control Power (KW)AC-3, 220V120
AC-3, 380V120
AC-3, 660V100
AC-4, 220V1200
AC-4, 380V1200
AC-4, 660V1200
See the electrical life curve diagram
See the electrical life curve diagram
See the electrical life curve diagram
Electrical life (times in ten thousand)AC-3120
AC-41200
See the electrical life curve diagram
Mechanical life (times in ten thousand)AC-31200
AC-41200
See the electrical life curve diagram
Operation frequency (times/hour)Electrical life1200
600
Mechanical life3600
3600
Fuse model matched with SCPDRT36-00 32RT36-00 63
RT36-00 80
RT36-00 100
Self-matching thermal overload relay modelNXR-25NXR-25, NXR-38
NXR-38
NXR-100
NXR-100
Number of built-in auxiliary contactsNCX1 default 1 normally open 1 normally closed, NCX1-□ / □ indicates 2 normally closed
Auxiliary contact rated heating current (A)10
Auxiliary contact rated insulation voltage (V)690
Auxiliary contact rated operating current (A)AC-15 380V/220V0.95
DC-13 110V/220V0.15
Arc distance (mm)0
≤ 10

Requirement confirmation

Application, rating, quantity and drawings are checked first.

Factory matching

Supplier capacity, certificates and production slot are reviewed.

Order transaction

Confirm commercial terms, sign the commercial contract, and confirm the related document checklist.

Shipment control

Packing photos, inspection records and delivery status are tracked.