CJX1-K Series AC Vacuum Contactor

Product category:
AC Contactor
Product code:
P-407
Model:
CJX1-K

Function & Use (Application Scenarios)

Motor control and protection electrical appliances, AC contactors are mainly applicable to (hereinafter referred to as contactors), which are mainly used in AC 50Hz, rated insulation voltage of 1000V, and in the AC-3 usage category, when the rated operating voltage is 380V, the rated operating current is up to 820A in the circuit.

Surprise on inquiry

Product highlights

  • Overload protection is reliable
  • Strong breaking capacity
  • Control response is stable
  • Engineering Application Compatibility
  • Stable and reliable operation

Model

CJX1-K

Main Product Parameters

CategorySwitchgearSecondary CategoryAC Contactor
ParametersRated current: 225~820A; Operating temperature: -25~+60℃; Control method: AC/DC universal

Product details

Function and Usage

The CJX1-K series AC vacuum contactor (hereinafter referred to as the contactor) is mainly used in AC circuits with a frequency of 50Hz, a rated insulation voltage of 1000V, and an rated operating voltage of 380V under the AC-3 usage category, with a rated operating current up to 820A. It is used for remote connection and disconnection of circuits, and can be combined with appropriate thermal overcurrent relays or electronic protection devices to form a vacuum electromagnetic starter. It is especially suitable for forming a flameproof vacuum electromagnetic starter. It is widely used in places such as mines, smelting, oil drilling, storage, chemical industry, military industry, textile, construction, etc., which are flammable, explosive, or have harsh environments.

Detailed Description

Parameters:
Rated Current: 225~820A
Operating Temperature: -25~+60℃
Control Method: AC/DC Universal

Details Parameters

Parameter CategoryParameter ItemParameter Value
Contactor ModelCJX1-225/22K
Legend
Rated Free Air Heating Current Ith(A)330
Rated Insulation Voltage Ui(V)1000
Rated Impact Withstand Voltage(kV)6
Rated Limiting Short Circuit Current(kA)50
Phase Impedance Z(Ω)≤5.0×10⁻³
Rated Closing CapacityClosing Current: 10×le(AC-3)
Rated Breaking CapacityBreaking Current: 8×le(AC-3)
AC-3 Rated Working Current Ie(A)380V/400V/660V/690V/1000V
225
AC-3 Rated Control Power(kW)220V
380V
660V
380V/440V
660V/690V
1000V
Mechanical Life (times/h)Operating Frequency: 1200 times ×10⁶
Times ×10⁶: 700
AC-3 Electrical Life (times/h)Operating Frequency: 600 times ×10⁶
Times ×10⁶: 200
Arc Distance(mm)0
SCPD Compatible Circuit BreakerRT36-2 400A
Corresponding Thermal Overload RelayNXR-630
Basic Parameters of Auxiliary ContactsAC-15: 380V/0.95A, DC-13: 220V/0.15A, Ut660V, Ith10A
Number of Auxiliary ContactsTwo Normally Open and Two Normally Closed
Electromagnetic System CapabilityCoil Control Power Supply(V)AC (50Hz~60Hz)/DC: 110, 220, 380
Action RangeClose: Cold State: (65%~110%)Us; AC: (20%~60%)Us; DC: (10%~60%)Us
Release
Coil Holding Power(VA)Start: 95
Hold: 7.4
Wiring CapabilityMain Circuit WiringNumber: 1
Wire Cross Section (mm²): 185
Tightening Screw Size: M10
Tightening Torque (N·m): 10
Number: 1-2
Wire Cross Section (mm²): 185~240
Tightening Screw Size: M12
Tightening Torque (N·m): 14
Auxiliary Circuit WiringNumber: 1-2
Wire Cross Section (mm²): 0.5~1.5
Tightening Screw Size: M3.5
Tightening Torque (N·m): 0.8
Parameter CategoryParameter ItemParameter Value
Contactor ModelCJX1-265/22K
Legend
Rated Free Air Heating Current Ith(A)330
Rated Insulation Voltage Ui(V)1000
Rated Impact Withstand Voltage(kV)6
Rated Limiting Short Circuit Current(kA)50
Phase Impedance Z(Ω)≤5.0×10⁻³
Rated Closing CapacityClosing Current: 10×le(AC-3)
Rated Breaking CapacityBreaking Current: 8×le(AC-3)
AC-3 Rated Working Current Ie(A)380V/400V/660V/690V/1000V
265
AC-3 Rated Control Power(kW)220V
380V
660V
380V/440V
660V/690V
1000V
Mechanical Life (times/h)Operating Frequency: 1200 times ×10⁶
Times ×10⁶: 700
AC-3 Electrical Life (times/h)Operating Frequency: 600 times ×10⁶
Times ×10⁶: 200
Arc Distance(mm)0
Circuit breaker used with SCPDRT36-3 630A
Corresponding thermal overcurrent relayNXR-630
Basic parameters of auxiliary contactsAC-15: 380V/0.95A, DC-13: 220V/0.15A, Ut660V, Ith10A
Number of auxiliary contactsTwo normally open and two normally closed
Electromagnetic system capabilityCoil control power supply (V)AC (50Hz~60Hz)/DC: 110, 220, 380
Action rangeEngagement: Cold state: (65%~110%)Us; AC: (20%~60%)Us; DC: (10%~60%)Us
Release
Coil holding power (VA)Start: 95
Hold: 7.4
Wiring capabilityMain circuit wiringNumber of wires: 1
Cross-sectional area (mm²): 185
Fastening screw size: M10
Fastening torque (N·m): 10
Number of wires: 1-2
Cross-sectional area (mm²): 185~240
Fastening screw size: M12
Fastening torque (N·m): 14
Auxiliary circuit wiringNumber of wires: 1-2
Cross-sectional area (mm²): 0.5~1.5
Fastening screw size: M3.5
Fastening torque (N·m): 0.8
Parameter classificationParameter itemParameter value
Contactor modelCJX1-300/22K
Figure legend
Agreed free air heating current Ith (A)330
Rated insulation voltage Ui (V)1000
Rated impulse withstand voltage (kV)6
Rated short-circuit current (kA)50
Pole impedance Z (Ω)≤5.0×10⁻³
Rated making capacityMaking current: 10×le(AC-3)
Rated breaking capacityBreaking current: 8×le(AC-3)

Requirement confirmation

Application, rating, quantity and drawings are checked first.

Factory matching

Supplier capacity, certificates and production slot are reviewed.

Order transaction

Confirm commercial terms, sign the commercial contract, and confirm the related document checklist.

Shipment control

Packing photos, inspection records and delivery status are tracked.