| Contactor Model | CJX1-225/22K |
| Legend | |
| Rated Free Air Heating Current Ith(A) | 330 |
| Rated Insulation Voltage Ui(V) | 1000 |
| Rated Impact Withstand Voltage(kV) | 6 |
| Rated Limiting Short Circuit Current(kA) | 50 |
| Phase Impedance Z(Ω) | ≤5.0×10⁻³ |
| Rated Closing Capacity | Closing Current: 10×le(AC-3) |
| Rated Breaking Capacity | Breaking Current: 8×le(AC-3) |
| AC-3 Rated Working Current Ie(A) | 380V/400V/660V/690V/1000V |
| | 225 |
| AC-3 Rated Control Power(kW) | 220V |
| | 380V |
| | 660V |
| | 380V/440V |
| | 660V/690V |
| | 1000V |
| Mechanical Life (times/h) | Operating Frequency: 1200 times ×10⁶ |
| | Times ×10⁶: 700 |
| AC-3 Electrical Life (times/h) | Operating Frequency: 600 times ×10⁶ |
| | Times ×10⁶: 200 |
| Arc Distance(mm) | 0 |
| SCPD Compatible Circuit Breaker | RT36-2 400A |
| Corresponding Thermal Overload Relay | NXR-630 |
| Basic Parameters of Auxiliary Contacts | AC-15: 380V/0.95A, DC-13: 220V/0.15A, Ut660V, Ith10A |
| Number of Auxiliary Contacts | Two Normally Open and Two Normally Closed |
| Electromagnetic System Capability | Coil Control Power Supply(V) | AC (50Hz~60Hz)/DC: 110, 220, 380 |
| Action Range | Close: Cold State: (65%~110%)Us; AC: (20%~60%)Us; DC: (10%~60%)Us |
| Release | |
| Coil Holding Power(VA) | Start: 95 |
| | Hold: 7.4 |
| Wiring Capability | Main Circuit Wiring | Number: 1 |
| | Wire Cross Section (mm²): 185 |
| | Tightening Screw Size: M10 |
| | Tightening Torque (N·m): 10 |
| | Number: 1-2 |
| | Wire Cross Section (mm²): 185~240 |
| | Tightening Screw Size: M12 |
| | Tightening Torque (N·m): 14 |
| Auxiliary Circuit Wiring | Number: 1-2 |
| | Wire Cross Section (mm²): 0.5~1.5 |
| | Tightening Screw Size: M3.5 |
| | Tightening Torque (N·m): 0.8 |
| Parameter Category | Parameter Item | Parameter Value |
| Contactor Model | CJX1-265/22K |
| Legend | |
| Rated Free Air Heating Current Ith(A) | 330 |
| Rated Insulation Voltage Ui(V) | 1000 |
| Rated Impact Withstand Voltage(kV) | 6 |
| Rated Limiting Short Circuit Current(kA) | 50 |
| Phase Impedance Z(Ω) | ≤5.0×10⁻³ |
| Rated Closing Capacity | Closing Current: 10×le(AC-3) |
| Rated Breaking Capacity | Breaking Current: 8×le(AC-3) |
| AC-3 Rated Working Current Ie(A) | 380V/400V/660V/690V/1000V |
| | 265 |
| AC-3 Rated Control Power(kW) | 220V |
| | 380V |
| | 660V |
| | 380V/440V |
| | 660V/690V |
| | 1000V |
| Mechanical Life (times/h) | Operating Frequency: 1200 times ×10⁶ |
| | Times ×10⁶: 700 |
| AC-3 Electrical Life (times/h) | Operating Frequency: 600 times ×10⁶ |
| | Times ×10⁶: 200 |
| Arc Distance(mm) | 0 |
| Circuit breaker used with SCPD | RT36-3 630A |
| Corresponding thermal overcurrent relay | NXR-630 |
| Basic parameters of auxiliary contacts | AC-15: 380V/0.95A, DC-13: 220V/0.15A, Ut660V, Ith10A |
| Number of auxiliary contacts | Two normally open and two normally closed |
| Electromagnetic system capability | Coil control power supply (V) | AC (50Hz~60Hz)/DC: 110, 220, 380 |
| Action range | Engagement: Cold state: (65%~110%)Us; AC: (20%~60%)Us; DC: (10%~60%)Us |
| Release | |
| Coil holding power (VA) | Start: 95 |
| | Hold: 7.4 |
| Wiring capability | Main circuit wiring | Number of wires: 1 |
| | Cross-sectional area (mm²): 185 |
| | Fastening screw size: M10 |
| | Fastening torque (N·m): 10 |
| | Number of wires: 1-2 |
| | Cross-sectional area (mm²): 185~240 |
| | Fastening screw size: M12 |
| | Fastening torque (N·m): 14 |
| Auxiliary circuit wiring | Number of wires: 1-2 |
| | Cross-sectional area (mm²): 0.5~1.5 |
| | Fastening screw size: M3.5 |
| | Fastening torque (N·m): 0.8 |
| Parameter classification | Parameter item | Parameter value |
| Contactor model | CJX1-300/22K |
| Figure legend | |
| Agreed free air heating current Ith (A) | 330 |
| Rated insulation voltage Ui (V) | 1000 |
| Rated impulse withstand voltage (kV) | 6 |
| Rated short-circuit current (kA) | 50 |
| Pole impedance Z (Ω) | ≤5.0×10⁻³ |
| Rated making capacity | Making current: 10×le(AC-3) |
| Rated breaking capacity | Breaking current: 8×le(AC-3) |