NC2 Series AC Contactors

Product category:
AC Contactor
Product code:
P-409
Model:
NC2

Function & Use (Application Scenarios)

Motor control and protection electrical appliances, AC contactor products are mainly applicable to (hereinafter referred to as contactors), which are mainly used in circuits with AC 50Hz or 60Hz, rated working voltage up to 690V, and rated working current up to 800A, for the purpose of remotely connecting and disconnecting circuits, and can be used with suitable

Surprise on inquiry

Product highlights

  • Overload protection reliable
  • Strong breaking capacity
  • Control response is stable
  • Engineering Application Compatibility
  • Stable and reliable operation

Model

NC2

Main Product Parameters

CategorySwitchgearSecondary CategoryAC contactor
ParametersRated current: 125~800A; Pole number: 3P, 4P; Control method: AC, DC

Product details

Function and Use

The NC2 series AC contactor (hereinafter referred to as the contactor) is mainly used in circuits with an AC frequency of 50Hz or 60Hz, a rated operating voltage up to 690V, and a rated operating current up to 800A. It is used to remotely connect and disconnect circuits, and can be combined with appropriate thermal overload relays to form an electromagnetic starter to protect circuits that may experience operational overloads.

Detailed Description

Parameters:
Rated Current: 125~800A
Number of Poles: 3P, 4P
Control Method: AC, DC

Detail Parameters

<
Parameter CategoryParameter ItemParameter Value
Contactor ModelNC2-115(Z)
Frame Rating*115~150
Rated Operating Current (A)AC-3 380V/400V200
AC-3 660V/690V115
AC-4 380V/400V86
AC-4 660V/690V115
Maximum Power of Three-phase Squirrel-cage Motor Controlled (kW)AC-3 380V/400V55
AC-3 660V/690V80
AC-4 380V/400V55
AC-4 660V/690V80
Number of Operations per Hour (times/h)AC-31200
AC-41200
Mechanical Life (ten thousand times)1000
Selected Fuse (SCPD)ModelgG250
Rated Current (A)250
Contactor ModelNC2-150(Z)
Frame Rating*115~150
Rated Operating Current (A)AC-3 380V/400V250
AC-3 660V/690V150
AC-4 380V/400V108
AC-4 660V/690V150
Maximum Power of Three-phase Squirrel-cage Motor Controlled (kW)AC-3 380V/400V75
AC-3 660V/690V100
AC-4 380V/400V75
AC-4 660V/690V100
Number of Operations per Hour (times/h)AC-31200
AC-41200
Mechanical Life (ten thousand times)1000
Selected Fuse (SCPD)ModelgG250
Rated Current (A)250
Contactor ModelNC2-185(Z)
Frame Rating*185~225
Rated Operating Current (A)AC-3 380V/400V275
AC-3 660V/690V185
AC-4 380V/400V118
AC-4 660V/690V185
Maximum Power of Three-phase Squirrel-cage Motor Controlled (kW)AC-3 380V/400V90
AC-3 660V/690V110
AC-4 380V/400V90
AC-4 660V/690V110
Number of Operations per Hour (times/h)AC-3600
AC-4100
Mechanical Life (ten thousand times)600
Selected Fuse (SCPD)ModelgG315
Rated Current (A)315
Contactor ModelNC2-225(Z)
Frame Rating*185~225
Rated Operating Current (A)AC-3 380V/400V275
AC-3 660V/690V225
AC-4 380V/400V137
AC-4 660V/690V225
Maximum Power of Three-phase Squirrel-cage Motor Controlled (kW)AC-3 380V/400V110
AC-3 660V/690V129
AC-4 380V/400V110
AC-4 660V/690V129
Number of Operations per Hour (times/h)AC-3600
AC-4100
Mechanical Life (ten thousand times)600
Selected Fuse (SCPD)ModelgG315
Rated Current (A)315
Contactor ModelNC2-265(Z)
Frame Rating*185~225
Rated Operating Current (A)AC-3 380V/400V350
AC-3 660V/690V265
AC-4 380V/400V170
AC-4 660V/690V265
Maximum power of three-phase squirrel-cage motor that can be controlled (kW)AC-3 380V/400V132
AC-3 660V/690V160
AC-4 380V/400V132
AC-4 660V/690V160
Number of operations per hour (times/h)AC-3600
AC-480
Mechanical life (ten thousand times)600
Selected fuse (SCPD)ModelgG355
Rated current (A)355
Contactor modelNC2-330(Z)
Frame rating*185~225
Rated operating current (A)AC-3 380V/400V380
AC-3 660V/690V330
AC-4 380V/400V235
AC-4 660V/690V330
Maximum power of three-phase squirrel-cage motor that can be controlled (kW)AC-3 380V/400V160
AC-3 660V/690V220
AC-4 380V/400V160
AC-4 660V/690V220
Number of operations per hour (times/h)AC-3600
AC-480
Mechanical life (ten thousand times)600
Selected fuse (SCPD)ModelgG500
Rated current (A)500
Contactor modelNC2-400(Z)
Frame rating*185~225
Rated operating current (A)AC-3 380V/400V400
AC-3 660V/690V500

Requirement confirmation

Application, rating, quantity and drawings are checked first.

Factory matching

Supplier capacity, certificates and production slot are reviewed.

Order transaction

Confirm commercial terms, sign the commercial contract, and confirm the related document checklist.

Shipment control

Packing photos, inspection records and delivery status are tracked.