NR8 Series Thermal Overload Relays

Product category:
Motor protection circuit breaker
Product code:
P-412
Model:
NR8

Function & Use (Application Scenarios)

Motor control and protection devices, thermal relays are mainly applicable to (hereinafter referred to as thermal relays) AC 50Hz/60Hz, voltage up to 690V, current 0.1A~630A, long-term or intermittent long-term operation of AC motors for overload and phase failure protection. Thermal

Surprise on inquiry

Product highlights

  • Reliable overload protection
  • Convenient installation and maintenance
  • Engineering Application Compatibility
  • Stable and reliable operation
  • Easy system integration

Model

NR8

Main Product Parameters

CategorySwitchgearSecondary CategoryMotor protection circuit breaker
ParametersSet current range: 0.1~630A; Trip level: 10A; Installation method: Plug-in installation, Independent installationAdvantages/Core Features01 Wide setting current range; can meet more load matching; 02 Electronic design; accurate and reliable operation, preventing relay misoperation; 03 Integral structure; more robust

Product details

Function and Application

The NR8 series thermal overload relay (hereinafter referred to as the thermal relay) is suitable for AC motors with a frequency of 50Hz/60Hz, voltage up to 690V, and current 0.1A~630A for long-term or intermittent long-term operation, for overload and phase failure protection. The thermal relay also has temperature compensation, action indication, automatic and manual reset, stop functions, and the product performance is stable and reliable. Compliance standards: GB/T14048.4, IEC60947-4-1. The thermal relay is installed by plug-in with a contactor.

Details Description

Parameters:
Set current range: 0.1~630A
Tripping level: 10A
Installation method: Plug-in installation, independent installation

Advantages/Core Functions:
01 Wide set current range
Can meet more load matching
02 Electronic design
Accurate and reliable action, preventing relay misoperation
03 Integrated structure
More durable

Detailed Parameters

Parameter CategoryParameter ItemParameter Value
NR8-16NR8-38 NR8-100 NR8-200 NR8-630
Current Rating1638 100 200 630
Rated Insulation Voltage V690690 690 690 690
Phase Failure ProtectionYesYes Yes Yes Yes
Manual and Automatic ResetYesYes Yes Manual Manual
Temperature CompensationYesYes Yes Yes Yes
Tripping IndicationYesYes Yes Yes Yes
Test ButtonYesYes Yes Yes Yes
Stop ButtonYesYes Yes Yes Yes
Installation MethodPlug-inPlug-in Plug-in Independent Independent
Auxiliary Contact1NO+1NC1NO+1NC 1NO+1NC 1NO+1NC 1NO+1NC
AC-15 230V Rated Current A\ \ \ 2.5 2.5
AC-15 380V/400V Rated Current A1.5 1.5 1.5 1.5 1.5
DC-13 220V Rated Current A0.2 0.2 0.2 0.2 0.2
Conductor Cross-sectional Area mm²Main CircuitSingle-core or stranded wire 1~2.5 1~10 6~35 25~98 50~2×185
Terminal Screw M3.5 M4 M4 M8 M10
Auxiliary CircuitSingle-core or stranded wire 1~2.5 1~2.5 1~2.5 1~2.5 1~2.5
Terminal Screw M3.5 M3.5 M3.5 M3.5 M3.5

Requirement confirmation

Application, rating, quantity and drawings are checked first.

Factory matching

Supplier capacity, certificates and production slot are reviewed.

Order transaction

Confirm commercial terms, sign the commercial contract, and confirm the related document checklist.

Shipment control

Packing photos, inspection records and delivery status are tracked.