Motor control and protection devices, thermal relays products are mainly applicable to (hereinafter referred to as thermal relays) which are mainly used in AC 50Hz/60Hz, rated operating voltage 690V and below, current 0.1A to 80A circuits, as overload and phase failure protection for three-phase AC motors

Surprise on inquiry

Product highlights

  • Overload protection is reliable
  • Convenient installation and maintenance
  • Engineering Application Compatibility
  • Stable and reliable operation
  • Easy system integration

Model

JRS1

Main Product Parameters

CategorySwitchgearSecondary categoryMotor Protection Circuit Breaker
ParametersRated operating voltage: 0.1~80A; Trip class: 10A; Rated insulation voltage: 690V

Product details

Function and Usage

The JRS1 series thermal overload relay (hereinafter referred to as the thermal relay) is mainly used in circuits with AC 50Hz/60Hz, rated operating voltage 690V and below, current 0.1A to 80A, for the protection of three-phase AC motors against overload and phase failure. The thermal relay has phase failure protection, temperature compensation, action indication, manual reset, and stop function (the manual reset and stop function are realized through the same button). This product operates reliably. The thermal relay can be installed by plugging it with a contactor or independently. It complies with the standards: GB/T 14048.4, IEC 60947-4-1, etc. When combined, the corresponding thermal relay models are JRS1-09~25, JRS1-09~25X, JRS1-40~80, JRS1-40~80X; when installed independently (screw type), the corresponding thermal relay model is JRS1-40~80/F.

Details

Parameters:
Rated Operating Voltage: 0.1~80A
Tripping Level: 10A
Rated Insulation Voltage: 690V

Detail Parameters

Parameter CategoryParameter ItemParameter Value
JRS1-09~25JRS1-09~25X JRS1-40~80 JRS1-40~80X
System ParametersPhase Failure ProtectionYes Yes Yes Yes
Reset MethodManual Manual Manual Manual
Temperature CompensationYes Yes Yes Yes
Tripping IndicationYes Yes Yes Yes
Test FunctionYes Yes Yes Yes
Stop ButtonYes Yes Yes Yes
Tripping Level10A 10A 10A 10A
Rated Current Range (A)0.1~25 0.1~25 23~80 23~80
Compatible Mounting BaseTerminal Block JRS1-09-25 None Terminal Block JRS1-40-80 None
Enclosure Protection LevelIP00
Rated Working SystemEight-hour working system, continuous working system
Rated Insulation Voltage Ui(V)690 690 690 690
Rated Impulse Withstand Voltage Uimp(kV)6 6 6 6
Auxiliary CircuitIth A6 6 6 6
AC-15380V, 0.95A 380V, 0.95A 380V, 0.95A 380V, 0.95A
Auxiliary Contact Type1NO+1NC 1NO+1NC 1NO+1NC 1NO+1NC
Compatible Fuse Model and SpecificationgG-10A gG-10A gG-10A gG-10A
Rated Insulation Voltage Ui(V)380 380 380 380
Rated Impulse Withstand Voltage Uimp(kV)6 6 6 6

Requirement confirmation

Application, rating, quantity and drawings are checked first.

Factory matching

Supplier capacity, certificates and production slot are reviewed.

Order transaction

Confirm commercial terms, sign the commercial contract, and confirm the related document checklist.

Shipment control

Packing photos, inspection records and delivery status are tracked.