NR2 Series Thermal Relays

Product category:
Motor protection circuit breaker
Product code:
P-416
Model:
NR2

Function & Use (Application Scenarios)

Motor control and protection electrical appliances, thermal relays products are mainly applicable to NR2 series thermal overload relays (hereinafter referred to as thermal relays), which are suitable for AC 50Hz/60Hz, voltage up to 690V, current (0.1-150)A for long-term or intermittent long-term AC power

Surprise on inquiry

Product highlights

  • Reliable overload protection
  • Convenient installation and maintenance
  • Engineering Application Compatibility
  • Stable and reliable operation
  • Easy system integration

Model

NR2

Main Product Parameters

CategorySwitchgearSecondary CategoryMotor protection circuit breaker
ParametersCurrent frame: 13/25/36/93/150/200/630; Rated current range: 0.1~630A; Installation method: Modular, IndependentAdvantages/Core Features01 Three-phase bimetallic type, with phase failure protection, with operating mechanism, with test mechanism

Product details

Function and Purpose

The NR2 series thermal overload relay (hereinafter referred to as the thermal relay) is suitable for AC motors with a frequency of 50Hz/60Hz, voltage up to 690V, and current (0.1-150)A for long-term or intermittent long-term operation, providing overload and phase failure protection.

Detailed Description

Parameters:
Current frame size: 13/25/36/93/150/200/630
Set current range: 0.1~630A
Installation method: Combined type, independent type

Advantages/Core Functions:
01 Three-phase bimetallic type, with phase failure protection, has an actuating mechanism, and has a test mechanism

Details

Parameter CategoryParameter ItemParameter Value
Current RatingNR2-11.513
NR2-2525
NR2-3636
NR2-9393
NR2-150150
Rated Insulation Voltage VNR2-11.5690
NR2-25690
NR2-36690
NR2-93690
NR2-150690
Rated Impulse Withstand Voltage VNR2-11.56000
NR2-256000
NR2-366000
NR2-936000
NR2-1506000
Enclosure Protection LevelNR2-11.5IP20(front side)
NR2-25IP20(front side)
NR2-36IP20(front side)
NR2-93IP20(front side)
NR2-150IP00
Phase Failure ProtectionNR2-11.5Yes
NR2-25Yes
NR2-36Yes
NR2-93Yes
NR2-150Yes
Manual and Automatic ResetNR2-11.5Yes
NR2-25Yes
NR2-36Yes
NR2-93Yes
NR2-150Yes
Temperature CompensationNR2-11.5Yes
NR2-25Yes
NR2-36Yes
NR2-93Yes
NR2-150Yes
Tripping IndicationNR2-11.5Yes
NR2-25Yes
NR2-36Yes
NR2-93Yes
NR2-150Yes
Test ButtonNR2-11.5Yes
NR2-25Yes
NR2-36Yes
NR2-93Yes
NR2-150Yes
Stop ButtonNR2-11.5Yes
NR2-25Yes
NR2-36Yes
NR2-93Yes
NR2-150Yes
Installation MethodNR2-11.5Insertion Type
NR2-25Insertion Type
NR2-36Insertion Type
NR2-93Insertion Type
NR2-150Insertion Type
Auxiliary ContactNR2-11.51NO+NC
NR2-251NO+NC
NR2-361NO+NC
NR2-931NO+NC
NR2-1501NO+NC
AC-15 220V Rated Current ANR2-11.52.73
NR2-252.73
NR2-362.73
NR2-932.73
NR2-1502.73
AC-15 380V Rated Current ANR2-11.51.58
NR2-251.58
NR2-361.58
NR2-931.58
NR2-1501.58
DC-12 220V Rated Current ANR2-11.50.2
NR2-250.2
NR2-360.2
NR2-930.2
NR2-1500.2
Wire cross-sectional area mm²Main circuit Single core or stranded wireNR2-11.5 1-4
NR2-251-4
NR2-364-10
NR2-934-35
NR2-15025-50
Auxiliary circuit Single core or stranded wireNR2-11.5 1-2.5
NR2-251-2.5
NR2-361-2.5
NR2-931-2.5
NR2-1501-2.5
Wire terminal screwNR2-11.5 M3.5
NR2-25M4
NR2-36M10
NR2-93M6/M8
NR2-150M3.5

Requirement confirmation

Application, rating, quantity and drawings are checked first.

Factory matching

Supplier capacity, certificates and production slot are reviewed.

Order transaction

Confirm commercial terms, sign the commercial contract, and confirm the related document checklist.

Shipment control

Packing photos, inspection records and delivery status are tracked.