NQ2 Series Electromagnetic Starter

Product category:
soft starter
Product code:
P-421
Model:
NQ2

Function & Use (Application Scenarios)

Motor control and protection electrical appliances, motor starter products are mainly applicable to (hereinafter referred to as the starter), mainly applicable to AC 50Hz (or 60Hz), rated working voltage up to 690V, in AC-3, 380/400V usage category, rated control power up to 15kW(

Surprise on inquiry

Product highlights

  • Overload protection reliable
  • Easy installation and maintenance
  • Control response is stable
  • Engineering Application Compatibility
  • Stable and reliable operation

Model

NQ2

Main Product Parameters

CategoryInverters and Soft StartersSecondary CategorySoft starter
ParametersRated operating current: 12/18/25/32A; coil control voltage: 36/110/220/380V; coil pickup voltage: 85%~110%UsAdvantages/Core Features01 Adopting a metal enclosure protective structure, which can reach IP40 protection level; 02 Convenient installation and maintenance of the product

Product details

Function and Application

The NQ2 series electromagnetic starter (hereinafter referred to as the starter) is mainly applicable to AC 50Hz (or 60Hz), with a rated operating voltage up to 690V, under the AC-3, 380/400V application category, with a rated control power up to 15kW (current up to 32A) circuits, used to control the direct start, stop and forward and reverse operation of the motor. The starter with thermal overload relay can protect the motor against overload or phase failure. This starter is an ideal product for use with air compressors and other equipment. Standards: GB/T 14048.4, IEC/EN 60947-4-1.

Detail Description

Parameters:
Rated Operating Current: 12/18/25/32A
Coil Control Voltage: 36/110/220/380V
Coil Pickup Voltage: 85%~110%Us

Advantages/Core Functions:
01 Adopting a metal housing protective structure, achieving IP40 protection level
02 Convenient installation and maintenance of the product

Detailed Parameters

Parameter CategoryParameter ItemParameter Value
Product ModelNQ2-15□/1Model of AC contactor installed: NC1+12
Model of thermal relay installed: NR2-25
Current Setting Range: 0.1-0.16, 0.16-0.25, 0.25-0.4, 0.4-0.63, 0.63-1, 1-1.6, 1.25-2, 1.6-2.5, 2.5-4, 4-6, 5.5-8, 7-10, 9-13, 12-3
AC-3 220/230V: 0.16(0.03), 0.25(0.04), 0.4(0.06), 0.63(0.09), 1(0.18), 1.6(0.25), 2(0.37), 2.5(0.37), 4(0.75), 6(1.1), 8(1.5), 10(2.2), 12(3)
380/400V: 0.16(0.04), 0.25(0.04), 0.4(0.4), 0.63(0.63), 1(1), 1.6(1.6), 2(2), 2.5(2.5), 4(4), 6(6), 8(8), 10(10), 12(12)
660/690V: 0.16(0.06), 0.25(0.12), 0.4(0.18), 0.63(0.25), 1(0.55), 1.6(1.1), 2(1.1), 2.5(1.5), 4(3), 6(4), 8(5.5), 10(7.5), 12(11)
Model of SPCD used: gG2, gG2, gG2, gG2, gG4, gG4, gG6, gG6, gG10, gG16, gG20, gG20, gG25
Pickup Power (VA): ≤70
Holding Power: ≤9
Button Model of Starter with Button: NP2-EA31 (Start), NP2-EAA2 (Stop)
Product ModelNQ2-15□/2Model of AC Contactor Installed: NC1+18
Model of Thermal Relay Installed: NR2-25
Current Setting Range: 7-10, 9-13, 12-18, 18-25, 25-32, 32-36
AC-3 220/230V: 10(2.2), 13(3), 18(4), 25(5.5), 32(7.5)
380/400V: 10(4), 13(5.5), 18(7.5), 25(11), 32(15)
660/690V: 10(7.5), 12(10), 18(15), 25(18), 32(15)
Model of SPCD Used: gG20, gG25, gG35, gG50, gG63, gG80
Pickup Power (VA): ≤70
Holding Power: ≤9.5
Product ModelNQ2-15□/3Model of AC Contactor Installed: NC1+25
Model of Thermal Relay Installed: NR2-25
Current Setting Range: 9-13, 12-18, 17-25, 18-25, 25-32, 32-36
AC-3 220/230V: 13(3), 18(4), 25(5.5), 32(7.5)
380/400V: 13(5.5), 18(7.5), 25(11), 32(15)
660/690V: 13(11), 18(15), 25(18), 32(15)
Model of SPCD Used: gG25, gG35, gG50, gG63, gG80
Pickup Power (VA): ≤110
Holding Power: ≤14
Product ModelNQ2-15□/4Model of AC Contactor Installed: NC1+32
Model of Thermal Relay Installed: NR2-36
Current Setting Range: 23-32, 28-36
AC-3 220/230V: 23(7.5), 28(7.5)
380/400V: 23(15), 28(15)
660/690V: -
Model of SPCD Used: gG63, gG80
Pickup Power (VA): ≤110
Holding Power: ≤14

Requirement confirmation

Application, rating, quantity and drawings are checked first.

Factory matching

Supplier capacity, certificates and production slot are reviewed.

Order transaction

Confirm commercial terms, sign the commercial contract, and confirm the related document checklist.

Shipment control

Packing photos, inspection records and delivery status are tracked.