Electrical control and protection devices for motors, contactor-type relays are mainly applicable to (hereinafter referred to as relays) which are mainly used in AC 50Hz (can be used for 60Hz after derivation), with a rated operating voltage up to 380V or DC rated operating voltage up to 220V in control circuits, to control various electromagnets

Surprise on inquiry

Product highlights

  • Control response is stable
  • Engineering Application Compatibility
  • Stable and reliable operation
  • Easy system integration

Model

JZ7

Main Product Parameters

CategoryRelay Protection and Automation DevicesSecondary CategoryContactor relay
ParametersNumber of contacts: 4 sets

Product details

Function and Purpose

The JZ7 series intermediate relay (hereinafter referred to as the relay) is mainly used in control circuits with an AC frequency of 50Hz (can be used for 60Hz after derivation) and a rated operating voltage up to 380V or DC rated operating voltage up to 220V, to control various electromagnetic coils, thereby amplifying signals or transmitting signals simultaneously to relevant control components.

Detailed Description

Parameters:
Number of contacts: 4 sets

Detail Parameters

Parameter CategoryParameter ItemParameter Value
4.1 Relay Contact Configuration (see Table 1)ModelJZ7-44
Number of Normally Open Contacts4
Number of Normally Closed Contacts4
ModelJZ7-53
Number of Normally Open Contacts5
Number of Normally Closed Contacts3
ModelJZ7-62
Number of Normally Open Contacts6
Number of Normally Closed Contacts2
ModelJZ7-71
Number of Normally Open Contacts7
Number of Normally Closed Contacts1
ModelJZ7-80
Number of Normally Open Contacts8
Number of Normally Closed Contacts0
4.2 The rated control power supply voltage Us of the coil is: AC (50Hz):Rated Operating Voltage (V)12V, 24V, 36V, 48V, 110V, 127V, 220V, 240V, 380V
4.3 Operating Range:Pick-up Voltage(85%~110%)Us
Drop-out Voltage(20%~75%)Us
4.4 Main Parameters and Technical Performance Indicators of the Relay (see Table 2)Usage CategoryAC-15
Agreed Free Air Heating Current (A)380
Rated Operating Voltage (V)0.47
Rated Operating Current (A)180 VA
Control Capacity1200
Coil Power (VA)50
Operation Frequency (h^-1)300
Electrical Life Cycle ×10^41200
Mechanical Life Cycle ×10^450
Usage CategoryDC-13
Agreed Free Air Heating Current (A)5
Rated Operating Voltage (V)220
Rated Operating Current (A)0.15
Control Capacity33 W
Coil Power (VA)≤ 75
Operation Frequency (h^-1)≤ 13
Electrical Life Cycle ×10^41200
Mechanical Life Cycle ×10^450

Requirement confirmation

Application, rating, quantity and drawings are checked first.

Factory matching

Supplier capacity, certificates and production slot are reviewed.

Order transaction

Confirm commercial terms, sign the commercial contract, and confirm the related document checklist.

Shipment control

Packing photos, inspection records and delivery status are tracked.