JZC1 Series Contactor Relay

Product category:
Contactor Relay
Product code:
P-432
Model:
JZC1

Function & Use (Application Scenarios)

Electrical control and protection devices, contactor-type relay products are mainly suitable for AC 50Hz, rated operating voltage up to 660V control circuits, used to control various magnetic coil and as signal amplification and transmission, is an essential low-voltage electrical component for automation and remote control.

Surprise on inquiry

Product highlights

  • Control response is stable
  • Engineering Application Compatibility
  • Stable and reliable operation
  • Easy system integration

Model

JZC1

Main Product Parameters

CategoryRelay Protection and Automation DevicesSecondary CategoryContactor relay
ParametersContact quantity: 4 sets

Product details

Function and Usage

The JZC1 series contactor-type relay is mainly used in AC control circuits with a frequency of 50Hz and a rated operating voltage up to 660V, to control various electromagnet coils and as signal amplification and transmission, making it an essential low-voltage electrical component for automation and remote control. It complies with the standards: GB/T 14048.5, IEC60947-5-1.

Detailed Description

Parameters:
Number of contacts: 4 sets

Detailed Parameters

Parameter CategoryParameter ItemParameter Value
4.1 Main ParametersRated Operating Current (A)AC-15
220V: 10, 380V: 5, 660V: 3
Rated Insulation Voltage (V)660
Rated Impulse Withstand Voltage (kV)6
Rated Limiting Short Circuit Current (kA)10
Mechanical Life (ten thousand times)1000
Electrical Life (AC-15, ten thousand times)100
Operating Frequency (h⁻¹)AC-3: 1200, AC-15: 1200
Coil Power ConsumptionAC VA: AC-3: 10, AC-15: 10; DC W: AC-3: 68, AC-15: 15
Agreed Free Air Heating Current (A)AC-3: 10, AC-15: 15
Start: 15, Engage: 10
4.2 Rated Coil Control Supply Voltage (Us)AC380V, 220V, 127V, 110V, 48V, 36V, 24V; DC12V, 24V, 36V, 42V, 48V, 110V, 220V
4.3 The AC operation of the relay uses a direct-acting E-core, while the DC operation uses a three-air-gap permanent magnet electromagnetic system, with a direct-acting linked structure of dual-break bridge contacts, ensuring reliable operation;
4.4 Contact Combination FormModelJZC1-04, JZC1-04/Z
StructureSingle-layer
Number of Normally Open Contacts0
Number of Normally Closed Contacts4
ModelJZC1-13, JZC1-13/Z
StructureSingle-layer
Number of Normally Open Contacts1
Number of Normally Closed Contacts3
ModelJZC1-22, JZC1-22/Z
StructureSingle-layer
Number of Normally Open Contacts2
Number of Normally Closed Contacts2
ModelJZC1-31, JZC1-31/Z
StructureSingle-layer
Number of Normally Open Contacts3
Number of Normally Closed Contacts1
ModelJZC1-40, JZC1-40/Z
StructureSingle-layer
Number of Normally Open Contacts4
Number of Normally Closed Contacts0
ModelJZC1-44, JZC1-44/Z
StructureDouble-layer
Number of Normally Open Contacts4
Number of Normally Closed Contacts4
ModelJZC1-53, JZC1-53/Z
StructureDouble-layer
Number of Normally Open Contacts5
Number of Normally Closed Contacts3
ModelJZC1-62, JZC1-62/Z
StructureDouble-layer
Number of Normally Open Contacts6
Number of Normally Closed Contacts2
ModelJZC1-71, JZC1-71/V
StructureeDouble-layer
Number of Normally Open Contacts7
Number of Normally Closed Contacts1
ModelJZC1-80, JZC1-80/Z
StructureDouble-layer
Number of Normally Open Contacts8
Number of Normally Closed Contacts0

Requirement confirmation

Application, rating, quantity and drawings are checked first.

Factory matching

Supplier capacity, certificates and production slot are reviewed.

Order transaction

Confirm commercial terms, sign the commercial contract, and confirm the related document checklist.

Shipment control

Packing photos, inspection records and delivery status are tracked.