HY2 Series Reverse/Forward Switch

Product category:
Forward/Reverse Switch
Product code:
P-452
Model:
HY2

Function & Use (Application Scenarios)

Control switches, reversing switches and other main command electrical products are mainly applicable to (hereinafter referred to as switches) AC 50Hz (or 60Hz), rated working voltage up to 380V, rated working current up to 20A motor circuits, used for directly connecting and disconnecting single-phase squirrel-cage induction motors.

Surprise on inquiry

Product highlights

  • Engineering Application Compatibility
  • Stable and reliable operation
  • Easy system integration

Model

HY2

Main Product Parameters

CategoryOther (Tools / Labor Protection / Machining Equipment)Secondary CategoryReversing Switch

Product details

Function and Purpose

The HY2 series reversing switch (hereinafter referred to as the switch) is mainly applicable to AC 50Hz (or 60Hz), rated working voltage up to 380V, and rated working current up to 20A motor circuits, used for directly switching on and off a single squirrel-cage induction motor, allowing it to rotate forward, reverse, and stop. It complies with the standard: GB/T 14048.3.

Detailed Parameters

Parameter CategoryParameter ItemParameter Value
Product ModelHY2-8
Rated Working Current A8
Agreed Heating Current A15
Rated Control Power (kW) AC-3380V3
220V1.8
Connection Wire Cross Section mm²1.5~4
Maximum Operating Torque N·m1.96
Product ModelHY2-12
Rated Working Current A12
Agreed Heating Current A30
Rated Control Power (kW) AC-3380V5.5
220V3
Connection Wire Cross Section mm²2.5~6
Maximum Operating Torque N·m2.94
Product ModelHY2-20
Rated Working Current A20
Agreed Heating Current A30
Rated Control Power (kW) AC-3380V10
220V5.5
Connection Wire Cross Section mm²2.5~6
Maximum Operating Torque N·m2.94
Mechanical Life10×10⁴ times
Electrical Life1.2×10⁴ times
Enclosure Protection LevelIP20
Operating Frequency120 times/h, duty cycle not exceeding 60%

Requirement confirmation

Application, rating, quantity and drawings are checked first.

Factory matching

Supplier capacity, certificates and production slot are reviewed.

Order transaction

Confirm commercial terms, sign the commercial contract, and confirm the related document checklist.

Shipment control

Packing photos, inspection records and delivery status are tracked.