Function and Usage
The YBLX-22 series limit switches are suitable for use in circuits with AC 50Hz or 60Hz, voltage 380V, and DC voltage 220V. They are used as devices to limit the travel of various lifting and transportation machinery, metallurgical plant equipment, and coal and coke equipment.
Detailed Parameters
| Parameter Category | Parameter Item | Parameter Value |
|---|
| Protection Level | | IP52 |
| Rated Heating Current | 20A |
| Rated Voltage | AC-15: 380V DC-13: 220V |
| Altitude | ≤ 2000m |
| Environmental Temperature | -5℃ ~ +40℃ |
| Relative Humidity | At a maximum temperature of +40℃, the air's relative humidity must not exceed 50%. At lower temperatures, higher relative humidity is allowed, for example, at 20℃, humidity can reach 90%. Special measures should be taken for occasional condensation caused by temperature changes. |
| Rated Working Current | AC-15: 1.35A DC-13: 0.2A |
| Installation Category | II |
| Pollution Degree | Level 3 |
| Rated Insulation Voltage | 415V |
| Rated Impulse Withstand Voltage | 2.5kV |
| Application Scope | Limiting the travel of cranes and various equipment |
| Altitude | ≤ 2000m |
| Installation Conditions | Install in places without significant vibration and impact |
| Model | YBLX-22/1 | Single-arm roller, suitable for translational mechanisms with not very large inertia travel |
| YBLX-22/2 | Double roller fork arm, suitable for translational mechanisms with larger inertia travel |