Relays, small electromagnetic relays are mainly applicable to two types of contact forms, 1Z and 2Z; AC and DC specifications are complete; high contact reliability, transparent dust-proof cover encapsulation; matching sockets are available; optional mechanical lockout and power-on indication functions; the product is certified by CQC and CE

Surprise on inquiry

Product highlights

  • Reliable protection level
  • Engineering Application Compatibility
  • Stable and reliable operation
  • Easy system integration

Model

NJX12

Main Product Parameters

CategoryRelay Protection and Automation DevicesSecondary CategoryElectromagnetic relay

Product details

Function and Usage

1Z, 2Z contact forms; complete AC and DC specifications; high contact reliability, transparent dustproof housing; available with matching sockets; optional mechanical lockout, power-on indication function; product certified by CQC, CE.

Detailed Parameters

Parameter CategoryParameter ItemParameter Value
3.1 Contact ParametersContact Form1Z(C), 2Z(C)
Contact Resistance50mΩ (DC6V, 1A)
Contact MaterialSilver Alloy
Contact Load (Resistive)1Z: 12A 250VAC/30VDC
2Z: 8A 250VAC/30VDC
Maximum Switching Voltage250VAC/30VDC
Maximum Switching Current1Z: 12A 2Z: 8A
Maximum Switching Power1Z: 3000VA/360W
2Z: 2000VA/240W
Electrical Life (Cycles)1×10⁴ Ambient Temperature: 25℃±2℃
Mechanical Life (Cycles)1X10⁷
3.2 Performance and Feature ParametersInsulation Resistance100MQ (500VDC)
Dielectric StrengthCoil to Contact: 5000VAC, 1min
Between Different Contacts: 3000VAC
Between Open Contacts: 1000VAC
Operation Time (at 25℃, rated voltage)≤ 20ms
Release Time (at 25℃, rated voltage)≤ 20ms
Shock (Stability)Acceleration 100m/s², pulse duration 11ms
VibrationDouble Amplitude 1mm, (10-55)Hz
Terminal TypePlug-in Type
Maximum Overall Dimensions (mm)29×13×30.5
3.3 Coil ParametersRated Power Consumption0.64W, 1.2VA
Pick-up VoltageDC: ≤ 75% Rated Voltage; AC: ≤ 80% Rated Voltage
Drop-out VoltageDC: ≥ 10% Rated Voltage; AC: ≥ 20% Rated Voltage
Maximum Voltage110% Rated Voltage

Requirement confirmation

Application, rating, quantity and drawings are checked first.

Factory matching

Supplier capacity, certificates and production slot are reviewed.

Order transaction

Confirm commercial terms, sign the commercial contract, and confirm the related document checklist.

Shipment control

Packing photos, inspection records and delivery status are tracked.