Function and Usage
1Z, 2Z contact forms; complete AC and DC specifications; high contact reliability, transparent dustproof housing; available with matching sockets; optional mechanical lockout, power-on indication function; product certified by CQC, CE.
Detailed Parameters
| Parameter Category | Parameter Item | Parameter Value |
|---|
| 3.1 Contact Parameters | Contact Form | 1Z(C), 2Z(C) |
| Contact Resistance | 50mΩ (DC6V, 1A) |
| Contact Material | Silver Alloy |
| Contact Load (Resistive) | 1Z: 12A 250VAC/30VDC 2Z: 8A 250VAC/30VDC |
| Maximum Switching Voltage | 250VAC/30VDC |
| Maximum Switching Current | 1Z: 12A 2Z: 8A |
| Maximum Switching Power | 1Z: 3000VA/360W 2Z: 2000VA/240W |
| Electrical Life (Cycles) | 1×10⁴ Ambient Temperature: 25℃±2℃ |
| Mechanical Life (Cycles) | 1X10⁷ |
| 3.2 Performance and Feature Parameters | Insulation Resistance | 100MQ (500VDC) |
| Dielectric Strength | Coil to Contact: 5000VAC, 1min Between Different Contacts: 3000VAC Between Open Contacts: 1000VAC |
| Operation Time (at 25℃, rated voltage) | ≤ 20ms |
| Release Time (at 25℃, rated voltage) | ≤ 20ms |
| Shock (Stability) | Acceleration 100m/s², pulse duration 11ms |
| Vibration | Double Amplitude 1mm, (10-55)Hz |
| Terminal Type | Plug-in Type |
| Maximum Overall Dimensions (mm) | 29×13×30.5 |
| 3.3 Coil Parameters | Rated Power Consumption | 0.64W, 1.2VA |
| Pick-up Voltage | DC: ≤ 75% Rated Voltage; AC: ≤ 80% Rated Voltage |
| Drop-out Voltage | DC: ≥ 10% Rated Voltage; AC: ≥ 20% Rated Voltage |
| Maximum Voltage | 110% Rated Voltage |