NJDC-12 Small Electromagnetic Relay with Test Button

Product category:
Electromagnetic Relay
Product code:
P-509
Model:

Function & Use (Application Scenarios)

Relays, small electromagnetic relays are mainly applicable to two types of contact forms, 2Z and 3Z; the contact switching current can reach 10A; AC and DC specifications are complete; they have a test button function, which can be momentary or latched. A variety of plug-in sockets are available for selection

Surprise on inquiry

Product highlights

  • Engineering Application Compatibility
  • Stable and reliable operation
  • Easy system integration

Model

Main Product Parameters

CategoryRelay Protection and Automation DevicesSecondary CategoryElectromagnetic relay

Product details

Function and Usage

Two types of contact forms, 2Z and 3Z; contact switching current can reach 10A; AC and DC specifications are complete; has a test button function, which can be toggled or locked in the closed position. A variety of plug-in sockets are available for selection.

Detailed Parameters

Parameter CategoryParameter ItemParameter Value
3.1 Contact ParametersContact FormZZ(C), 3Z(C)
Initial Contact Resistance100mΩ
Contact MaterialSilver Alloy
Contact Load (Resistive)10A/250VAC, 10A/30VDC
Maximum Switching Voltage250VAC/30VDC
Maximum Switching Current10A
Maximum Switching Power2500VA/300W
Electrical Life (Times)1×10^5
Mechanical Life (Times)1×10^7
3.2 Performance and Characteristics ParametersInsulation Resistance100MΩ (500VDC)
Dielectric StrengthCoil Winding, between different contact groups 1500VAC
Open Contact500VAC
Operation Time (at 25℃, rated voltage)≤20ms
Release Time (at 25℃, rated voltage)≤20ms
Shock (Stability)Acceleration 100m/s², pulse duration 11ms
VibrationDouble Amplitude 1mm, (10-55)Hz
Terminal FormPlug-in Type
Maximum Overall Dimensions (mm)35×35×67.4
3.3 Coil ParametersRated PowerDC: Approximately 1.6W, AC: Approximately 3VA
Pick-up VoltageDC: ≤80% Rated Voltage; AC: ≤80% Rated Voltage
Drop-out VoltageDC: ≥10% Rated Voltage; AC: ≥20% Rated Voltage
Maximum Voltage110% Rated Voltage
3.4 Specification ParametersRated Voltage VDCPick-up Voltage VDC (≤) Drop-out Voltage VDC (≥) Coil Resistance Ω
64.8 0.6 22Ω(±10%)
129.6 1.2 80Ω(±10%)
2419.2 2.4 360Ω(±10%)
3628.8 3.6 840Ω(±10%)
4838.4 4.8 1440Ω(±15%)
11088.0 11.0 7560Ω(±15%)
220176.0 22.0 29000Ω(±15%)
230184 46 7950Ω(±15%)
240192 48 8600Ω(±15%)
380304.0 76 21000Ω(±15%)

Requirement confirmation

Application, rating, quantity and drawings are checked first.

Factory matching

Supplier capacity, certificates and production slot are reviewed.

Order transaction

Confirm commercial terms, sign the commercial contract, and confirm the related document checklist.

Shipment control

Packing photos, inspection records and delivery status are tracked.