JD-5E Motor Protector

Product category:
Protection Relay
Product code:
P-523
Model:

Function & Use (Application Scenarios)

Relays, protective relays are mainly applicable for AC 50Hz, rated insulation voltage AC690V or below, and rated operating current 1A~400A for long-term or intermittent operation of AC motors for overload and phase failure protection. The protector is generally used with AC

Surprise on inquiry

Product highlights

  • Overload protection is reliable
  • Engineering Application Compatibility
  • Stable and reliable operation
  • Easy system integration

Model

Main Product Parameters

CategoryRelay Protection and Automation DevicesSecondary CategoryProtection Relay

Product details

Function and Application

The JD-5E Motor Protector is suitable for AC motors with an insulation voltage of AC690V or less, a rated operating current of 1A to 400A, and long-term or intermittent operation. The protector is generally used in conjunction with an AC contactor. It complies with the standards: GB/T 14048.4 and IEC 60947-4-1.

Detailed Parameters

Parameter CategoryParameter ItemParameter Value
4.1 Main Circuit: Rated Insulation Voltage AC690V, Rated Frequency 50Hz (see Table 1).ModelJD-5E
Set Current Range (A)1-5
Rated Control Circuit Supply Voltage (V)AC220V, AC380V, 50Hz
Allowable Fluctuation Range of Rated Control Circuit Supply Voltage85%-110%
Motor Power Suitable (kW)0.5-2.5
ModelJD-5E
Set Current Range (A)5-25
Rated Control Circuit Supply Voltage (V)AC220V, AC380V, 50Hz
Allowable Fluctuation Range of Rated Control Circuit Supply Voltage85%-110%
Motor Power Suitable (kW)2.5-12.5
ModelJD-5E
Set Current Range (A)20-80
Rated Control Circuit Supply Voltage (V)AC220V, AC380V, 50Hz
Allowable Fluctuation Range of Rated Control Circuit Supply Voltage85%-110%
Motor Power Suitable (kW)10-40
ModelJD-5E
Set Current Range (A)80-200
Rated Control Circuit Supply Voltage (V)AC220V, AC380V, 50Hz
Allowable Fluctuation Range of Rated Control Circuit Supply Voltage85%-110%
Motor Power Suitable (kW)40-100
ModelJD-5E
Set Current Range (A)160-400
Rated Control Circuit Supply Voltage (V)AC220V, AC380V, 50Hz
Allowable Fluctuation Range of Rated Control Circuit Supply Voltage85%-110%
Motor Power Suitable (kW)80-200
4.2 Control Circuit: Rated Insulation Voltage AC415V, Rated Frequency 50Hz, Contact Parameters See Table 2.Usage CategoryAC-15
Rated Operating Voltage (V)240
Rated Operating Current (A)1.5
Rated Heating Current (A)5
Contact Parameters415
Contact Parameters0.95

Requirement confirmation

Application, rating, quantity and drawings are checked first.

Factory matching

Supplier capacity, certificates and production slot are reviewed.

Order transaction

Confirm commercial terms, sign the commercial contract, and confirm the related document checklist.

Shipment control

Packing photos, inspection records and delivery status are tracked.