| 3 Main Parameters and Technical Performance | Model | NJS1, NJS1-2Z, NJS1-11, NJS1-K, NJS1-S |
| Operating Mode | Power-on Time, Power-on Time, Power-on Time, Power-on Time, Cycle Delay |
| Number of Contacts | Instantaneous 1 Changeover, Instantaneous 2 Changeover, Instantaneous 2 Changeover, Instantaneous 1 Changeover, Instantaneous 1 Changeover |
| Contact Capacity | Ue: AC-15 240V/0.75A, 415V/0.47A; DC-13 220V/0.27A; Ith: 5A |
| Power-on Time Timer | Time Base Code: 0.01s, 0.1s, 10s, m, h; Setting Range: 0.01s-99.99s, 0.1s-99.99s, 10s-9999s, 1s-99min, 1min-99h, 1h-99h |
| Cycle Delay Timer | Time Base Code: 0.1s, 1s, 10s, 0.1min, 1min, 0.1h; Setting Range: 0.1s-9.9s, 1s-99s, 10s-990s, 1min-9.9min, 1min-99min, 0.1h-9.9h |
| Rated Control Voltage Allowable Fluctuation Range | AC/DC24V-48V, AC/DC100-240V, AC220V, AC380V, 50Hz; 85%-110% |
| Unit Stop and Restart Function | No, Yes, No, Yes, Yes |
| Power Supply | 1×10^6 |
| Mechanical Life | No, 1×10^6, No, 1×10^6, 1×10^6 |
| Environmental Temperature | -5℃~+40℃ |
| Power Consumption | ≤3VA |
| Installation Method | Panel Mounting, Cabinet Mounting, Cabinet Mounting, Cabinet Mounting, Cabinet Mounting |
| Base Compatibility | Standard CZ5085 CZ5115 Cabinet Mounting or Complete Set; CZ508C CZF11A-E |
| | NJS1-H, NJS1-M |
| Number of Contacts | Instantaneous 1 Changeover |
| Contact Capacity | Ue: AC-15 240V/0.75A, AC415V/0.47A; DC-13 220V/0.27A; Ith: 5A |
| Output Contact Capacity | Maximum 30VDC Maximum 100mA; DC24V |
| Rated Control Voltage Allowable Fluctuation Range | AC/DC24V-240V, 50Hz; AC/DC100-240V, 50Hz |
| Power Supply | 1×10^6 |
| Mechanical Life | 1×10^6 |
| Short-time Accuracy | When the relay is set to start timing upon power-on, the setting relative error should not exceed ±0.01% + tset × 50ms (when the time unit is not seconds, it should be converted into seconds for calculation); When the relay is set to start timing upon connection signal, the setting relative error should not exceed ±0.01% + tset × 130ms (when the time unit is not seconds, it should be converted into seconds for calculation) |
| Timing | Optional Up and Down Timing Function |
| Contact Output Time | Output contact automatically resets, output contact time 10, 50, 100, 200, 500, 1000, 2000, 5000, Hold. (Unit: ms) |
| Environmental Temperature | -40℃~+40℃ |
| Installation Method | Panel Mounting |
| Time Range | Units can choose 99.99/999.99/9999.99/99999.99/999999.99/9999999.99 |