NJYW1 Series Level Relay

Product category:
Impulse Relay
Product code:
P-562
Model:
NJYW1

Function & Use (Application Scenarios)

Relay and pulse relay products are mainly applicable to AC 50Hz, with a rated control circuit power supply voltage up to 380V control circuits for use in liquid level automatic control in places such as domestic water towers, high-level water tanks, underground reservoirs. They can be connected according to the user's wiring requirements to achieve self

Surprise on inquiry

Product highlights

  • Control response is stable
  • Engineering Application Compatibility
  • Stable and reliable operation
  • Easy system integration

Model

NJYW1

Main Product Parameters

CategoryRelay Protection and Automation DevicesSecondary categoryPulse Relay

Product details

Function and Application

The NJYW1 series liquid level relay is applicable to AC 50Hz, the control circuit with rated control circuit power supply voltage up to 380V, for automatic liquid level control in civil water towers, high-level water tanks, underground reservoirs, etc. It can realize automatic water supply or drainage control according to the user's wiring requirements. This product is not suitable for liquid level control of liquids with very poor conductivity such as oil, purified water, flammable and explosive chemical liquids, and high-density sewage.

Detailed Parameters

Parameter ClassificationParameter ItemParameter Value
3 Main Parameters and Technical PerformanceModelNJYW1-NL1
NJYW1-NL2
NJYW1-BL1
NJYW1-BL2
Working ModeContinuous Operation
Number of Contacts1 set of transfer contacts
1 set normally open, 1 set normally closed
Contact CapacityUe/le: AC-15 240V/0.75A, 415V/0.47A; Ith 5A
Rated Control Circuit Power Supply VoltageAC 36V, AC 110V/220V, AC 220V/380V, 50Hz
AC 36V, AC 110V, AC 220V, AC 380V, 50Hz
Allowable Fluctuation Range of Rated Control Circuit Power Supply Voltage85%-110%
Control Electrode VoltageAC 24V
Wire LengthMaximum 1km
Maximum 2km
Maximum 1km
Maximum 2km
Action Resistance≤25kΩ
Release Resistance≥2kΩ
Response TimeAction: Maximum 80ms; Release: Maximum 160ms
Environmental Temperature-5℃~+40℃
Power Consumption<3VA
Installation MethodRail mounting or panel mounting

Requirement confirmation

Application, rating, quantity and drawings are checked first.

Factory matching

Supplier capacity, certificates and production slot are reviewed.

Order transaction

Confirm commercial terms, sign the commercial contract, and confirm the related document checklist.

Shipment control

Packing photos, inspection records and delivery status are tracked.