Function and Usage
The contact switching current can reach 16A, 32A; AC and DC specifications are complete; it meets the requirements of GB/T 21711.1 standard; the NJMC1 pulse relay is a mechanical bistable relay that changes the contact state by inputting a pulse signal. Therefore, compared to ordinary relays that require continuous power supply when the armature closes, the pulse relay has the characteristic of low power consumption.
Detailed Parameters
| Parameter Category | Parameter Item | Parameter Value |
|---|
| 4.1 Contact Parameters | Contact Type | 1P, 2P, 3P, 4P |
| Initial Contact Resistance | 100mΩ |
| Contact Material | Silver Alloy |
| Contact Load (Resistive) | NJMC1-16: 16A 250VAC NJMC1-32: 32A 250VAC |
| Maximum Switching Voltage | 250VAC |
| Maximum Switching Current | NJMC1-16: 16A NJMC1-32: 32A |
| Maximum Switching Power | NJMC1-16: 4000VA NJMC1-32: 8000VA |
| Electrical Life (Times) | NJMC1-16: 1×10⁵ NJMC1-32: 5×10⁵ |
| Mechanical Life (Times) | NJMC1-16: 2×10⁵ NJMC1-32: 1×10⁶ |
| 4.2 Performance and Characteristic Parameters | Insulation Resistance | 100MΩ (500VDC) |
| Dielectric Withstand Voltage | Between contacts and coil: 4000VAC Between open contacts: 1500VAC |
| Operating Time (at 25°C, rated voltage) | ≤20ms |
| Operating Frequency | ≤5 times/min |
| Shock (Stability) | Acceleration 100m/s², pulse duration 11ms |
| Vibration | Double amplitude 1mm, (10-55)Hz |
| Installation Method | Rail-mounted |
| Dimensions (mm) | 86×70×18 |
| 4.3 Coil Parameters | Pulse Voltage Duration | 50ms ≤t<1s (recommended 200ms) |
| Voltage Range | 85%-110% |