JZF Series Forward and Reverse Control Relay

Product category:
Forward/Reverse Control Relay
Product code:
P-566
Model:

Function & Use (Application Scenarios)

Relays, forward and reverse control relays are mainly used in AC frequency 50Hz, with a rated control power supply voltage up to 380V control circuits as time control elements, to connect or disconnect the circuit according to a predetermined time

Surprise on inquiry

Product highlights

  • Control response is stable
  • Engineering Application Compatibility
  • Stable and reliable operation
  • Easy system integration

Model

Main Product Parameters

CategoryRelay Protection and Automation DevicesSecondary categoryForward and Reverse Control Relay

Product details

Function and Use

JZF series reversible control relays are mainly used in control circuits with an AC frequency of 50Hz and a rated control power supply voltage up to 380V as a time control element, connecting or disconnecting the circuit according to a predetermined time.

Detailed Parameters

Parameter CategoryParameter ItemParameter Value
ModelJZF-01
Control TimeForward (Reverse): 25s
Stop: 5s
Rated Control Circuit Power Supply VoltageAC220V, AC380V, 50Hz
Allowable Fluctuation Range of Rated Control Circuit Power Supply Voltage85%~110%
Contact Number2 Normally Open Transfer
Contact CapacityUe/le: AC-15 220V/0.75A, 380V/0.47A; lth: 3A
Electrical Life1x10⁵
Mechanical Life1x10⁶
Installation MethodUnit Type
Control MethodRepeated Cycle
Environmental Temperature-5℃~+40℃
ModelJZF-05
Control TimeForward (Reverse): 15s
Stop: 5s Drying: 5s
Rated Control Circuit Power Supply VoltageAC220V, AC380V, 50Hz
Allowable Fluctuation Range of Rated Control Circuit Power Supply Voltage85%~110%
Contact Number3 Normally Open Transfer
Contact CapacityUe/le: AC-15 220V/0.75A, 380V/0.47A; lth: 3A
Electrical Life1x10⁵
Mechanical Life1x10⁶
Installation MethodUnit Type
Control MethodRepeated Cycle
Environmental Temperature-5℃~+40℃
ModelJZF-06
Control TimeForward (Reverse): (1, 2, 4, 8, 16)min
Stop: (0.5, 1, 2, 4)s
Rated Control Circuit Power Supply VoltageAC220V, AC380V, 50Hz
Allowable Fluctuation Range of Rated Control Circuit Power Supply Voltage85%~110%
Contact Number2 Normally Open Transfer
Contact CapacityUe/le: AC-15 220V/0.75A, 380V/0.47A; lth: 3A
Electrical Life1x10⁵
Mechanical Life1x10⁶
Installation MethodUnit Type
Control MethodRepeated Cycle
Environmental Temperature-5℃~+40℃
ModelJZF-07
Control TimeForward (Reverse): (1, 2, 4, 8)min
Stop: (1, 2, 4, 8)s
Rated Control Circuit Power Supply VoltageAC220V, AC380V, 50Hz
Allowable Fluctuation Range of Rated Control Circuit Power Supply Voltage85%~110%
Contact Number2 Normally Open Transfer
Contact CapacityUe/le: AC-15 220V/0.75A, 380V/0.47A; lth: 3A
Electrical Life1x10⁵
Mechanical Life1x10⁶
Installation MethodUnit Type
Control MethodRepeated Cycle
Environmental Temperature-5℃~+40℃

Requirement confirmation

Application, rating, quantity and drawings are checked first.

Factory matching

Supplier capacity, certificates and production slot are reviewed.

Order transaction

Confirm commercial terms, sign the commercial contract, and confirm the related document checklist.

Shipment control

Packing photos, inspection records and delivery status are tracked.