NJG1 Series Solid State Relays

Product category:
Solid-state Relay
Product code:
P-567
Model:
NJG1

Function & Use (Application Scenarios)

Relays, solid state relays products are mainly applicable to (hereinafter referred to as relays), which use SCR structure internally, zero-crossing conduction, have built-in RC absorption circuit, and are encapsulated with epoxy resin. They are widely used in electric furnace heating temperature control systems, CNC machinery, plastic machinery, food machinery, packaging

Surprise on inquiry

Product highlights

  • Control response is stable
  • Engineering Application Compatibility
  • Stable and reliable operation
  • Easy system integration

Model

NJG1

Main Product Parameters

CategoryRelay Protection and Automation DevicesSecondary CategorySolid State Relay

Product details

Function and Application

The NJG1 series solid state relay (hereinafter referred to as the relay) uses an SCR structure internally, zero-crossing conduction, has an internal RC absorption circuit, and is filled with epoxy resin. It is widely used in electric furnace heating temperature control systems, CNC machinery, plastic machinery, food machinery, packaging machinery, textile machinery, petrochemical instruments, entertainment facilities, and other automation control fields, suitable for resistive, inductive, and capacitive loads.

Detailed Parameters

Parameter CategoryParameter ItemParameter Value
Input ParametersInput Control VoltageDC4V-32V
Turn-on Voltage≤ DC4V
Turn-off Voltage≥ DC1V
Input Control Current≤ 15mA
Reverse Polarity Voltage-DC32V
Output ParametersOutput Voltage Range240V: AC48V~280V; 380V: AC48V~440V
Output Voltage Frequency47Hz~63Hz
Blocking Voltage240V/600Vpk; 380V: 800Vpk
On-state Current10A
Overload Current15A
Maximum It Value (10ms, A²s)110
Maximum Surge Current (10ms)150Apk
Off-state Current≤ 5mA
On-state Voltage≤ AC1.7V
Turn-on TimeZero-crossing type: ≤ 1/2 cycle + 1ms
Turn-off Time≤ 1/2 cycle + 1ms
Off-state Voltage Critical Rise Rate dv/dt500V/us
Minimum Load Power Factor0.5
Other ParametersInsulation VoltageBetween input and output: ≥ AC4000V 1min; Between input/output and base plate: ≥ AC2500V 1min
Insulation Resistance1000MΩ (DC500V)
Operating IndicatorLED
Protection MethodMOV Protection

Requirement confirmation

Application, rating, quantity and drawings are checked first.

Factory matching

Supplier capacity, certificates and production slot are reviewed.

Order transaction

Confirm commercial terms, sign the commercial contract, and confirm the related document checklist.

Shipment control

Packing photos, inspection records and delivery status are tracked.