Function and Application
The NJG1 series solid state relay (hereinafter referred to as the relay) uses an SCR structure internally, zero-crossing conduction, has an internal RC absorption circuit, and is filled with epoxy resin. It is widely used in electric furnace heating temperature control systems, CNC machinery, plastic machinery, food machinery, packaging machinery, textile machinery, petrochemical instruments, entertainment facilities, and other automation control fields, suitable for resistive, inductive, and capacitive loads.
Detailed Parameters
| Parameter Category | Parameter Item | Parameter Value |
|---|
| Input Parameters | Input Control Voltage | DC4V-32V |
| Turn-on Voltage | ≤ DC4V |
| Turn-off Voltage | ≥ DC1V |
| Input Control Current | ≤ 15mA |
| Reverse Polarity Voltage | -DC32V |
| Output Parameters | Output Voltage Range | 240V: AC48V~280V; 380V: AC48V~440V |
| Output Voltage Frequency | 47Hz~63Hz |
| Blocking Voltage | 240V/600Vpk; 380V: 800Vpk |
| On-state Current | 10A |
| Overload Current | 15A |
| Maximum It Value (10ms, A²s) | 110 |
| Maximum Surge Current (10ms) | 150Apk |
| Off-state Current | ≤ 5mA |
| On-state Voltage | ≤ AC1.7V |
| Turn-on Time | Zero-crossing type: ≤ 1/2 cycle + 1ms |
| Turn-off Time | ≤ 1/2 cycle + 1ms |
| Off-state Voltage Critical Rise Rate dv/dt | 500V/us |
| Minimum Load Power Factor | 0.5 |
| Other Parameters | Insulation Voltage | Between input and output: ≥ AC4000V 1min; Between input/output and base plate: ≥ AC2500V 1min |
| Insulation Resistance | 1000MΩ (DC500V) |
| Operating Indicator | LED |
| Protection Method | MOV Protection |