Function and Use
Plastic housing is safe
Detailed Description
Parameters:
Input Voltage Range (V): 85V~264V
Output Voltage (V): 5, 12, 15, 24, 48
Output Ripple and Noise: 5V ≤ 80mV; 12V, 15V ≤ 120mV; 24V ≤ 200mV; 48V ≤ 240mV
Output Voltage Stability: 5V, 12V: ±2%; 15V, 24V, 48V: ±1%
Load Stability: 12V: ±1%; 24V, 36V, 48V: ±0.5%
Electromagnetic Interference: Class A (Industrial Grade)
Advantages/Core Features:
01 Safe and Reliable
Comprehensive protection functions including overload, overvoltage, overtemperature, and short circuit, making the usage safer
Plastic casing with heat dissipation holes design ensures safety while also considering heat dissipation
Coil winding vacuum impregnation insulation treatment, higher insulation strength and mechanical strength
02 Excellent Performance
Efficiency greater than 83%
Full range voltage input 85V~264VAC
Soft start and PWM control circuit design effectively reduce the impact on the power grid
-30℃~+70℃ extreme operating temperature, no derating at low temperatures, easily adaptable to various environments
03 Flexible Application
LED indicator for power-on, product working status is clearly visible
Stepped shape design, modular size, thin and lightweight, saving space
Detail Parameters
| Parameter Category | Parameter Item | Parameter Value |
|---|
| Model | NKY6-15 |
| | NKY6-30 |
| | NKY6-60 |
| | NKY6-100 |
| Output | DC Output Voltage | 5V |
| | 12V |
| | 15V |
| | 24V |
| | 48V |
| Output Power | 12W |
| | 15W |
| | 15W |
| | 15W |
| | 15W |
| | 24W |
| | 30W |
| | 36W |
| | 32.5W |
| | 54W |
| | 60W |
| | 60W |
| | 90W |
| | 97.5W |
| | 100W |
| | 100W |
| Output Ripple and Noise | ≤80mV |
| | ≤120mV |
| | ≤150mV |
| | ≤240mV |
| | ≤80mV |
| | ≤120mV |
| | ≤150mV |
| | ≤240mV |
| | ≤80mV |
| | ≤120mV |
| | ≤150mV |
| | ≤240mV |
| Output Voltage Stability | ±2% |
| | ±1% |
| | ±2% |
| | ±1% |
| Load Stability | ±2% |
| | ±1% |
| | ±2% |
| | ±1% |
| | ±2% |
| | ±1% |
| Voltage Adjustment Range | ±10% |
| Hold Time | ≥12ms |
| Input | Input Voltage Range | 85V-264V |
| Frequency Range | 47Hz-63Hz |
| Efficiency | ≥84% |
| | ≥85% |
| | ≥86% |
| | ≥89% |
| | ≥83% |
| | ≥85% |
| | ≥86% |
| | ≥89% |
| | ≥87% |
| | ≥89% |
| | ≥90% |
| | ≥88% |
| Input AC Current | 0.5A/110VAC 0.25A/220VAC |
| | 0.88A/110VAC 0.48A/220VAC |
| | 1.8A/110VAC 0.8A/220VAC |
| | 3A/110VAC 1.6A/220VAC |
| Input Surge Current | ≤37.5A |
| | ≤57.2A |
| | ≤117A |
| | ≤150A |
| Protection | Overload Protection | 105%-150% Mode: Auto-recover after abnormality |
| Overvoltage Protection | 105%-150% Mode: Output shutdown, restart recovery |
| Short Circuit Protection | Mode: Auto-recover after abnormality |
| Overtemperature Protection | / |
| | 95℃ Protection Mode: Abnormality elimination, output voltage off, restart recovery |
| Environment | Pollution Degree | 2 |
| Overvoltage Level | II Level |
| Safety Standards and Electromagnetic Compatibility | Dielectric Strength | Input and output terminals: 3kVAC |
| Electromagnetic compatibility emission | Class A |