Function and Usage
Efficiency higher than 90%
Details
Parameters:
Input Voltage Range (V): 90V~264V
Output Voltage (V): 12, 24, 48
Output Ripple and Noise: 12V, 24V ≤ 120mV; 48V ≤ 200mV
Voltage Adjustment Range: ±10%
Electromagnetic Interference: Class A (Industrial Grade)
Advantages/Core Features:
01 Safe and Reliable
Comprehensive protection functions including overload, overvoltage, overtemperature, and short circuit, making the usage safer
Coil winding vacuum impregnated insulation treatment, providing higher insulation strength and mechanical strength
02 Excellent Performance
Efficiency greater than 90%
Can reach up to 2 times overload, with a large protection range and strong load capacity
Soft start and PWM control circuit design effectively reduce the impact on the power grid
-30℃~+70℃ extreme operating temperature, easily cope with various environments
03 Flexible Application
LED indicator for power-on, making the product's working status clearly visible
Width reduced by 20%~44%, slim and portable, saving space
Detail Parameters
| Parameter Category | Parameter Item | Parameter Value |
|---|
| Output | DC Output Voltage | 12V, 24V, 48V |
| Output Power | 120W, 150W, 240W, 480W |
| Output Ripple and Noise | ≤120mV, ≤200mV |
| Output Voltage Stability | ±2%, ±1% |
| Load Stability | ±1% |
| Voltage Adjustment Range | ±10% |
| Hold-up Time | ≥12ms |
| Input | Input Voltage Range | 90V-264V |
| Frequency Range | 47Hz-63Hz |
| Efficiency | ≥91%, ≥93%, ≥92%, ≥93%, ≥94% |
| Input AC Current | 1.5A/110VAC 0.75A/220VAC, 2A/110VAC 1A/220VAC, 3A/110VAC 1.5A/220VAC, 5.5A/110VAC 2.5A/220VAC |
| Input Surge Current | ≤45A, ≤60A, ≤90A, ≤110A |
| Protection | Overload Protection | 105%-200% Mode: Self-recoverable after anomaly elimination; 105%-150% Mode: Self-recoverable after anomaly elimination |
| Overvoltage Protection | 105%-150% Mode: Output shutdown, restart recovery |
| Short Circuit Protection | Mode: Self-recoverable after anomaly elimination |
| Overtemperature Protection | 95℃ Protection Mode: Self-recoverable after anomaly elimination |
| Environment | Pollution Degree | 2 |
| Overvoltage Category | II |
| Safety Standards and Electromagnetic Compatibility | Dielectric Strength | Between input terminal and output terminal: 3kVAC; Between input terminal and ground terminal: 1.5kVAC; Between output terminal and ground terminal: 0.5kVAC |
| Electromagnetic Compatibility Emission | Class A |
| Parameter Category | Parameter Item | Parameter Value |
| Output Power and Ambient Temperature Relationship | Ambient Temperature (°C) | -30, -25, 0, 20, 40, 50, 60, 70 |
| Output Power (%) | 100%, 100%, 100%, 100%, 100%, 100%, 100%, 100% |
| Parameter Category | Parameter Item | Parameter Value |
| Output Power and Input Voltage Relationship | Input Voltage (V) | 90, 100, 120, 140, 160, 180, 200, 220, 240, 264 |
| Output Power (%) | 100%, 100%, 100%, 100%, 100%, 100%, 100%, 100%, 100%, 100% |