Function and Application
NXKY series switch power supplies are suitable for industrial automation control systems, communication and monitoring systems, instrument devices and artificial intelligence systems, semiconductor manufacturing equipment, LED display screens, machinery and electrical equipment, as control power supply, lighting power supply, and signal power supply for equipment. Complies with the standard: Q/ZT 305. Certification: CE.
Detail Description
Parameters:
Input Voltage Range (V): 85V~264V
Output Voltage (V): 12, 24, 36, 48
Output Ripple and Noise: 12V≤150mV; 24V, 36V, 48V≤200mV
Output Voltage Stability: 12V: ±1.5%; 24V, 36V, 48V: ±1%
Load Stability: 12V: ±1%; 24V, 36V, 48V: ±0.5%
Electromagnetic Interference: Class A (Industrial Grade)
Advantages/Core Functions:
01 Safe and Reliable
Comprehensive protection functions including overload, overvoltage, overtemperature, and short circuit, making the usage process safer
Metal housing with a novel cube-shaped heat dissipation hole design, which simultaneously ensures heat dissipation effect
Coil winding vacuum impregnation insulation treatment, providing higher insulation strength and mechanical strength
02 Excellent Performance
Efficiency up to 90%
Full range voltage input 85V~264VAC
Soft start and PWM control circuit design effectively reduce impact on the power grid
-30℃~+70℃ extreme operating temperature, no derating at low temperatures, easily cope with various environments
03 Flexible Application
LED indicator for power supply start-up, clearly showing the product's working status
30mm thin design, lightweight and compact, saving space
Detail Parameters
| Parameter Category | Parameter Item | Parameter Value |
|---|
| 4.1 Main Technical Parameters | Rated Output Power | 15W |
| Output Voltage | 12V |
| Ripple and Noise | ≤150mV |
| Output Voltage Stability | ±1.5% |
| Load Stability | ±1% |
| Voltage Adjustment Range | ±10% |
| Hold Time | >12ms |
| Input Voltage Range | 85VAC-264VAC |
| Frequency Range | 47-63Hz |
| Efficiency | 85.9% |
| AC Current | 0.35A/110VAC 0.25A/220VAC |
| Surge Current | Cold Start 45A/220VAC |
| Overcurrent Protection | 105%-150% of Rated Output Current Mode: Auto-recovery after abnormality elimination |
| Overvoltage Protection | 105%-150% of Rated Output Voltage Mode: Output Shutdown, Restart Recovery |
| Short Circuit Protection | Mode: Auto-recovery after abnormality elimination |
| Overtemperature Protection | / |
| Pollution Degree | 2 |
| Overvoltage Level | II Level |
| Dielectric Strength | I/P-O/P: 3kVAC |
| | I/P-FG: 1.5kVAC |
| | O/P-FG: 0.5kVAC |
| Insulation Resistance | > 100MΩ |
| EMC Emission | Class A |
| Rated Output Power | 35W |
| Output Voltage | 12V |
| Ripple and Noise | ≤150mV |
| Output Voltage Stability | ±1.5% |
| Load Stability | ±1% |
| Voltage Adjustment Range | ±10% |
| Hold Time | >12ms |
| Input Voltage Range | 85VAC-264VAC |
| Frequency Range | 47-63Hz |
| Efficiency | 86.5% |
| AC Current | 0.7A/110VAC 0.42A/220VAC |
| Surge Current | Cold Start 45A/220VAC |
| Overcurrent Protection | 105%-150% of Rated Output Current Mode: Auto-recovery after abnormality elimination |
| Overvoltage Protection | 105%-150% of Rated Output Voltage Mode: Output Shutdown, Restart Recovery |
| Short Circuit Protection | Mode: Auto-recovery after abnormality elimination |
| Overtemperature Protection | / |
| Pollution Degree | 2 |
| Overvoltage Level | II Level |
| Dielectric Strength | I/P-O/P: 3kVAC |
| | I/P-FG: 1.5kVAC |
| | O/P-FG: 0.5kVAC |
| Insulation Resistance | > 100MΩ |
| EMC Emission | Class A |
| Rated Output Power | 50W |
| Output Voltage | 12V |
| Ripple and Noise | ≤150mV |
| Output Voltage Stability | ±1.5% |
| Load Stability | ±1% |
| Voltage Adjustment Range | ±10% |
| Hold Time | >12ms |
| Input Voltage Range | 85VAC-264VAC |
| Frequency Range | 47-63Hz |
| Efficiency | 87.6% |
| AC Current | 0.95A/110VAC 0.56A/220VAC |
| Surge Current | Cold Start 45A/220VAC |
| Overcurrent Protection | 105%-150% of Rated Output Current Mode: Auto-recovery after abnormality elimination |
| Overvoltage Protection | 105%-150% of Rated Output Voltage Mode: Output Shutdown, Restart Recovery |
| Short Circuit Protection | Mode: Auto-recovery after abnormality elimination |
| Overtemperature Protection | / |
| Pollution Degree | 2 |
| Overvoltage Level | II Level |
| Dielectric Strength | I/P-O/P: 3kVAC |
| | I/P-FG: 1.5kVAC |
| | O/P-FG: 0.5kVAC |
| Insulation Resistance | > 100MΩ |
| EMC Emission | Class A |
| Rated Output Power | 75W |
| Output Voltage | 12V |
| Ripple and Noise | ≤150mV |
| Output Voltage Stability | ±1.5% |
| Load Stability | ±1% |
| Voltage Adjustment Range | ±10% |
| Hold Time | >12ms |
| Input Voltage Range | 85VAC-264VAC |
| Frequency Range | 47-63Hz |
| Efficiency | 87.6% |
| AC Current | 1.4A/110VAC 0.85A/220VAC |
| Inrush Current | Cold Start 45A/220VAC |
| Overcurrent Protection | 105%-150% of Rated Output Current Mode: Auto Recovery after Abnormality |
| Overvoltage Protection | 105%-150% of Rated Output Voltage Mode: Output Off, Restart Recovery |
| Short Circuit Protection | Mode: Auto Recovery after Abnormality |
| Overtemperature Protection | / |
| Pollution Degree | 2 |
| Overvoltage Category | II |
| Dielectric Strength | I/P-O/P: 3kVAC |
| | I/P-FG: 1.5kVAC |
| | O/P-FG: 0.5kVAC |
| Insulation Resistance | > 100MΩ |
| EMC Emission | Class A |
| Rated Output Power | 100W |
| Output Voltage | 12V |
| Ripple and Noise | ≤150mV |
| Output Voltage Stability | ±1.5% |
| Load Stability | ±1% |
| Voltage Adjustment Range | ±10% |
| Hold Time | >12ms |
| Input Voltage Range | 85VAC-264VAC |
| Frequency Range | 47-63Hz |
| Efficiency | 88.3% |
| AC Current | 1.9A/110VAC 1.2A/220VAC |
| Inrush Current | Cold Start 60A/220VAC |
| Overcurrent Protection | 105%-150% of Rated Output Current Mode: Auto Recovery after Abnormality |
| Overvoltage Protection | 105%-150% of Rated Output Voltage Mode: Output Off, Restart Recovery |
| Short Circuit Protection | Mode: Auto Recovery after Abnormality |
| Overtemperature Protection | 95℃ Protection Mode: Output Voltage Off, Restart Recovery after Abnormality |
| Pollution Degree | 2 |
| Overvoltage Category | II |
| Dielectric Strength | I/P-O/P: 3kVAC |
| | I/P-FG: 1.5kVAC |
| | O/P-FG: 0.5kVAC |
| Insulation Resistance | > 100MΩ |
| EMC Emission | Class A |
| Rated Output Power | 150W |